Search results

Filters

  • Journals
  • Authors
  • Date
  • Type

Search results

Number of results: 4
items per page: 25 50 75
Sort by:
Download PDF Download RIS Download Bibtex

Abstract

The Lower Devonian ‘Placoderm Sandstone’ in the Holy Cross Mountains (HCM) is filled with abundant impressions

of disarticulated vertebrate remains. The only acanthodian macroremains named to date are fin spines

of Machaeracanthus polonicus Gürich. Fin spine impressions in slabs from the Winna Formation (Emsian) at

Podłazie Hill (near Daleszyce) in the southern HCM, and also the Barcza Formation (?Lochkovian) at Barcza

Quarry, Miedziana Góra Conglomerate (?Lochkovian), Gruchawka, and Zagórze Formation (middle–upper

Emsian) at Bukowa Mountain in the northern HCM, reposited in the University of Warsaw, Polish Geological

Institute-National Research Institute, Warsaw, and Natural History Museum, London collections, have been cast

and studied in order to better document this poorly known taxon. As noted in other Machaeracanthus species,

we have found that M. polonicus has two different morphotypes of spines, which abut lengthwise to form a pair

of spines. Our investigations show that the fin spine assemblage includes Onchus overathensis as well as M.

polonicus, and probably another undetermined acanthodian. The affinities of O. overathensis are reassessed.

It is here considered to be a diplacanthiform, and reassigned to the genus Striacanthus, as S. overathensis.

Acanthodian scapulocoracoids have also been identified, as well as tightly spiralled toothwhorls which could

be from an acanthodian.

Go to article

Authors and Affiliations

Carole J. Burrow
Szrek Piotr
Download PDF Download RIS Download Bibtex

Abstract

In this paper, a discrete wavelet transform (DWT) based approach is proposed for power system frequency estimation. Unlike the existing frequency estimators mainly used for power system monitoring and control, the proposed approach is developed for fundamental frequency estimation in the field of energy metering of nonlinear loads. The characteristics of a nonlinear load is that the power signal is heavily distorted, composed of harmonics, inter-harmonics and corrupted by noise. The main idea is to predetermine a series of frequency points, and the mean value of two frequency points nearest to the power system frequency is accepted as the approximate solution. Firstly the input signal is modulated with a series of modulating signals, whose frequencies are those frequency points. Then the modulated signals are decomposed into individual frequency bands using DWT, and differences between the maximum and minimum wavelet coefficients in the lowest frequency band are calculated. Similarities among power system frequency and those frequency points are judged by the differences. Simulation results have proven high immunity to noise, harmonic and inter-harmonic interferences. The proposed method is applicable for real-time power system frequency estimation for electric energy measurement of nonlinear loads.

Go to article

Authors and Affiliations

Zhang Peng
Hong-Bin Li
Download PDF Download RIS Download Bibtex

Abstract

The paper describes a prototype operator panel, which was designed to operate with the S7-200 family of Programmable Logic Controllers (PLC-s) from Siemens. Most of the functionality of the operator panel was implemented in a computer program, which runs on a PC-class computer. The program communicates with a PLC through its communication port configured in the Freeport mode. Two kinds of interface between the PC, and the PLC are supported: wired, and wireless. For wired connection a standard PC/PPI cable supplied by Siemens is used. For wireless connection two communication modules were designed, which operate in the free 433 MHz band. The operator panel program is intuitive, and easy to use. States of PLC inputs and outputs are presented using graphical objects. It is possible to modify states of the outputs, and monitor and edit any variable in the M and V memory in the PLC. The application supports also alarming. The program can be run on any computer with the MS Windows operating system installed. This makes the solution very cost-effective. Providing both wired and wireless communication radically increases flexibility of the proposed solution. The panel can be quickly mounted in areas, where pulling new cables is inconvenient, difficult or expensive.

Go to article

Authors and Affiliations

Kacper Mazek
Mirosław Chmiel
Józef Kulisz
Download PDF Download RIS Download Bibtex

Abstract

Przegląd literaturowy stosowanych na świecie technologii do przerobu stopów Zn-Ag-Pb wskazuje, że najefektywniejszą technologią jest metoda destylacji próżniowej, oparta na zjawiskach parowania lotnych składników z kąpieli metalicznej. W procesie odparowania składników z ciekłych stopów, w warunkach obniżonego ciśnienia, podstawowe znaczenie odgrywają zjawiska transportu masy. Badania procesu parowania w próżni wykazują, że jego szybkość może być zwiększona nie tylko przez obniżenie ciśnienia czy wzrost temperatury procesu, lecz także przez zmianę warunków hydrodynamicznych w układzie. Można także przypuszczać, że w zależności od rodzaju stopu kontrola kinetyczna omawianego procesu jest znacznie zróżnicowana. Wykazanie, który z tych czynników najistotniej wpływa na kinetykę procesu parowania, wymaga określenia etapu kontrolującego proces, a także określenia wpływu tych czynników na zmianę jego kontroli. W ramach pracy przeprowadzono badania próżniowego oddestylowania cynku ze stopów Zn-Ag-Pb w zakresie ciśnień od I do 1000 Pa i temperatur od 823 do 898 K. Badania przeprowadzono dla stopu o składzie chemicznym: 50,0% Ag, 35,0% Pb i 15,0% Zn. Podstawowym urządzeniem wykorzystywanym w badaniach był agregat próżniowy składający się z głowicy roboczej, pieca indukcyjnego PIS O I TR i układu pomp próżniowych SP2000 PA. Po każdym doświadczeniu określano wielkość ubytku masy próbki oraz analizowano skład chemiczny stopu oznaczając zawartość: cynku, srebra i ołowiu metodą atomowej spektrometrii absorpcyjnej (AAS) z zastosowaniem spektrometru firmy Perkin-Elmer model 603. Na podstawie analizy uzyskanych wartości podstawowych parametrów kinetycznych: gęstości strumienia masy oraz współczynnika przenikania masy dla zakresu ciśnień od IO do 20 Pa obserwuje się silną zależność tych wielkości od ciśnienia panującego w układzie pomiarowym. Oznacza to, że w tym zakresie ciśnień następuje zmiana kontroli procesu i opory w fazie gazowej nakładają się na opory w fazie ciekłej. Można więc przyjąć, że w obszarze ciśnień od IO do 20 Pa mamy do czynienia z mieszaną kontrolą procesu. W zakresie ciśnień powyżej 20 Pa można natomiast przyjąć, że proces zachodzi w obszarze dyfuzyjnym i jest kontrolowany oporami w fazie gazowej. Szybkość procesu odcynkowania stopów Zn-Ag-Pb wzrasta silniej w miarę obniżania ciśnienia niż przy wzroście temperatury. W zakresie ciśnień poniżej IO Pa, wartości pozornej energii aktywacji procesu zbliżone są do wartości energii aktywacji dyfuzji cynku w ciekłym srebrze. Stanowi to potwierdzenie faktu, że w tym zakresie ciśnień proces destylacji cynku kontrolowany jest głównie transportem masy w fazie ciekłej.
Go to article

Authors and Affiliations

Jerzy Łabaj
Jan Botor
Remogiusz Sosnowski

This page uses 'cookies'. Learn more