Abstract

An alternative method for analysis of acoustic emission (AE) signals generated by partial discharges (PD), based on a correlation between voltage phase run and AE pulses, so called phase resolved PD pattern (PRPD), is presented in the paper. PRPD pattern is a well-known analysis tool commonly used in such PD diagnostic methods as conventional electrical and UHF ones. Moreover, it yields various signal analysis abilities and allows a direct correlation indication between measurement results achieved using different methods. An original PRPD measurement methodology applied for AE method as well as some exemplary measurement results and further data analysis capabilities are presented in the paper. Also a comparative analysis of PRPD patterns achieved using various measurement methods and different PD source configurations have been investigated. All presented experiments were done under laboratory conditions using PD model sources immersed in the insulation oil. The main purpose of the presented research is to indicate an all-embracing analytical tool that yields an ability to direct comparison (qualitative as well as quantitative) of the AE measurement results with other commonly applied PD measurement methods. The presented results give a solid fundamental for further research work concerning a direct correlation method for AE and other described in the paper diagnostic techniques, mainly in order to continue PD phenomena analysis and assessment in real life high voltage apparatus insulation systems under normal onsite operation conditions.
Go to article

Authors and Affiliations

Michał Kunicki
Andrzej Cichoń
Download PDF Download RIS Download Bibtex

Abstract

The subject presented in this paper refers to measurements and assessment of the corrected sound pressure level values (noise) occurring around a medium-power transformer. The paper presents the values of noise accompanying the operation of the power object before and after its modernization, which consisted in repeated core pressing and replacement of the cooling system. The main aim of the research work was the assessment of the influence of the repair work on the noise level emitted into the environment.

Go to article

Authors and Affiliations

Sebastian Borucki
Andrzej Cichoń
Tomasz Boczar
Download PDF Download RIS Download Bibtex

Abstract

On-load tap changers (OLTC) are some of the main transformer elements that make voltage adjustment in a power network possible. Their failures often cause shutdowns of distribution transformers. The paper presents research work aimed at the assessment of the technical condition of OLTCs by the acoustic emission method (EA). This method makes the OLTC diagnosis possible without the need of disconnecting the transformer from the system. The measurements were taken in laboratory conditions. The influence on the operation non-concurrence of the power tap changer contacts on the AE registered signals has been investigated. The signals registered were subjected to analyses in the time and time-frequency domains. The result analysis in the time domain was carried out using the Hilbert transform and calculating characteristic times for the particular runs. A short-time Fourier transform was used for the assessment of results in the time-frequency domain.

Go to article

Authors and Affiliations

Andrzej Cichoń
Sebastian Borucki
Tomasz Boczar
Download PDF Download RIS Download Bibtex

Abstract

An acoustic emission method (AE) is widespread and often applied for partial discharge (PD) diagnostics, mainly due to its ease of application as well as noninvasiveness and relatively high sensitivity. This paper presents comparative analysis of AE signals measurement results archived under laboratory conditions as well as on-site actual AE signals generated by inside PDs in electrical power transformer during its normal service. Three different PD model sources are applied for laboratory research: point to point, multipoint to plate and surface type. A typical measuring set up commonly used for on-site transformer PD diagnostics is provided for the laboratory tasks: piezoelectric joint transducer, preamplifier, amplifier and measuring PC interface. During the on-site research there are three measuring tracks applied simultaneously. Time domain, time-frequency domain and statistical tools are used for registered AE signals analysis. A number of descriptors are proposed as a result of the analysis. In the paper, at- tempt of AE signals descriptors, archived under laboratory condition application possibilities for on-site PD diagnostics of power transformers during normal service is made.
Go to article

Authors and Affiliations

Michał Kunicki
Andrzej Cichoń
Sebastian Borucki
Download PDF Download RIS Download Bibtex

Abstract

A verification study of ultrasound transmission numerical simulation results with experiment results is presented in this paper. The work considers a model of a transformer tank which is filled with electro insulating oil. In the experiment, performed under laboratory conditions, an ultrasound wave is generated by a piezoelectric transducer that is fixed in the centre of the tank and measured by another transducer mounted inside the tank at three distances: 10, 20 and 30 cm from the sound source. The transducer is able to measure and generate acoustic waves in the ultrasound frequency band up to 1 MHz. The simulation considers numerical calculation of acoustic pressure distribution inside the tank in which acoustic source emits waves with frequency equal to 100 kHz. Verification analysis has confirmed consistency of the numerically calculated values with the measurement results.

Go to article

Authors and Affiliations

Andrzej Cichoń
Daria Wotzka
Tomasz Boczar

Authors and Affiliations

Krzysztof Klimaszewski
Sebastian Borucki
Jacek Łuczak
Dariusz Zmarzły
Michał Kunicki
Andrzej Cichoń
Franciszek Witos
Czesław Leśnik
Dariusz Pleban
Milan Timko
Tomasz Rogala
Piotr Serafin
Tadeusz Gudra
Jerzy Filipiak
Dariusz Banasiak
Krzysztof Herman
Krzysztof Opieliński
Tomasz Hejczyk
Krzysztof Jasek
Mateusz Pasternak
Michał Grabka
Witold Kardyś
Andrzej Milewski
Adam Kawalec
Marta Okoń-Fąfara
Bartłomiej Fąfara
Aneta Olszewska
Piotr Pruchnicki
Marcin Wrzosek
Józef Nicpoń
Przemysław Podgórski
Tadeusz Pustelny
Marcin Szugajew
Olga Stec
Grzegorz Szerszeń
Daria Wotzka
Agnieszka Boruń
Adam Bald
Marzena Dzida
Sylwia Jężak
Monika Geppert-Rybczyńska
Katarzyna Kaczmarek
Tomasz Hornowski
Arkadiusz Józefczak
M. Kubovčíková
A. Skumiel
Z. Rozynek
M. Timko
Peter Kopcansky
Bogumił Linde
Vyacheslav N. Verveyko
Marina V. Verveyko
Darya V. Verveyko
Andrey Yu. Verisokin
Nikita S. Chebrov
Witold Mikulski
Danuta Augustyńska
Bożena Smagowska

This page uses 'cookies'. Learn more