@ARTICLE{Kotowicz_Janusz_Supercritical_2013, author={Kotowicz, Janusz and Dryjańska, Aleksandra}, number={No 3 September}, journal={Archives of Thermodynamics}, pages={123-136}, howpublished={online}, year={2013}, publisher={The Committee of Thermodynamics and Combustion of the Polish Academy of Sciences and The Institute of Fluid-Flow Machinery Polish Academy of Sciences}, abstract={This article describes a thermodynamic analysis of an oxy type power plant. The analyzed power plant consists of: 1) steam turbine for supercritical steam parameters of 600 °C/29 MPa with a capacity of 600 MW; 2) circulating fluidized bed boiler, in which brown coal with high moisture content (42.5%) is burned in the atmosphere enriched in oxygen; 3) air separation unit (ASU); 4) CO2 capture installation, where flue gases obtained in the combustion process are compressed to the pressure of 150 MPa. The circulated fluidized bed (CFB) boiler is integrated with a fuel dryer and a cryogenic air separation unit. Waste nitrogen from ASU is heated in the boiler, and then is used as a coal drying medium. In this study, the thermal efficiency of the boiler, steam cycle thermal efficiency and power demand were determined. These quantities made possible to determine the net efficiency of the test power plant.}, type={Artykuły / Articles}, title={Supercritical power plant 600 MW with cryogenic oxygen plant and CCS installation}, URL={http://journals.pan.pl/Content/94434/PDF/08_paper.pdf}, doi={10.2478/aoter-2013-0019}, keywords={CFB oxy boiler, Oxy-combustion system, Supercritical oxy power plant, Electricity generation efficiency, Cryogenic air separation}, }