Abstract

One of the concepts of the ventilation rate control in buildings with dense and unpredictable occupancies is based on the CO2 measurements. There are many limitations regarding the validity of CO2 measurement inputs as suitable to the ventilation rate control. Verifying research has been conducted in an air-conditioned auditorium, in the real conditions at altered ventilation air thermal parameters and variable occupancy. The CO2 and the number concentrations of the fine and coarse aerosol particles(> 0.3 μm) and bioaerosol particles (bacteria and staphylococci) as well as the indoor air thermal parameters were measured in the individual sectors of the occupied area. The sensory assessments and instrumental determinations of the acceptability of indoor air quality (ACC) were also performed. The ventilation control strategy based, apart from the CO2 measurements, on the continuous monitoring of the perceived air quality (PAQ) in the auditorium sectors has been suggested. The PAQ monitoring could be accomplished by aerosol concentration measurements and the ACC instrumental determinations. This strategy should ensure a desired PAQ in sectors which benefit the occupants' comfort, health and productivity as well as energy savings not only in the case of its implementation in the considered auditorium.
Go to article

Authors and Affiliations

Bernard Połednik
Marzenna Dudzińska
Download PDF Download RIS Download Bibtex

Abstract

The indoor aerosols that arc. among others, generated by air-conditioning systems arc especially significant in school facilities. The measurements carried out in the new, air-conditioned auditorium have shown that the aerosol concentrations arc strongly dependent on the operation or the air-conditioning system and the presence of students. The aerosol concentration was approximately 5 times higher when the air-conditioning (AC) system was switched on. An increased air movement inside the auditorium and the connected with it rcsusperuion of the particles settled on the indoor surfaces could be responsible for this fact. It could also result from the ineffective operation ofthe AC filters. The presence of students in the auditorium caused an increase of the coarse aerosol particles irrespectively of the AC system operation. The results of aerosol particle monitoring should be taken into consideration while controlling the AC processes in order to ensure the desired indoor air quality in this type or facilities.
Go to article

Authors and Affiliations

Bernard Połednik
Marzenna Dudzińska
Mariusz Skwarczyński
Download PDF Download RIS Download Bibtex

Abstract

Levels and distribution of selected polybrorninated diphenyl ether congeners in dust samples taken from different indoor environments in Lublin, South-Eastern Poland, are reported. The most abundant congeners, found in the majority of sampling sites, were BOE 47, 100 and 28, respectively. The highest levels of examined congeners were observed in dust samples taken from a computer repair facility and labs. BOE 47, 99 and 100, occurring at highest levels and having the greatest contribution confirm that in Polish indoor environments polymer products contain Penta - BOE technical mixture.
Go to article

Authors and Affiliations

Amelia Staszowska
Bernard Połednik
Marzenna R. Dudzińska
Jacek Czerwiński