@ARTICLE{Huiqing_Pan_An_2010, author={Huiqing Pan and Shulin Tian and Peng Ye}, number={No 3}, journal={Metrology and Measurement Systems}, pages={405-414}, howpublished={online}, year={2010}, publisher={Polish Academy of Sciences Committee on Metrology and Scientific Instrumentation}, abstract={In a parallel time-interleaved data sampling system, timing and amplitude mismatches of this structure degrade the performance of the whole ADC system. In this paper, an adaptive blind synthesis calibration algorithm is proposed, which could estimate the timing, gain and offset errors simultaneously, and calibrate automatically. With no need of an extra calibration signal and redesign, it could efficiently and dynamically track the changes of mismatches due to aging or temperature variation. A fractional delay filter is developed to adjust the timing mismatch, which simplifies the design and decreases the cost. Computer simulations are also included to demonstrate the effectiveness of the proposed method.}, type={Artykuły / Articles}, title={An Adaptive Synthesis Calibration Method for Time-Interleaved Sampling Systems}, URL={http://journals.pan.pl/Content/107060/PDF/Journal10178-VolumeXVII%20Issue3_08%20paper.pdf}, doi={10.2478/v10178-010-0034-4}, keywords={time-interleaved sampling, channel mismatch, nonuniform, adaptive}, }