TY - JOUR N2 - In this paper the authors present the test carried out to obtain the uniform velocity distribution at the outlet cross section of flow fan. In the investigations the inner flat vane mounted inside of the impeller has been applied. For various angular position of the inner vane, one obtained different flow structures as well as different velocity distributions. The analysis of the obtained results is presented in form of graphs shown in 10 figures, juxtaposing flow phenomena with velocity distributions. Numerical flow simulation with the use of Flo++ program based on the Finite Volume Method was carried out. L1 - http://journals.pan.pl/Content/115391/PDF/AME_2009_132088.pdf L2 - http://journals.pan.pl/Content/115391 PY - 2009 IS - No 1 EP - 72 DO - 10.24425/ame.2009.132088 KW - cross flow fan KW - the finite volume methods KW - uniform velocity distribution A1 - Stacharska-Targosz, Jolanta A1 - Chmielowiec, Monika PB - Polish Academy of Sciences, Committee on Machine Building VL - vol. 56 DA - 2009 T1 - The influence of internal vane on uniform velocity distribution in the cross-flow fan SP - 61 UR - http://journals.pan.pl/dlibra/publication/edition/115391 T2 - Archive of Mechanical Engineering ER -