This paper presents a comparison of three surface condenser connection setups on the cooling water side. Four connections were considered, namely serial, mixed and two parallel ones. The analysis was conducted based on the calculated heat balances of proposed power unit for nominal and not nominal parameters for tested connections. Thermodynamic justification for the use of more complex configuration was verified. The exhaust steam pressure calculation was presented. Three methods of computing the heat transfer coefficient based on characteristic numbers, namely the Heat Exchange Institute (HEI) method, and the American Society of Mechanical Engineers (ASME) standard, were used. Calculation results were validated with the real data. The most accurate model was indicated and used in heat balance calculations. The assumptions and simplifications for the calculations are discussed. Examples of the calculation results are presented.