Search results

Filters

  • Journals
  • Authors
  • Keywords
  • Date
  • Type

Search results

Number of results: 14
items per page: 25 50 75
Sort by:

Abstract

Specific requirements are designed and implemented in electronic and telecommunication systems for received signals, especially high-frequency ones, to examine and control the signal radiation. However, as a serious drawback, no special requirements are considered for the transmitted signals from a subsystem. Different industries have always been struggling with electromagnetic interferences affecting their electronic and telecommunication systems and imposing significant costs. It is thus necessary to specifically investigate this problem as every device is continuously exposed to interferences. Signal processing allows for the decomposition of a signal to its different components to simulate each component. Radiation control has its specific complexities in systems, requiring necessary measures from the very beginning of the design. This study attempted to determine the highest radiation from a subsystem by estimating the radiation fields. The study goal was to investigate the level of radiations received and transmitted from the adjacent systems, respectively, and present methods for control and eliminate the existing radiations. The proposed approach employs an algorithm which is based on multi-component signals, defect, and the radiation shield used in the subsystem. The algorithm flowchart focuses on the separation and of signal components and electromagnetic interference reduction. In this algorithm, the detection process is carried out at the bounds of each component, after which the separation process is performed in the vicinity of the different bounds. The proposed method works based on the Fourier transform of impulse functions for signal components decomposition that was employed to develop an algorithm for separation of the components of the signals input to the subsystem.
Go to article

Abstract

When two pure tones of slightly different frequency are presented separately to each ear, the listener perceives a third single tone with amplitude variations at a frequency that equals the difference between the two tones; this perceptual illusion is known as the binaural auditory beat (BB). There are anecdotal reports that suggest that the binaural beat can entrain EEG activity and may affect the arousal levels, although few studies have been published. There is a need for double-blind, well-designed studies in order to establish a solid foundation for these sounds, as most of the documented benefits come from self-reported cases that could be affected by placebo effect. As BBs are a cheap technology (it even exists a free open source programmable binaural- beat generator on the Internet named Gnaural), any achievement in this area could be of public interest. The aim in our research was to explore the potential of BBs in a particular field: tasks that require focus and concentration. In order to detect changes in the brain waves that could relate to any particular improvement, EEG recordings of a small sample of individuals were also obtained. In this study we compare the effect of different binaural stimulation in 7 EEG frequency ranges. 78 participants were exposed to 20-min binaural beat stimulation. The effects were obtained both quali- tative with cognitive test and quantitative with EEG analysis. Results suggest no significant statistical improvement in 20-min stimulation.
Go to article

Abstract

Simultaneous propagation of vibrations and noise has an important role in the task of minimizing vibroacoustic hazards on the station of operator of the construction machinery. In many cases vibrations transferred by the construction are processed to noise in different points of the machine. As a result, they may increase the level of noise at the workplace. The paper presents the proposition of a simple estimation of noise and vibration propagation paths of the machine. On the basis of the analysis of hydraulic excavator an effectiveness of a proposed procedure was shown. This procedure helps to minimize the transfer of vibrations of power unit in selected frequency ranges which led to the change of overall noise level in operator’s cab about 5 dB.
Go to article

Abstract

The paper presents theoretical and experimental analyses of a possible effect of the short-circuit forces on the transformer winding. The first part of the paper is focused on creation and activity of the radial and axial forces during a short circuit. It shows dimensions, direction and − of course − the resulting mechanical stress. The presented equation shows basic dependencies of these mechanical forces created in the transformer winding. Finally, the paper presents experimental methods of diagnosing and analysing the effects of short-circuit forces on the transformer winding.
Go to article

Abstract

This paper presents the measurement of vibrational properties of sundatang soundboard. Sundatang is a plucked stringed traditional musical instrument that is popular among the Kadazandusun communities in Sabah, Malaysia. The vibrational properties of the soundboard are measured using CADA-X impact hammering system in a condition where the instrument is without any string. There are two types of sundatang used in this study; one made from acacia and the other from vitex wood. In this measurement, frequency response functions (FRFs) and modal parameters of the top plate and back plate of this instrument are obtained. It is found that in free edge, fundamental frequency of both plates of acacia sundatang is greater than the vitex sundatang in a range of 112 Hz to 230 Hz. However, in clamped edge (attached to its ribs), it was modified to a lower frequency and closer to each other in the range of 55 Hz to 59 Hz. Another finding is the detection of the excitation of similar mode shape at different resonance frequencies. This phenomenon is termed as Different State of Mode (DSM) which is observed may be because the number of testing points is not enough. Findings of this study provide important information to the study of quality development of this instrument
Go to article

Abstract

This paper presents the method of analysis of parametric systems in frequency domain. These systems are also referred to as linear time varying systems (LTV). The article includes a description of an analytical method for determining the frequency response of the first order parametric circuit with non-periodically variable parameters. The results have been illustrated by an example.
Go to article

Abstract

A new method for determining optimum dimension ratios for small rectangular rooms has been presented. In a theoretical model, an exact description of the room impulse response was used. Based on the impulse response, a frequency response of a room was calculated to find changes in the sound pressure level over the frequency range 20–200 Hz. These changes depend on the source and receiver positions, thus, a new metric equivalent to an average frequency response was introduced to quantify the overall sound pressure variation within the room for a selected source position. A numerical procedure was employed to seek a minimum value of the deviation of the sound pressure level response from a smooth fitted response determined by the quadratic polynomial regression. The most smooth frequency responses were obtained when the source was located at one of the eight corners of a room. Thus, to find the best possible dimension ratios, in the numerical procedure the optimal source position was assumed. Calculation results have shown that optimum dimension ratios depend on the room volume and the sound damping inside a room, and for small and medium volumes these ratios are roughly 1 : 1.48 : 2.12, 1 : 1.4 : 1.89 and 1 : 1.2 : 1.45. When the room volume was suitably large, the ratio 1 : 1.2 : 1.44 was found to be the best one.
Go to article

Abstract

In this work, an approach to the design of broadband thickness-mode piezoelectric transducer is pre- sented. In this approach, simulation of discrete time model of the impulse response of matched and backed piezoelectric transducer is used to design high sensitivity, broad bandwidth, and short-duration impulse response transducers. The effect of matching the performance of transmitting and receiving air backed PZT-5A transducer working into water load is studied. The optimum acoustical characteristics of the quarter wavelength matching layers are determined by a compromise between sensitivity and pulse duration. The thickness of bonding layers is smaller than that of the quarter wavelength matching layers so that they do not change the resonance peak significantly. Our calculations show that the −3 dB air backed transducer bandwidth can be improved considerably by using quarter wavelength matching layers. The computer model developed in this work to predict the behavior of multilayer structures driven by a transient waveform agrees well with measured results. Furthermore, the advantage of this this model over other approaches is that the time signal for optimum set of matching layers can be predicted rapidly
Go to article

Abstract

The equipment mounted on the carbody chassis of the railway vehicles is a critical component of the vehicle in terms of ride comfort. The reason for that is their large mass, able to visibly influence the vibrations mode of the carbody. The paper examines the influence of the equipment upon the mode of vertical vibrations of the carbody in the high-speed vehicles, reached on the basis of the frequency response functions of the acceleration in three carbody reference points – at the centre and above the bogies. These functions are derived from the numerical simulations developed on a rigid-flexible coupled model, with seven degrees of freedom. As a rule, the results herein prove the influence of the equipment mounting mode (rigid or elastic), along with the speed regime, upon the level of vibrations in the carbody reference points, at the resonance frequency of the symmetrical bending mode. Similarly, it is also demonstrated how the equipment mass and the damping degree of the suspension system affect the level of the vibrations in the carbody.
Go to article

Abstract

One of important methods used for diagnostics of a transformer’s active part is Frequency Response Analysis (FRA). It allows to determine the mechanical condition of windings, their displacements, deformations and electric faults, as well as some problems with internal leads and connections, core and bushings. Still pending problem is interpretation of measurements results. One of approaches is application of computer modeling to simulate various failure modes and connected with them changes in FRA response. The paper presents two types of models, one based on lumped parameters with RLC elements, and one based on distributed parameters with TLM method. Both methods give similar results, comparable to real measurements of simulated coil.
Go to article

Abstract

Transformers are one of the most important components of the power system. It is important to maintain and assess the condition. Transformer lifetime depends on the life of its insulation and insulation life is also strongly influenced by moisture in the insulation. Due to importance of this issue, in this paper a new method is introduced for determining the moisture content of the transformer insulation system using dielectric response analysis in the frequency domain based on artificial bee colony algorithm. First, the master curve of dielectric response is modeled. Then, using proposed method the master curve and the measured dielectric response curves are compared. By analyzing the results of the comparison, the moisture content of paper insulation, electrical conductivity of the insulating oil and dielectric model dimensions are determined. Finally, the proposed method is applied to several practical samples to demonstrate its capabilities compared with the well-known conventional method.
Go to article

Abstract

Estimating the fundamental frequency and harmonic parameters is basic for signal modelling in a power supply system. Differing from the existing parameter estimation algorithms either in power quality monitoring or in harmonic compensation, the proposed algorithm enables a simultaneous estimation of the fundamental frequency, the amplitudes and phases of harmonic waves. A pure sinusoid is obtained from an input multiharmonic input signal by finite-impulse-response (FIR) comb filters. Proposed algorithm is based on the use of partial derivatives of the processed signal and the weighted estimation procedure to estimate the fundamental frequency, the amplitude and the phase of a multi-sinusoidal signal. The proposed algorithm can be applied in signal reconstruction, spectral estimation, system identification, as well as in other important signal processing problems. The simulation results verify the effectiveness of the proposed algorithm.
Go to article

Abstract

Long transmission lines have to be compensated to enhance the transport of active power. But a wrong design of the compensation may lead to subsynchronous resonances (SSR). For studies often park equivalent circuits are used. The parameters of the models are often determined analytically or by a three-phase short-circuit test. Models with this parameters give good results for frequencies of 50 Hz and 100 Hz resp. 60 Hz and 120 Hz. But SSR occurs at lower frequencies what arises the question of the reliability of the used models. Therefore in this publication a novel method for the determination of Park equivalent circuit parameters is presented. Herein the parameters are determined form time functions of the currents and the electromagnetic moment of the machine calculated by transient finite-element simulations. This parameters are used for network simulations and compared with the finite-element calculations. Compared to the parameters derived by a three-phase short-circuit a significant better accuracy of simulation results can be achieved by the presented method.
Go to article

This page uses 'cookies'. Learn more