Abstract

Verification of electrical safety in low-voltage power systems includes the measurement of earth fault loop impedance. This measurement is performed to verify the effectiveness of protection against indirect contact. The widespread classic methods and meters use a relatively high value of the measuring current (5÷20) A, so that they are a source of nuisance tripping of residual current devices (RCDs). The meters dedicated to circuits with RCDs usually use an extremely low value of current (lower than 15 mA), which in many cases it is not acceptable in terms of the measurement accuracy. This paper presents a method of earth fault loop impedance measurement in 3-phase circuits, without nuisance tripping of RCDs – the concept of measurement, the meter structure and the experimental validation. The nuisance tripping is avoided in spite of the use of measuring current value many times higher than that of the rated residual current of RCDs. The main advantage of the proposed method is the possibility of creating values of measuring current in a very wide range, what is very important with regard to accuracy of the measurement.

Go to article

Authors and Affiliations

Stanisław Czapp
Download PDF Download RIS Download Bibtex

Abstract

The study of liquid crystalline assemblies, with an emphasis on biological phenomena, is now accessible using newly developed microdevices integrated with X-ray analysis capability. Many biological systems can be described in terms of gradients, mixing, and confinement, all of which can be mimicked with the use of appropriate microfluidic designs. The use of hydrodynamic focusing creates well-defined mixing conditions that vary depending on parameters such as device geometry, and can be quantified with finite element modelling.We describe experiments in which geometry and strain rate induce finite changes in liquid crystalline orientation. We also demonstrate the online supramolecular assembly of lipoplexes. The measurement of lipoplex orientation as a function of flow velocity allows us to record a relaxation process of the lipoplexes, as evidenced by a remarkable 4-fold azimuthal symmetry. All of these processes are accessible due to the intentional integration of design elements in the microdevices.

Go to article

Authors and Affiliations

H.M. Evans
R. Dootz
S. Köster
B. Struth
T. Pfohl

This page uses 'cookies'. Learn more