Search results

Filters

  • Journals
  • Authors
  • Keywords
  • Date
  • Type

Search results

Number of results: 3
items per page: 25 50 75
Sort by:
Download PDF Download RIS Download Bibtex

Abstract

The aim of this paper is to analyse whether the medical rehabilitation segment is an important part of the entire Polish healthcare system, and if the medical rehabilitation services are provided with adequate levels of financing and management. The study reviews published literature and legal acts, and undertakes an analysis of data acquired from international and national health data repositories. In Poland there exists no coordination between medical, vocational and social rehabilitation or between the rehabilitation delivered by the health resort facilities. There is an observed lack of coordination among public fund payers. The described lack of coordination influences not only patient treatments (it is difficult to measure outputs and outcomes), but also makes summarizing the total expenditures on curative rehabilitation more difficult. Even though numerous countries spend a smaller or comparable amount of money on rehabilitation (per patient), funds allocated to rehabilitation in Poland (expressed in PPS) are over seven times lower than in France, about five times lower than in Austria and Belgium, and three times lower than in the Netherlands.

Go to article

Authors and Affiliations

Ewa Kosycarz
Download PDF Download RIS Download Bibtex

Abstract

The current survey was carried out to evaluate the effect of different nitrogen levels (0, 2.1, 3.0, 3.9 g ∙ pot–1 nitrogen as urea 46%) on tomato fruit worm Helicoverpa armigera on six common tomato cultivars (e.g., Kingston, Riogrand, Earlyurbana, Redston, Superstrain-B and Primoearly) under laboratory conditions [25 ± 1°C, 60 ± 5% RH, 16 : 8 (L : D) h]. The mortality, developmental period of immature stages as well as the longevity and fecundity of adult stages were recorded. Data were analyzed based on the age-stage, two-sex lifetable theory. The longest (24.21 ± 0.59 days) larval developmental period was recorded in Earlyurbana variety with zero nitrogen level and the shortest (15.44 ± 0.36 days) in Superstrain-B variety with the highest nitrogen level. Consequently, the net reproductive rate (R0) ranged from 35.7 ± 7.06 to 62.16 ± 18.9 offspring/female/individual in Redston variety with zero nitrogen level and in Superstrain-B variety with the highest nitrogen level, respectively. The lowest and highest values of the intrinsic rate (r) and finite rate of increase (l) were estimated for Redston variety with zero level of nitrogen (0.0712 ± 0.0065 and 1.0732 ± 0.0069 day–1) and Superstrain-B variety with the highest nitrogen fertilizer (0.1507 ± 0.0057 and 1.1629 ± 0.0066 day–1), respectively. The results demonstrated that nitrogen fertilizer influenced nearly all the life parameters of the pest which depended on the cultivars. Finally, it could be concluded that Kingston and Superstrain-B were suitable and Earlyurbana and Redston were unsuitable host plant cultivars for H. armigera.

Go to article

Authors and Affiliations

Fereshteh Salehi
Gholamhossein Gharekhani
Jalal Shirazi
Nahid Vaez
Download PDF Download RIS Download Bibtex

Abstract

A new design of decentralized Load Frequency Controller for interconnected thermal non-reheat power systems with AC-DC parallel tie-lines based on Genetic Algorithm (GA) tuned Integral and Proportional (IP) controller is proposed in this paper. A HVDC link is connected in parallel with an existing AC tie-line to stabilize the frequency oscillations of the AC tie-line system. Any optimum controller selected for load frequency control of interconnected power systems should not only stabilize the power system but also reduce the system frequency and tie line power oscillations and settling time of the output responses. In practice Load Frequency Control (LFC) systems use simple Proportional Integral (PI) or Integral (I) controller. The controller parameters are usually tuned based on classical or trial-and-error approaches. But they are incapable of obtaining good dynamic performance for various load change scenarios in multi-area power system. For this reason, in this paper GA tuned IP controller is used. A two area interconnected thermal non-reheat power system is considered to demonstrate the validity of the proposed controller. The simulation results show that the proposed controller provides better dynamic responses with minimal frequency and tie-line power deviations, quick settling time and guarantees closed-loop stability margin.

Go to article

Authors and Affiliations

S. Selvakumaran
V. Rajasekaran
R. Karthigaivel

This page uses 'cookies'. Learn more