[1] Khan,W., Hong, H. H., Satar, T., Ahmed, M., Khan, Z. A.,& Khan, M. Z. (2016). The KRISS primary vacuum gauge calibration standards:Areview. Journal of the Vacuum Society of Japan, 59(8), 222–235.
[2] Astrua, M., Mari, D., & Pasqualin, S. (2019). Improvement of INRiM static expansion system as vacuum primary standard between 10(-4) Pa and 1000 Pa. 19th International Congress of Metrology, 27007.
https://doi.org/10.1051/metrology/201927007 [3] Semwal, P., Khan, Z., Dhanani, K. R., Pathan, F. S., George, S., Raval, D. C., Thankey, P. L., Paravastu, Y., & Himabindu, M. (2012). Spinning rotor gauge based vacuum gauge calibration system at the Institute for Plasma Research. Journal of Physics: Conference Series, 390, 012027.
https://doi.org/10.1088/1742-6596/390/1/012027 [4] Bergoglio, M., & Calcatelli, A. (2004). Uncertainty evaluation of the IMGC-CNR static expansion system. Metrologia, 41, 278–284.
https://doi.org/10.1088/0026-1394/41/4/009 [5] Greenwood, J. C. (2006). Simulation of the operation and characteristics of static expansion pressure standards. Vacuum, 80, 548–553.
https://doi.org/10.1016/j.vacuum.2005.09.003 [6] Soriano Cardona, B., Torres Guzmán, J., & Santander Romero, L. (2001). Sistema de referencia nacional para la medición de vacío. Simposio de Metrología CENAM 2001, México.
[7] Bergoglio, M., Calcatelli, A., Marzola, L., & Rumiano, G. (1988). Primary pressure measurements down to 10(-6) Pa. Vacuum, 38(8–10), 887–891.
https://doi.org/10.1016/0042-207X(88)90486-1 [8] Fedchak, J. A., Abbott, P. J., & Hendricks, J. H. (2018). Review Article: Recommended practice for calibrating vacuum gauges of the ionization type. Journal of Vacuum Science & Technology A, 36, 030802.
https://doi.org/10.1116/1.5025060 [9] Torres Guzmán, J. C., Santander, L. A., & Jousten, K. (2005). Realization of the medium and high vacuum primary standard inCENAM,Mexico.Metrologia, 42(6), S157–S160.
https://doi.org/10.1088/0026-1394/42/6/S01 [10] Jousten, K., Röhl, P., & Aranda Contreras, V. (1999). Volume ratio determination in static expansion systems by means of a spinning rotor gauge. Vacuum, 52(4), 491–499.
https://doi.org/10.1016/S0042-207X(98)00337-6 [11] Herranz, D., Ruiz, S., & Medina, N. (2009). Volume ratio determination in static expansion systems by means of two pressure balances. XIX IMEKO World Congress, Fundamental and Applied Metrology, Portugal.
https://www.imeko2009.it.pt/Papers/FP_280.pdf [12] Phanakulwijit, S.,&Pitakarnnop, J. (2019). Establishment of Thailand’s national primary vacuum standard by a static expansion method. Journal of Physics: Conference Series, 1380, 012003.
https://doi.org/10.1088/1742-6596/1380/1/012003 [13] Jitschin, W. (2002). High-accuracy calibration in the vacuum range 0.3 Pa to 4000 Pa using the primary standard of static gas expansion. Metrologia, 39(3), 249–261.
https://doi.org/10.1088/0026-1394/39/3/2 [14] Kangi, R., Ongun, B., & Elkatmis, A. (2004). The new UME primary standard for pressure generation in the range from 9 × 10
-4 Pa to 103 Pa. Metrologia, 41(4), 251–256.
https://doi.org/10.1088/ 0026-1394/41/4/005 [15] International Organization for Standardization. (2011). Vacuum gauges – Calibration by direct comparison with a reference gauge ISO Standard No. 3567:2011.
https://www.iso.org/standard/59372.html [16] Antsukova, A. I., Gorobei, V. N., Liubomirov, A. B., Pimenova, A. A.,&Chernyshenko, A. A. (2019). Calibration of measuring instruments of low absolute pressures. IOP Conference Series: Journal of Physics: Conference Series, 1313, 012002.
https://doi.org/10.1088/1742-6596/1313/1/012002 [17] Ruiz González, S. (2011). Desarrollo de un nuevo patrón nacional de presión. Desde la columna de mercurio a patrones primarios de vacío [Doctoral dissertation, Universidad de Valladolid]. UVaDOC Repositorio Documental de la Universidad de Valladolid.
https://doi.org/10.35376/10324/830 [18] Joint Committee for Guides in Metrology. (2008). Evaluation of measurement data – Guide to the expression of uncertainty in measurement (JCGM 100:2008).
http://www.bipm.org/utils/common/ documents/jcgm/JCGM_100_2008_E.pdf [19] Joint Committee for Guides in Metrology. (2008). Evaluation of measurement data – Supplement 1 to the “Guide to the expression of uncertainty in measurement” – Propagation of distributions using a Monte Carlo method (JCGM 101:2008).
https://www.bipm.org/documents/20126/2071204/ JCGM_101_2008_E.pdf