Search results

Filters

  • Journals
  • Authors
  • Keywords
  • Date
  • Type

Search results

Number of results: 3
items per page: 25 50 75
Sort by:
Download PDF Download RIS Download Bibtex

Abstract

The reduction of structural vibrations on the example of two pedestrian bridges (in Poznań and Wrocław) with using of tuned mass dampers (TMD) has been presented in the paper. The results of theoretical and experimental studies of pedestrian bridge vibrations has been described and discussed. Basing on the results of calculations and measurements, tuned mass dampers (TMD) has been designed and mounted in the structure of the bridges. The measurements after the assembly of TMD show a high efficiency of vibration damping.

Go to article

Authors and Affiliations

Wiesław Fiebig
Download PDF Download RIS Download Bibtex

Abstract

The paper shows the new method for noise reduction in external gear pumps based on the analysis of the pressure in inter teeth volumes. The simulation model and measurement results of pressure changes in the inter teeth volume has been presented. Based on simulation results an additional volume has been obtained, which is connected to the inter teeth volume (decompression filter volume). Due this additional volume the build down processes in the pump are longer and the pressure overdue in the inter teeth volumes are smaller. This leads to the reduction of the dynamical excitation forces inside the pump and noise, especially in the higher frequency rangeI.

Go to article

Authors and Affiliations

Wiesław Fiebig
Download PDF Download RIS Download Bibtex

Abstract

The paper presents results of the localization of main noise sources in the industrial plant. Identification of main noise sources was made with an acoustic camera using Beamforming Method. Parallel to the measurements by means of the acoustic camera, sound level measurements on the main noise sources have been performed. Based on the calculations, prediction regarding the noise emission at residential buildings located near to the plant has been determined. Acoustic noise maps have been performed with LEQ Professional software, which includes the 3D geometry of the buildings inside the plant. It has been established that, after introduction of noise reduction measures in the plant, the noise levels at the observation points in the residential area meets the limit values.

Go to article

Authors and Affiliations

Wiesław Fiebig
Damian Dąbrowski

This page uses 'cookies'. Learn more