Details

Title

Can historic interiors with large cubature be turned acoustically correct?

Journal title

Archives of Acoustics

Yearbook

2016

Volume

vol. 41

Numer

No 1

Publication authors

Keywords

room acoustics; acoustic rehabilitation of historic interiors; Schroeder diffusers; microperforated foil

Divisions of PAS

Nauki Techniczne

Description

Archives of Acoustics is an English-language peer-reviewed quarterly journal publishing original research papers from all areas of acoustics and abstracts from some specialised acoustical conferences. It gives free internet access to its full content (abstracts of research papers) to current issues.

Archives of Acoustics, the peer-reviewed quarterly journal publishes original research papers from all areas of acoustics like:

  • acoustical measurements and instrumentation,
  • acoustics of musics,
  • acousto-optics,
  • architectural, building and environmental acoustics,
  • bioacoustics,
  • electroacoustics,
  • linear and nonlinear acoustics,
  • noise and vibration,
  • physical and chemical effects of sound,
  • physiological acoustics,
  • psychoacoustics,
  • quantum acoustics,
  • speech processing and communication systems,
  • speech production and perception,
  • transducers,
  • ultrasonics,
  • underwater acoustics.

Earlier issues are available on the old website http://acoustics.ippt.gov.pl/index.php/aa/issue/archive

Abstract

Historic interiors with large cubature, such as reception, theatrical, and concert halls, need to be renovated periodically if they are to be preserved as cultural heritage for future generations. In such cases it is necessary to maintain appropriate balance between requirements imposed by heritage conservation authorities office which are usually being given a higher priority, applicable safety regulations, and the comfort of use, including good acoustics. The paper is a presentation of architectural interference in three historic interiors with large cubature leading to changes in their acoustic qualities. In two cases, the changes were beneficial to the functional qualities of the halls to satisfaction of the investors carrying out the renovation work. In the third instance, the architectural interference aimed at showing off the monumental valor of the interior resulted in significant degradation of its acoustics. To remedy the situation impairing the functional program of the facility, corrective measures are proposed neutral with respect to its historic character.

Publisher

Committee on Acoustics PAS, PAS Institute of Fundamental Technological Research, Polish Acoustical Society

Identifier

ISSN 0137-5075 ; eISSN 2300-262X

DOI

10.1515/aoa-2016-0001

×