Details

Title

Measurement and Analysis of Partial Discharge using an Ultra-High Frequency Sensor for Gas Insulated Structures

Journal title

Metrology and Measurement Systems

Yearbook

2017

Volume

vol. 24

Issue

No 3

Authors

Keywords

gas insulated structures ; partial discharge ; ultra-high frequency sensor ; conversion

Divisions of PAS

Nauki Techniczne

Coverage

515–524

Publisher

Polish Academy of Sciences Committee on Metrology and Scientific Instrumentation

Date

2017.09.30

Type

Artykuły / Articles

Identifier

DOI: 10.1515/mms-2017-0045 ; ISSN 2080-9050, e-ISSN 2300-1941

Source

Metrology and Measurement Systems; 2017; vol. 24; No 3; 515–524

References

Jo (null), Comparison of partial discharge characteristics in gas under, Trans Electr Electron Mater, 16, 2015. ; (2007), guide for the detection and location of acoustic emission from partial discharges in oil - immersed power transformers and reactors, IEEE IEEE, 13. ; Ryan (2013), High - voltage testing The Institution of Technology, engineering Engineering, 319. ; Neumann (2000), measurements on GIS of different designs by non - conventional UHF sensors session, null, 15, 305. ; Masud (2014), Application of an ensemble neural network for classifying partial discharge patterns, Power Syst Res, 24, 110. ; Gill (2008), Electrical power equipment maintenance and testing, null, 1. ; Muhamad (2011), Dissolved gas analysis for common transformer faults in soy seed - based oil, IET Power Appl, 17, 133. ; Okabe (2014), New aspects of UHF PD diagnostics on gas - insulated systems, IEEE Trans Elect, 21, 2245. ; Haddad (2004), Advances in high voltage engineering The Institution of Technology, Engineering, 1. ; Zhu (2016), Classification and separation of partial discharge ultra - high - frequency signals in a kV gas insulated substation by using cumulative energy technique, IET Sci Meas Technol, 18, 252. ; Wang (2014), Research on a practical de - nosing method and the characterization of partial discharge UHF signals, IEEE Trans Elect, 20, 2206. ; Kim (2009), Measurements and analysis of the acoustic signals produced by partial discharge in insulation oil, Curr Appl Phys, 15, 296. ; Hekmati (2016), novel acoustic method of partial discharge allocation considering structure - borne waves, Int J Electr Power Energy Syst, 14, 77. ; Vedral (2010), processing in partial discharge measurement, Signal Meas Syst, 12, 22. ; Sahoo (2005), Trends in partial discharge pattern classification survey, IEEE Trans Elect, 23, 248. ; (2009), Compact and reliable Decades of benefits : Gas - insulated switchgear from to kV Technology magazine, null, 1. ; Raja (2002), Recognition of discharge sources using signatures, IEEE Elect Mag, 19, 8. ; Neumann (2012), End of life estimation and optimisation of maintenance of HV switchgear and GIS substations session, null, 202. ; CIGER (2013), Risk assessment on defects in GIS based on PD Diagnosis, null, 22. ; Kreuger (1990), Partial discharge detection in high - voltage equipment, null, 11, 29.
×