@ARTICLE{Tomczuk_Krzysztof_A_2013, author={Tomczuk, Krzysztof}, number={No 4}, journal={Metrology and Measurement Systems}, pages={667-676}, howpublished={online}, year={2013}, publisher={Polish Academy of Sciences Committee on Metrology and Scientific Instrumentation}, abstract={A high pressure resonator transducer (0 to 100 MPa) devised by the author has been described. The elastic element of the converter consists of a cylinder with an offset arranged axis hole. Quartz resonators were used for the measurement of deformations of the pipe. Based upon the results of the transducer testing, a new algorithmic method for the minimizalizsation of the temperature error, that eliminates the need for a temperature gauge has been worked out.}, type={Artykuły / Articles}, title={A High Pressure Resonator Transducer with a Programmed Correction of Static Characteristics}, URL={http://journals.pan.pl/Content/90204/PDF/Journal10178-VolumeXX%20Issue4_13.pdf}, doi={10.2478/mms-2013-0057}, keywords={pressure transducer, quartz resonator, algorithmic correction}, }