The uncontrolled rectifier and controlled rectifier which use fixed switching frequency control strategy are applied usually during the working of a high-power high- speed permanent magnet generator (HSPMG). Even for the controlled rectifier, it will generate harmonics. The electromagnetic performance of the HSPMG is also affected by these harmonics. In this paper, the influences of the fixed switching frequency control strategy on a HSPMG were studied. Based on the Fourier theory, the harmonic currents of the generator were analyzed, and the change of harmonic distribution range and current total harmonic distortion (THD) were obtained. By using an indirect field-circuit coupling method, the influences of the fixed switching frequency control strategy on the losses and torque of the generator were analyzed. The relations between the switching frequency and the losses and torque of the generator were obtained, and the change mechanism of the loss was revealed. The obtained conclusions can provide reference for the optimized choice of the switching frequency of the distributed generation system with the HSPMG. It can also provide support for the HSPMG electromagnetic structural optimization and the optimization of the loss and harmonic on the system level.

Go to article

Authors and Affiliations

Qiu Hongbo
Wei Yanqi
Yang Cunxiang
Hu Kaiqiang

This page uses 'cookies'. Learn more