Abstract

Reinforced concrete composite slab consists of a thin prefabricated slab in which span reinforcement is located and of concrete joined with the slab, with such concrete being laid on site.

The existence of a joint of two concretes in such floors is interpreted as introducing a contact layer into a monolithic slab. In the paper parameters of two models are estimated. The first is a model of a contact layer and the second is a model of a composite slab with a single degree of freedom. The models consider that the contact has elastic properties and inelastic properties causing energy dissipation. Experimental investigations are discussed further based on which the parameters values of the contact layer model were determined.

Delamination was experienced for the slabs characterised by low contact layer stiffness after applying a maximum load. In addition, the strains of a contact layer having low stiffness are accompanied by lower energy dissipation than of a layer with high stiffness.

The smaller stiffness of composite floors, as compared to monolithic floors, occurs as a consequence of the existence of a joint. Such decrease for a composite slab is interpreted in the model with a single degree of freedom as the serial connection of stiffness of a monolithic slab and an element considering the existence of a contact layer.

The stiffness of an element considering the existence of a contact layer decreases along with a load, and the elements corresponding to the higher stiffness of the contact layer are characterised by higher energy dissipation.

The aforementioned results of the investigations confirm the assumptions of the contact layer model and a composite slab model with a single degree of freedom. The findings made represent a basis for establishing a method of evaluating the condition of a joint in composite slabs according to statistical investigations.

Go to article

Authors and Affiliations

K. Gromysz
Download PDF Download RIS Download Bibtex

Abstract

A continuous contact layer exists between the top and bottom layer of concrete composite reinforced floors. The contact layer is characterised by linear elasticity and frictional properties. In this paper a model of single degree of freedom of composite floor is determined. The model assumes that the restoring forces and the non-conservative internal friction forces dissipating energy are produced within the contact layer. A hysteresis loop is created in the process of static loading and unloading of the model, with the energy absorption coefficient being defined on this basis. The value of the coefficient is rising along with the growing stiffness of the composite.

A critical damping ratio is a parameter describing free decaying vibration caused by non-conservative internal friction forces in the contact layer and in the bottom and top layer. The value of the ratio in the defined model is rising along with the lowering stiffness of the element representing contact layer.

The findings resulting from the theoretical analyses carried out, including the experimental tests, are the basis for the established methods of determining the concrete layer state for reinforced concrete floors. The method is based on energy dissipation in the contact layer.

Go to article

Authors and Affiliations

K. Gromysz