Search results

Filters

  • Journals
  • Authors
  • Keywords
  • Date
  • Type

Search results

Number of results: 6
items per page: 25 50 75
Sort by:

Abstract

The paper presents the problem of sensorless control of a permanent magnets synchronous motor (PMSM) without a damping cage for fan applications. Frequency control was used according to the principle of v/f = const. In order to reduce the power consumption of the drive system, the optimal voltage to the motor frequency characteristics was tested in the laboratory. The experimental studies was performed on a laboratory set of a drive consisting of two coupled PMSM machines, where one machine was supplied by a transistor inverter and the other was a passive load. A new criterion based on minimizing the module of stator current vector was proposed and an optimization algorithm in steady states was tested. The results of laboratory tests confirmed the validity of the applied solution for the fan drive.
Go to article

Abstract

The single-phase voltage loss is a common fault. Once the voltage-loss failure occurs, the amount of electrical energy will not be measured, but it is to be calculated so as to protect the interest of the power supplier. Two automatic calculation methods, the power substitution and the voltage substitution, are introduced in this paper. Considering the lack of quantitative analysis of the calculation error of the voltage substitution method, the grid traversal method and MATLAB tool are applied to solve the problem. The theoretical analysis indicates that the calculation error is closely related to the voltage unbalance factor and the power factor, and the maximum calculation error is about 6% when the power system operates normally. To verify the theoretical analysis, two three-phase electrical energy metering devices have been developed, and verification tests have been carried out in both the lab and field conditions. The lab testing results are consistent with the theoretical ones, and the field testing results show that the calculation errors are generally below 0.2%, that is correct in most cases.
Go to article

Abstract

Basing on the first and second law of thermodynamics the fundamental trends in the Polish energy policy are analysed, including the aspects of environmental protection. The thermodynamical improvement of real processes (reduction of exergy losses) is the main way leading to an improvement of the effectivity of energy consumption. If the exergy loss is economically not justified, we have to do with an error from the viewpoint of the second law analysis. The paper contains a thermodynamical analysis of the ratio of final and primary energy, as well as the analysis of the thermo-ecological cost and index of sustainable development concerning primary energy. Analyses of thermo-ecological costs concerning electricity and centralized heat production have been also carried out. The effect of increasing the share of high-efficiency cogeneration has been analyzed, too. Attention has been paid to an improved efficiency of the transmission and distribution of electricity, which is of special importance from the viewpoint of the second law analysis. The improvement of the energy effectivity in industry was analyzed on the example of physical recuperation, being of special importance from the point of view of exergy analysis.
Go to article

Abstract

Oxy-fuel combustion (OFC) belongs to one of the three commonly known clean coal technologies for power generation sector and other industry sectors responsible for CO2emissions (e.g., steel or cement production). The OFC capture technology is based on using high-purity oxygen in the combustion process instead of atmospheric air. Therefore flue gases have a high concentration of CO2- Due to the limited adiabatic temperature of combustion some part of CO2must be recycled to the boiler in order to maintain a proper flame temperature. An integrated oxy-fuel combustion power plant constitutes a system consisting of the following technological modules: boiler, steam cycle, air separation unit, cooling water and water treatment system, flue gas quality control system and CO2processing unit. Due to the interconnections between technological modules, energy, exergy and ecological analyses require a system approach. The paper present the system approach based on the 'input-output' method to the analysis of the: direct energy and material consumption, cumulative energy and exergy consumption, system (local and cumulative) exergy losses, and thermoecological cost. Other measures like cumulative degree of perfection or index of sustainable development are also proposed. The paper presents a complex example of the system analysis (from direct energy consumption to thermoecological cost) of an advanced integrated OFC power plant.
Go to article

Abstract

In the complex RLC network, apart from the currents flows arising from the normal laws of Kirchhoff, other distributions of current, resulting from certain optimization criteria, may also be received. This paper is the development of research on distribution that meets the condition of the minimum energy losses within the network called energy-optimal distribution. Optimal distribution is not reachable itself, but in order to trigger it off, it is necessary to introduce the control system in current-dependent voltage sources vector, entered into a mesh set of a complex RLC network. For energy-optimal controlling, to obtain the control operator, the inversion of R(s) operator is required. It is the matrix operator and the dispersive operator (it depends on frequency). Inversion of such operators is inconvenient because it is algorithmically complicated. To avoid this the operator R(s) is replaced by the R’ operator which is a matrix, but non-dispersive one (it does not depend on s). This type of control is called the suboptimal control. Therefore, it is important to make appropriate selection of the R’ operator and hence the suboptimal control. This article shows how to implement such control through the use of matrix operators of multiple differentiation or integration. The key aspect is the distribution of a single rational function H(s) in a series of ‘s’ or ‘s⁻¹’. The paper presents a new way of developing a given, stable rational transmittance with real coefficients in power series of ‘s/s⁻¹՚. The formulas to determine values of series coefficients (with ‘s/s⁻¹’) have been shown and the conditions for convergence of differential/integral operators given as series of ‘s/s⁻¹’ have been defined.
Go to article

Abstract

A contactless energy transmission system is essential to supply onboard systems of electromagnetically levitated vehicles without physical contact to the guide rail. One of the possibilities to realise a contactless power supply (CPS) is by integrating the primary actuator into the guide rail of an electromagnetic guiding system (MGS). The secondary actuator is mounted on the elevator car. During the energy transmission, load dependent non-linear losses occur in the guide rail. The additional losses, which are caused by the leakage flux penetrating into the guide rail, cannot be modelled using the classical approach of iron losses in the equivalent circuit of a transformer, which is a constant parallel resistance to the mutual inductance. This paper introduces an approach for modelling the load dependent non-linear losses occurring in the guide rail using additional variable discrete circuit elements.
Go to article