Search results

Filters

  • Journals
  • Authors
  • Keywords
  • Date
  • Type

Search results

Number of results: 8
items per page: 25 50 75
Sort by:
Download PDF Download RIS Download Bibtex

Abstract

In this paper the MTPA, MTPF, constant torque and constant flux control trajectories are presented. These trajectories are calculated for a 6-phase asymmetric insettype SMPMSM generator with the assumption of a certain level of 3rd harmonic current injection. This injection technique increases the generator performance due to the cooperation of the fundamental and 3rd harmonic. The presented trajectories are used for fast control of the generator working in the gearless wind turbine system.
Go to article

Authors and Affiliations

Marek Gołębiowski
Download PDF Download RIS Download Bibtex

Abstract

The aim of this paper is presentation and comparison of calculation methods of the inductance matrix of a 3-column multi-winding autotransformer. Main and leakage autotransformer inductance was obtained using finite elements method. Static calculations were made at the current supply for 2D and 3D models, and mono-harmonic calculations were made at the voltage supply. In the mono-harmonic calculations the eddy current losses were taken into account, this made it possible to study relationship between the autotransformer parameters and the frequency. Calculations were made using Ansys and the authors' own programs in Matlab.

Go to article

Authors and Affiliations

Marek Gołębiowski
Damian Mazur
Download PDF Download RIS Download Bibtex

Abstract

The 15-winding and 3-column autotransformer supplying an 18-pulse rectifier circuit was developed. Presented methods can be used also for the autotransformers of other topologies supplying different kinds of converters. Presented methods make it possible to exactly calculate main and leakage inductances of the multi-winding autotransformer. The presented analysis of the eigenvalues and eigenvectors of the inductance matrix makes it possible to identify the influence nature of individual modes on the inductance matrix, and to compare the calculation results obtained using the presented methods. Frequency dependence of autotransformer parameters was shown. Also modes of the impedance matrix of the multi-winding autotransformer was investigated, this made it possible to identify the influence nature of individual modes on the inductance matrix. Using presented methods one can exactly calculate main and leakage inductances of the autotransformer. Thanks to this, one can design in optimal way autotransformers for supplying, for example, rectifier circuits, THD coefficients. The results of the measurements and simulations were also shortly presented at the end of the article.

Go to article

Authors and Affiliations

Marek Gołębiowski
Damian Mazur
Download PDF Download RIS Download Bibtex

Abstract

Commonly, the Park model is used to calculate transients or steady-state operations of synchronous machines. The expanded Park theory derives the Park equations from the phase-domain model of the synchronous machine by the use of transformations. Thereby, several hypothesis are made, which are under investigation in this article in respect to the main inductances of two different types of synchronous machines. It is shown, that the derivation of the Park equations from the phase-domain model does not lead to constant inductances, as it is usually assumed for these equations. Nevertheless the Park model is the most common analytic model of synchronous machines. Therefore, in the second part of this article a method using the evolution strategy is shown to obtain the parameters of the Park model.

Go to article

Authors and Affiliations

Christoph Schmuelling
Christian Kreischer
Marek Gołebiowski
Download PDF Download RIS Download Bibtex

Abstract

The paper discusses in detail the construction of the Core Less Axial Flux Permanent Magnet generator simulation model. The model has been prepared in such a way that full compatibility with the elements of the SimPowerSystem library of the Matlab/Simulink package is preserved, which allows easy use of the presented simulation model for testing the work of the generator as part of a larger system. The parameters used in the model come from the MES 3D calculations performed in the Ansys/Maxwell software, for a machine prototype with a rated power of 2.8 kW, which was then used to experimentally verify the correct operation of the presented model of machine.

Go to article

Authors and Affiliations

Marek Gołębiowski
Andrzej Smoleń
Lesław Gołębiowski
Damian Mazur
Download PDF Download RIS Download Bibtex

Abstract

In this paper a system of a grid side and a generator side converters, both working with a common capacitor, is presented. The 6-phase asymmetric inset-type SMPMSM generator is used. A large pole pair number of this generator enables a gearless wind turbine operation. The fundamental and 3rd harmonic cooperation is used to increase the generator performance. This is accomplished by means of the 3rd harmonic current injection. For that reason the generator side converter must have a neutral connection.

Go to article

Authors and Affiliations

Marek Gołębiowski
Lesław Gołębiowski
Damian Mazur
Matthias Humer
Download PDF Download RIS Download Bibtex

Abstract

The market value of essential oils is steadily increasing every year. They are mainly used as aromas and preservatives in food and cosmetics industries. The content and yield of the obtained extracts change across the seasons of the year. The knowledge of these differences is important for essential oils industry to gain the best quality and quantity of products. In this study Thuja occidentalis L. (Eng. northern white cedar) extract was obtained from leaves by maceration in dichloromethane. Plant material was collected during each season of the year and the finished products were thoroughly examined through GC-MS analysis. The seasonal variations of volatile compound composition showed that the most adequate period to obtain T. occidentalis extract on an industrial scale is spring. This is due to the best efficiency (almost 10%) and the highest content of monoterpenes (67%).
Go to article

Authors and Affiliations

Marek Chajduk
1
Marek Gołębiowski
1

  1. Laboratory of Analysis of Natural Compounds, Department of Environmental Analysis, Faculty of Chemistry, University of Gdańsk, ul. Wita Stwosza 63, 80-308 Gdańsk, Poland

This page uses 'cookies'. Learn more