Search results

Filters

  • Journals
  • Authors
  • Keywords
  • Date
  • Type

Search results

Number of results: 20
items per page: 25 50 75
Sort by:
Download PDF Download RIS Download Bibtex

Abstract

In order to investigate the influence of vertical ground motion on seismic responses of story-isolation structures mounted on triple friction pendulum (TFP) bearings, the finite element model of a six-story building with various types of interlayer isolation TFP bearings under far field or near fault ground motions is established and analysed. A discrepancy rate function of peak interlayer shear, acceleration and displacement results is adopted to discuss the influence of the vertical seismic motions on isolation structural responses. Furthermore, the isolation form, the isolation period and the friction coefficient of bearings are changed to study their effect on the vertical seismic component’s influence. The results show that the influence of the vertical seismic component is considerable on the isolation layer especially under near-fault ground motions, so it should not be overlooked during the structural design; The change of isolation forms will greatly affect the influence of the vertical seismic component especially in the isolation layer and isolation systems with isolation devices set on higher stories or with less isolation layers will have less vertical seismic effect on story acceleration; The increase of the isolation period will globally result in the decrease of the influence of vertical seismic components, though in some cases it shows some sort of fluctuation before the final decrease; The increase of the friction coefficient will lead to the global decrease in the influence of the vertical seismic component in single-layer isolation structures, while it does not obviously affect those in the multi-layer isolation systems.
Go to article

Bibliography


[1] K. Ryan, C. Earl. “Analysis and Design of Inter-story Isolation Systems with Nonlinear Devices,” Journal of Earthquake Engineering 14(7): pp. 1044–1062, 2010. https://doi.org/10.1080/13632461003668020
[2] D.C.Charmpis, P.Komodromos, M.C.Phocas. “Optimized earthquake response of multi‐storey buildings with seismic isolation at various elevations,” Earthquake Engineering & Structural Dynamics 41(15): pp. 2289–2310, 2012. https://doi.org/10.1002/eqe.2187
[3] H. Fakhri, G.G. Amiri. “Nonlinear Response-History Analysis of Triple Friction Pendulum Bearings (TFPB), Installed Between Stories,” 15th World Conference on Earthquake Engineering, Lisbon, 2012.
[4] A. Reggio, M.D. Angelis. “Optimal energy‐based seismic design of non‐conventional Tuned Mass Damper (TMD) implemented via inter‐story isolation,” Earthquake Engineering & Structural Dynamics 44(10): pp. 1623–1642, 2015. https://doi.org/10.1002/eqe.2548
[5] M. Rabiei, F. Khoshnoudian. “Response of multistory friction pendulum base-isolated buildings including the vertical component of earthquakes,” Canadian Journal of Civil Engineering 38(10): pp. 1045–1059, 2011. https://doi.org/10.1139/l11-064
[6] K. Faramarz, R. Montazar. “Seismic Response of Double Concave Friction Pendulum Base-Isolated Structures Considering Vertical Component of Earthquake,” Advances in Structural Engineering 13(1): pp. 1–14, 2010. https://doi.org/10.1260/1369-4332.13.1.1
[7] V. Loghman, F. Khoshnoudian, M. Banazadeh. “Effect of vertical component of earthquake on seismic response of triple concave friction pendulum base-isolated structures,” Journal of Vibration & Control 21(11): pp. 2099–2113, 2013. https://doi.org/10.1177/1077546313503359
[8] D.M. Fenz, M.C. Constantinou. “Spherical sliding isolation bearings with adaptive behavior: Theory,” Earthquake Engineering and Structural Dynamics 37(2): pp. 163-183, 2008. https://doi.org/10.1002/eqe.751
[9] D.M. Fenz, M.C. Constantinou. “Spherical sliding isolation bearings with adaptive behavior: Experimental verification,” Earthquake Engineering & Structural Dynamics 37(2): pp. 185–205, 2010. https://doi.org/10.1002/eqe.750
[10] N.D. Dao. “Seismic Response of a Full-scale 5-story Steel Frame Building Isolated by Triple Pendulum Bearings under Three-Dimensional Excitations,” Dissertations & Theses - Gradworks, University of Nevada, 2012.
[11] T.C. Becker, S.A. Mahin. “Approximating peak responses in seismically isolated buildings using generalized modal analysis,” Earthquake Engineering & Structural Dynamics 42(12): pp. 1807–1825, 2014. https://doi.org/10.1002/eqe.2299
[12] J. Sheller, M.C. Constantinou. “Response history analysis of structures with seismic isolation and energy dissipation systems: verification examples for program SAP2000,” Report No. MCEER 99-02, Multidisciplinary Center for Earthquake Engineering Research, New York, 1999.
[13] W.I. Liao, C.H. Loh, S. Wan. “Earthquake responses of RC moment frames subjected to near-fault ground motions,” Structural Design of Tall & Special Buildings 10(3): pp. 219–229, 2001. https://doi.org/10.1002/tal.178
Go to article

Authors and Affiliations

Zhao Fang
1
Ping Yan
2

  1. Nanjing Institute of Technology, School of Architecture Engineering, Hongjing Avenue 1, 211167 Nanjing, China
  2. Jiangsu Provincial Architectural D&R Institute LTD, Chuangyi Road 86, 211167 Nanjing, China
Download PDF Download RIS Download Bibtex

Abstract

A lightning protection system (LPS) of an urban 110 kV substation is designed and analysed according to NFPA 780 and IEC 62305-3 standards. The analysis of the LPS is established on the value of risk assessment. The total area of the plant is described by one soil layer with uniform resistivity. This study aims to improve the understanding of an unexpected manner of the grounding system beneath lightning currents by clarifying the basic concepts of the lightning protection level and the new design procedure in this paper was clarified according to NFPA-780 level 1 for a lightning protection system. The program is integrated with the CDEGS software, which provides effective geometrical modeling with object and result visualization. Furthermore, module and automated fast Fourier transform (FFT) is implemented in this study to simulate electromagnetic fields in the time and frequency domains. These current values are compared to the desired protection levels within the standards. The study results show that for the improved protection of the system against lightning, the total power grid must be considered as a source of improvement for studying shielding influence and the protection levels provided inside this substation.

Go to article

Authors and Affiliations

Mohammed Ibrahim Taha
Lin Li
Ping Wang
Download PDF Download RIS Download Bibtex

Abstract

The numerical solutions of stress and strain components on the critical plane of tungsten carbide coating were solved based on the critical plane method in three-dimensional coordinate system, and accordingly three strain energy density parameters (Smith-Watson-Topper, Nita-Ogatta-Kuwabara and Chen parameters) were determined to reveal the fretting fatigue characteristics of tungsten carbide coating. In order to predict the fretting fatigue life based on the strain energy density criterion, the expressions between the strain energy density parameter and the fretting fatigue life was obtained experimentally. After the comparison of the three strain energy parameters, it was found that all three parameters could accurately predict the crack initiation position, but only the Smith-Watson-Topper parameters could accurately predict the crack initiation angle. The effects of cyclic load, normal load and friction coefficient on fretting fatigue damage behaviors were discussed by using the Smith-Watson-Topper criterion. The results show that the fretting fatigue life decreases with the increase of cyclic load; an increase in the normal contact load will cause the Smith-Watson-Topper damage parameters more concentrated at the outer edge of the bridge foot; a decrease in the friction coefficient will increase the Smith-Watson-Topper damage parameters in the middle of the contact surface.
Go to article

Authors and Affiliations

Xin Zeng
1 2
Xiaoxiao Wang
1 2
Xuecheng Ping
1 2
Renjie Wang
1 2
Tao Hu
3

  1. Tianjin University of Science and Technology, School of Mechanical Engineering, Tianjin 300222, China
  2. Tianjin University of Science and Technology, Tianjin Key Laboratory of Integrated Design and Online Monitoring of Light Industry and Food Engineering Machinery and Equipment, Tianjin 300222, China
  3. Shanghai Xifa Business Consult ing Co., Ltd., Shanghai 200232, China
Download PDF Download RIS Download Bibtex

Abstract

The rheological property of asphalt is an important factor affecting the pavement performance of asphalt binder, and the fundamental reason for the change of asphalt rheological property is the strong evolution of asphalt material meso structure. However, the internal mechanism of rejuvenated asphalt mastic system is complex and its rules are difficult to grasp. Aiming to study the relationship between meso mechanical parameters and rheological parameters of rejuvenated asphalt mastic, the meso structure model of rejuvenated asphalt mastic was established and improved based on the discrete element method. Moreover, the meso parameters of the model were obtained by the objective function method, and then the influences of various factorswere studied to construct the mathematical constitutive model of rheological parameter modulus and meso mechanical parameters. Combing with the reliability of the improved Burgers model was verified based on the rheological test results of rejuvenated asphalt mastic. In addition, the virtual test of dynamic shear rheological dynamic frequency scanning was carried out on the asphalt mastic sample by particle flow software. By adjusting the mesomechanical parameters, the simulation results (complex shear modulus and phase angle)were consistent with the test results. This study clarified the relationship between mesomechanics and macro performance, and this model could be used to obtain the complex shear modulus of rejuvenated asphalt mastic under different types, filler-asphalt ratio and external force environments by adjusting particle flow, wall boundary and other conditions, which can greatly save the workload for the later research and provide a theoretical basis for production experiments.
Go to article

Authors and Affiliations

Mei Lin
1
Yu Lei
1
Ping Li
1
Jun Shuai
1
Zhaoli Wang
2

  1. School of Civil Engineering, Lanzhou University of Technology, Lanzhou, 730050, China
  2. Gansu Road and Bridge Green Smart Construction Technology Industry Research Institute, Lanzhou, 730030, China
Download PDF Download RIS Download Bibtex

Abstract

The purpose of drumlin formation is to facilitate glacier flow. Drumlins form in a deforming layer between ice and ground, they produce a pimpled ground surface which causes less drag in the flowing system, after the fashion of the Prandtl effect which reduces boundary layer detachment (as in the flying golf ball). This pimpled surface has selforganising properties and this causes the development of a low drag situation. The drumlin field is the critical phenomenon; the formation of individual drumlins is a small part of the overall effect.
Go to article

Authors and Affiliations

Ian J. Smalley
Ping Lu
Ian F. Jefferson
Download PDF Download RIS Download Bibtex

Abstract

Radial basis function neural networks (RBF NNs) are one of the most useful tools in the classification of the sonar targets. Despite many abilities of RBF NNs, low accuracy in classification, entrapment in local minima, and slow convergence rate are disadvantages of these networks. In order to overcome these issues, the sine-cosine algorithm (SCA) has been used to train RBF NNs in this work. To evaluate the designed classifier, two benchmark underwater sonar classification problems were used. Also, an experimental underwater target classification was developed to practically evaluate the merits of the RBFbased classifier in dealing with high-dimensional real world problems. In order to have a comprehensive evaluation, the classifier is compared with the gradient descent (GD), gravitational search algorithm (GSA), genetic algorithm (GA), and Kalman filter (KF) algorithms in terms of entrapment in local minima, the accuracy of the classification, and the convergence rate. The results show that the proposed classifier provides a better performance than other compared classifiers as it classifies the sonar datasets 2.72% better than the best benchmark classifier, on average.

Go to article

Authors and Affiliations

Yixuan Wang
LiPing Yuan
Mohammad Khishe
Alaveh Moridi
Fallah Mohammadzade
Download PDF Download RIS Download Bibtex

Abstract

The grid integration of large-scale wind power will alter the dynamic characteristics of the original system and the power distribution among synchronous machines. Meanwhile, the interaction between wind turbines and synchronous machines will affect the damping oscillation characteristics of the system. The additional damping control of traditional synchronous generators provides an important means for wind turbines to enhance the damping characteristics of the system. To improve the low frequency oscillation characteristics of wind power grid-connected power systems, this paper adds a parallel virtual impedance link to the traditional damping controller and designs a DFIG-PSS-VI controller. In the designed controller, the turbine active power difference is chosen as the input signal based on residual analysis, and the output signal is fed back to the reactive power control loop to obtain the rotor voltage quadrature component. With DigSILENT/PowerFactory, the influence of the controller parameters is analyzed. In addition, based on different tie-line transmission powers, the impact of the controller on the low-frequency oscillation characteristics of the power system is examined through utilizing the characteristic root and time domain simulation analysis.
Go to article

Authors and Affiliations

Ping He
1
ORCID: ORCID
Yongliang Zhu
2
Qiuyan Li
3
Jiale Fan
1
Yukun Tao
1

  1. Zhengzhou University of Light Industry, College of Electrical and Information Engineering, China
  2. Zhengzhou University of Light Industry, College of Materials and Chemical Engineering, China
  3. State Grid Henan Electric Power Company, Economic and Technical Research Institute, China
Download PDF Download RIS Download Bibtex

Abstract

Diode neutral point clamped (NPC) three-level converters have been widely used in recent years. Aiming at the problems of the high device failure rate and unstable neutral point potential of NPC three-level converters, an NPC three-level circuit with fourth bridge arm redundancy is proposed based on the traditional NPC three-level converter. The redundant fourth bridge arm is used to realize the function of stabilizing voltage when there is no fault and replacing the fault half-bridge arm to maintain the continuous operation of the converter when there is a fault. By analyzing the working principle of space vector pulse width modulation (SVPWM) and the power loss of the switch, it is of particular significance to the design and control of NPC three-level converters in the future. Matlab/Simulink verifies the feasibility of the fault-tolerant circuit structure.
Go to article

Authors and Affiliations

Baoge Zhang
1
ORCID: ORCID
Shanyan Ping
1
Yi Long
1
Yuemin Jiao
1
Boxiang Wu
1

  1. School of Automation and Electrical Engineering, Lanzhou Jiaotong University, China
Download PDF Download RIS Download Bibtex

Abstract

Renewable energy sources are connected to the grid through inverters, resulting in reduced grid inertia and poor stability. Traditional grid-connected inverters do not have the function of voltage and frequency regulation and can no longer adapt to the new development. The virtual synchronous generator (VSG) has the function of voltage and frequency regulation and has more outstanding advantages than the traditional inverter. Based on the principle of the VSG, the relationship between energy storage capacity, frequency response and output power of the VSG is derived, and the relationship between the virtual inertia coefficient, damping coefficient and frequency characteristics of the VSG and output power is revealed. The mathematical model is established and modeled using the Matlab/Simulink simulation software, and the simulation results verify the relationship between energy storage capacity and frequency response and the output power of the VSG.
Go to article

Authors and Affiliations

Baoge Zhang
1
ORCID: ORCID
Shanyan Ping
1
Yi Long
1
Yuemin Jiao
1
Boxiang Wu
1

  1. School of Automation and Electrical Engineering, Lanzhou Jiaotong University, China
Download PDF Download RIS Download Bibtex

Abstract

Energy storage technology (EST) is an effectiveway to improve the power quality of renewable energy generation (such as solar energy and wind energy), but a single energy storage system (ESS) is difficult to meet the demand for the safe operation of the grid. According to the structure and operation characteristics of the existing battery/super-capacitor hybrid energy storage system (HESS), a battery/super-capacitor HESS is proposed. The working principle and three working modes (the super-capacitor pre-charging cold stand-by mode, the boost mode and buck mode) of the HESS are analyzed in detail. The state equations of the boost mode and buck mode are derived. The state space average method is used to establish the small signal equivalent model under the buck/boost mode. More-over, the charge and discharge control strategy of the HESS is obtained by combining the voltage closed-loop control. The simulation model is built in Matlab/Simulink to verify the effectiveness of the proposed HESS and its control strategy. The results show that the HESS and its control strategy can ensure the DC bus voltage has good stability and superior anti-interference, and it can simultaneously provide large current, increase the battery life, and improve the technical economy of energy storage.

Go to article

Authors and Affiliations

Zhen Zhang
Baoge Zhang
ORCID: ORCID
Donghao Wang
Ping Li
Yao Rong
Download PDF Download RIS Download Bibtex

Abstract

A source of pure silicon was added into an alloy refining system during a refining process with the application of a direct electric current. The effect of the temperature difference between the graphite electrodes and the alloy was decreased. The temperature increase value (ΔT) of the Al-28.51wt.%Si alloy sample caused by Joule heating was calculated by weighing the mass of primary silicon. When the current density was 5.0×105 A/m2, the overall temperature increase in the alloy was about 90°C regardless of the alloy composition. Adequate silicon atoms recorded the footprint of the electric current in the alloy melt. The flow convection generated by the electric current in the melt during the solidification process resulted in the refinement of primary silicon. The Fe impurity content in alloy refining without the electric current density was 2.16 ppm. However, it decreased to 1.27 ppmw with the application of an electric current density of 5.0×105 A/m2.
Go to article

Authors and Affiliations

Jiayan Li
1 2
Benson Kihono Njuguna
1 2
Ping Ni
1 2
Liang Wang
2 1
Yi Tan
1 2

  1. Dalian University of Technology, School of Materials Science and Engineering, No. 2 Linggong Road, Ganjingzi District, Dalian 116023, China
  2. Dalian University of Technology, Key Laboratory for Solar Energy Photovoltaic System of Liaoning Province, Dalian 116024, China
Download PDF Download RIS Download Bibtex

Abstract

Both corrosion and abrasion remove materials from some engineering components such as impact coal crusher hammers, pulverizer rings, chute liner, and rolls or molds. Intensive research has been done on improving the wear resistance of high chromium alloys, however, studies into corrosion resistance of high chromium alloys are insufficient. In order to determine the amount of ferroniobium addition in the wire to achieve the best corrosion resistance, and find out the mechanism of ferroniobium enhancing the corrosion resistance of the welding overlays, the high-Cr iron-based welding overlays with different niobium addition were fabricated by using self-made self-shielded metal-cored wires and their acidic corrosion resistance in 3.5 wt.% NaCl solution + 0.01 mol/L HCl solution were investigated by electrochemical corrosion test. The microstructure and corrosion morphology were characterized by OM, SEM, XRD and EDS. The polarization curves and values of I corr, E corr and Rc indicate the corrosion resistance is at the highest with 3.6 wt.% niobium addition, and at the lowest when the niobium addition is 10.8 wt.%. The corrosion of welding overlay occurs in the matrix of microstructure. With the increase of niobium addition from 3.6 wt.% to 10.8 wt.%, the proportion of network eutectic structure in the welding overlay is increased. Up to 10.8 wt.%, the microstructure is transformed from hypereutectic structure into eutectic one, leading to a higher acceleration of corrosion rate. When niobium addition reaches 14.4 wt.%, the welding overlay is transformed into a hypoeutectic structure. The addition of niobium element consumes carbon element in the alloy, which makes the increase of chromium content in the final solidified matrix, leading to an improvement in corrosion resistance.
Go to article

Authors and Affiliations

Dashuang Liu
1 2 3
Yucheng Wu
1
Weimin Long
2 4
Ping Wei
3
Rui Wang
3
ORCID: ORCID
Wei Zhou
1 5

  1. Hefei University of Technology, School of Material Science and Engineering, Hefei 230009, China
  2. Zhengzhou Research Institute of Mechanical Engineering Co., Ltd., Zhengzhou 450001, China
  3. Jiangsu University of Science and Technology, School of Material Science and Engineering, Zhenjiang 212003, China
  4. China Innovation Academy of Intelligent Equipment (Ningbo) Co., Ltd, Ningbo 315700, China
  5. School of Mechanical and Aerospace Engineering, Nanyang Technological University, 50 Nanyang Avenue, 639798, Singapore
Download PDF Download RIS Download Bibtex

Abstract

Based on the respective characteristics of line-commutated converter high-voltage direct current (LCC-HVDC) and voltage-source converter high voltage direct cur- rent (VSC-HVDC), two additional emergency DC power support (EDCPS) controllers are designed, respectively. In addition a coordinated control strategy based on a hybrid multi-infeed HVDC system for EDCPS is proposed. Considering the difference in system recovery between LCC-HVDC and VSC-HVDC in EDCPS, according to the magnitude of the amount of potential power loss, the LCC-HVDC and VSC-HVDC priority issues of boosting power for EDCPS are discussed in detail. Finally, a hybrid three-infeed HVDC that consists of two parallel LCC-HVDCs and one VSC-HVDC that is built in PSCAD/EMTDC are simulated. The effectiveness of the proposed approach is verified based on this hybrid three-infeed HVDC system.

Go to article

Authors and Affiliations

Congshan Li
ORCID: ORCID
Yikai Li
ORCID: ORCID
Jian Guo
Ping He
ORCID: ORCID
Download PDF Download RIS Download Bibtex

Abstract

High voltage direct current (HVDC) emergency control can significantly improve the transient stability of an AC/DC interconnected power grid, and is an important measure to reduce the amount of generator and load shedding when the system fails. For the AC/DC interconnected power grid, according to the location of failure, disturbances can be classified into two categories: 1) interconnected system tie-line faults, which will cause the power unbalance at both ends of the AC system, as a result of the generator rotor acceleration at the sending-end grid and the generator rotor deceleration at the receiving-end grid; 2) AC system internal faults, due to the isolation effect of the DC system, only the rotor of the generator in the disturbed area changes, which has little impact on the other end of the grid. In view of the above two different locations of disturbance, auxiliary power and frequency combination control as well as a switch strategy, are proposed in this paper. A four-machine two-area transmission system and a multi-machine AC/DC parallel transmission system were built on the PSCAD platform. The simulation results verify the effectiveness of the proposed control strategy.

Go to article

Authors and Affiliations

Congshan Li
ORCID: ORCID
Ping He
ORCID: ORCID
Youyi Wang
Yuyi Ji
Cunxiang Yang
Download PDF Download RIS Download Bibtex

Abstract

In response to the inability of the flexible DC transmission system connected to the AC grid under conventional control strategies to provide inertia to the system as well as to participate in frequency regulation, a virtual synchronous generator (VSG) control strategy is proposed for a voltage source converter (VSC)-based multi-terminal high-voltage direct current (VSC-MTDC) interconnection system. First, the virtual controller module is designed by coupling AC frequency and active power through virtual inertia control, so that the VSC-MTDC system can provide inertia response for AC grid frequency. Second, by introducing the power margin of the converter station into the droop coefficient, the unbalanced power on the DC side is reasonably allocated to reduce the overshoot of the DC voltage in the regulation process. Finally, the power regulation capability of the normal AC system is used to provide power support to the fault end system, reducing frequency deviations and enabling inter-regional resource complementation. The simulation model of the three-terminal flexible DC grid is built in PSCAD/EMTDC, and the effectiveness of the proposed control strategy is verified by comparing the conventional control strategy and the additional frequency control strategy.
Go to article

Authors and Affiliations

Congshan Li
1
ORCID: ORCID
Xiaowei Zhang
1
Ping He
1
ORCID: ORCID
Zikai Zhen
1
ORCID: ORCID
Kefeng Zhao
1

  1. College of Electrical Information Engineering, Zhengzhou University of Light Industry, China
Download PDF Download RIS Download Bibtex

Abstract

The grid integration of large-scale wind and solar energy affects the power flow of wind-PV-thermal-bundled power transmission systems and may introduce an unpredicted threat to the power system’s small signal stability. Meanwhile, a power system stabilizer (PSS) and static synchronous series compensator (SSSC) play an important role in improving the static and dynamic stability of the system. Based on this scenario and in view of the actual engineering requirements, the framework of wind-PV-thermal-bundled power transmitted by an AC/DC system with the PSS and SSSC is established considering the fluctuation of wind and photovoltaic power output and the characteristics of the PSS and SSSC. Afterwards, the situation model is constructed in the IEEE 2-area 4-unit system, and the influence of the PSS and SSSC on the system stability under different operating conditions is analyzed in detail through eigenvalue analysis and time-domain simulation. Finally, an index named the gain rate is defined to describe the improvement of the stability limitations of various wind-PV-thermal operating conditions with the PSS and SSSC. The results indicate (K) that the damping characteristics, dynamic stability and stability limitations for various wind-PV-thermal operating conditions of the wind-PV-thermal-bundled power transmission system can be significantly improved by the interaction of the PSS and SSSC.

Go to article

Authors and Affiliations

Ping He
ORCID: ORCID
Xinxin Wu
Congshan Li
ORCID: ORCID
Mingming Zheng
Zhao Li
ORCID: ORCID
Download PDF Download RIS Download Bibtex

Abstract

This paper proposes an electromechanical transient method to build a battery energy storage system-based virtual synchronous generator model, suitable for a large-scale grid. This model consists of virtual synchronous generator control, system limitation and the model interface. The equations of a second-order synchronous machine, the characteristics of charging/discharging power, state of charge, operating efficiency, dead band and inverter limits are also considered. By equipping the energy storage converter into an approximate synchronous voltage source with an excitation system and speed regulation system, the necessary inertia and damping characteristics are provided for the renewable energy power system with low inertia and weak damping. Based on the node current injection method by the power system analysis software package (PSASP), the control model is built to study the influence of different energy storage systems. A study on the impact of renewable energy unit fluctuation on frequency and the active power of the IEEE 4-machine 2-area system is selected for simulation verification. Through reasonable control and flexible allocation of energy storage plants, a stable and friendly frequency environment can be created for power systems with high-penetration renewable energy.
Go to article

Authors and Affiliations

Juntao Cui
1
Zhao Li
2
ORCID: ORCID
Ping He
2
ORCID: ORCID
Zhijie Gong
2
Jie Dong
2
ORCID: ORCID

  1. Lanzhou Resources and Environment Voc-Tech University, China
  2. Zhengzhou University of Light Industry, China
Download PDF Download RIS Download Bibtex

Abstract

The static series synchronous compensator (SSSC) has demonstrated its capability in providing voltage support and improving power system stability. The objective of this paper is to analyze the dynamic interaction stability mechanism of a hybrid renewable energy system connected with doubly-fed induction generators (DFIGs) and solid oxide fuel cell (SOFC) energy with the SSSC. For this purpose, a linearized mathematical model of this modified hybrid single-machine infinite-bus (SMIB) power system is developed to analyze the physical mechanism of the SSSC in suppressing oscillations and the influence on the dynamic stability characteristics of synchronization. Typical impacting factors such as the series compensation level, the SOFC penetration and tie-line power are considered in the SMIB and two-area systems. The impact of dynamic interactions on enhancing damping characteristics and improving transient performance of the studied systems is demonstrated using eigenvalue analysis and dynamic time-domain simulations, which validates the validity of the proposed physical mechanism simultaneously.
Go to article

Bibliography

[1] Yu S.L., Fernando T., Iu H.-H.-C., Dynamic behavior study and state estimator design for solid oxide fuel cells in hybrid power systems, IEEE Transaction on Power Systems, vol. 31, no. 6, pp. 5190–5199 (2016).
[2] He P., Arefifar S.A., Li C.S., Small signal stability analysis of doubly-fed induction generator-integrated power systems based on probabilistic eigenvalue sensitivity indices, IET Generation, Transmission and Distribution, vol. 13, no. 14, pp. 3127–3137 (2019).
[3] YangY., Zhao J., Liu H., A matrix-perturbation-theory-based optimal strategy for small-signal stability analysis of large-scale power grid, Protection and Control of Modern Power Systems, vol. 3, no. 3, pp. 353–363 (2015).
[4] Liu J., Su C.,Wang C., Influence of solid oxide fuel cell on power system transient stability, The Journal of Engineering, vol. 2019, no. 16, pp. 1081–1086 (2019).
[5] Magdy G., Shabib G., Elbaset A.A., Optimized coordinated control of LFC and SMES to enhance frequency stability of a real multi-source power system considering high renewable energy penetration, Protection and Control of Modern Power Systems, vol. 3, no. 3, pp. 407–421 (2018).
[6] Du W.J., Wang H.F., Cai H., Modelling a grid-connected SOFC power plant into power systems for small-signal stability analysis and control, International Transactions on Electrical Energy Systems, vol. 23, no. 3, pp. 330–341 (2012).
[7] He P., Wu X.X., Li C.S., Damping characteristics improvement and index evaluation of a windpv- thermal-bundled power transmission system by combining PSS and SSSC, Archives of Electrical Engineering, vol. 69, no. 3, pp. 705–721 (2020).
[8] Vikash A., Sanjeev K.M., Power flow analysis and control of distributed FACTS devices in power system, Archives of Electrical Engineering, vol. 67, no. 3, pp. 545–561 (2018).
[9] Bhushan R., Chatterjee K., Effects of parameter variation in DFIG-based grid connected system with a FACTS device for small-signal stability analysis, IET Generation, Transmission and Distribution, vol. 11, no. 11, pp. 2762–2777 (2017).
[10] Verveckken J., Silva F., Barros D., Direct power control of series converter of unified power-flow controller with three-level neutral point clamped converter, IEEE Transactions on Power Delivery, vol. 27, no. 4, pp. 1772–1782 (2012).
[11] Wang L., Vo Q.S., Power Flow Control and Stability Improvement of Connecting an Offshore Wind Farm to a One-Machine In?nite-Bus System Using a Static Synchronous Series Compensator, IEEE Transactions on Sustainable Energy, vol. 4, no. 2, pp. 358–369 (2013).
[12] Das D., Haque M.E., Gargoom A., Operation and control of grid integrated hybrid wind-fuel cell system with STATCOM, 22nd Australasian Universities Power Engineering Conference (AUPEC), Bali, pp. 1–6 (2012).
[13] Mahapatra S., Panda S., Swain S.C., A hybrid firefly algorithm and pattern search technique for SSSC based power oscillation damping controller design, Ain Shams Engineering Journal, vol. 5, no. 4, pp. 1177–1188 (2014).
[14] Al-Sarray M., McCann R.A., Control of an SSSC for oscillation damping of power systems with wind turbine generators, IEEE Power and Energy Society Innovation Smart Grid Technologies Conference (ISGN), Washington, USA, pp. 1–5 (2017).
[15] Darabian M., Jalilvand A., Improving power system stability in the presence of wind farms using STATCOMand predictive control strategy, IETRenewable Power Generation, vol. 12, no. 1, pp. 98–111 (2018).
[16] Movahedi A., Halvaei Niasar A., Gharehpetian G.B., LVRT improvement and transient stability enhancement of power systems based on renewable energy resources using the coordination of SSSC and PSSs controllers, IET Renewable Power Generation, vol. 13, no. 11, pp. 1849–1860 (2019).
[17] Truong D.N., Ngo V.T., Designed damping controller for SSSC to improve stability of a hybrid offshore wind farms considering time delay, International Journal of Electrical Power and Energy Systems, vol. 65, no. 2, pp. 425–431 (2015).
[18] PramodKumar,Namrata K., Voltage control and power oscillation damping of multi-area power system using static synchronous series compensator, Journal of Electrical and Electronics Engineering, vol. 1, no. 5, pp. 26–33 (2012).
[19] Sahu P.R., Hota P.K., Panda S., Power system stability enhancement by fractional order multi input SSSC based controller employing whale optimization algorithm, Journal of Electrical Systems and Information Technology, vol. 5, no. 2018, pp. 326–336 (2018).
[20] Yu Y.N., Electric Power System Dynamics, Academic Press Inc (1983).
[21] He P.,Wen F.S., Ledwich G., An investigation on interarea mode oscillations of interconnected power systems with integrated wind farms, International Journal of Electrical Power and Energy Systems, vol. 78, no. 2, pp. 148–157 (2016).
[22] Wang L., Wang K.H., Dynamic stability analysis of a DFIG-based offshore wind farm connected to a power grid through an HVDC link, IEEE Transactions on Power Systems, vol. 26, no. 3, pp. 1501–1510 (2011).
[23] Sedghisigarchi K., Feliachi A., Dynamic and transient analysis of power distribution systems with fuel cells-Part II: Fuel-cell dynamic model, IEEE Transactions on Energy Conversion, vol. 19, no. 2, pp. 429–434 (2016).
[24] Benabid R., Boudour M., Abido M.A., Development of a new power injection model with embedded multi-control functions for static synchronous series compensator, IET Generation, Transmission and Distribution, vol. 6, no. 7, pp. 680–692 (2012).
[25] Pradhan A.C., Lehn P.W., Frequency-domain analysis of the static synchronous series compensator, IEEE Transactions on Power Delivery, vol. 21, no. 1, pp. 440–449 (2006). [26] Kundur P., Power system stability and control, McGraw-Hill Press (1994).

Go to article

Authors and Affiliations

Ping He
1
ORCID: ORCID
Pan Qi
1
ORCID: ORCID
Yuqi Ji
1
ORCID: ORCID
Zhao Li
1
ORCID: ORCID

  1. Zhengzhou University of Light Industry, No.5 Dongfeng Road, Jinshui District, Zhengzhou, 450002, China
Download PDF Download RIS Download Bibtex

Abstract

A hybrid multi-infeed HVDC (HMIDC) system is composed of line-commutated converter-based high-voltage direct current (LCC-HVDC) and voltage-source converterbased high-voltage direct current (VSC-HVDC), whose receiving ends have electrical coupling. To solve the problem of low-frequency oscillation (LFO) caused by insufficient damping in the HMIDC system, according to the multi-objective mixed H2/H∞ output feedback control theory with regional pole assignment, an additional robust damping controller is designed in this paper, which not only has good robustness, but also has strong adaptability to the change of system operation mode. In the paper, the related oscillation modes and transfer function of the controlled plant are obtained, which are identified by the total least squares estimation of signal parameters via rotary invariance technology (TLS-ESPRIT). In addition, the control-sensitive point (CSP) for suppressing LFO based on the small disturbance test method is determined, which is suitable for determining the installation position of the controller. The results show that the control sensitivity factor of VSC-HVDC is greater than that of LCC-HVDC so that adding an additional damping controller to VSC-HVDC is better than LCC-HVDC in suppressing the LFO of HMIDC. Finally, a hybrid double infeed DC transmission system with three receiving terminals is built on PSCAD/EMTDC where the time-domain simulations are performed to verify the correctness of the CSP selection and the effectiveness of the controller.
Go to article

Authors and Affiliations

Congshan Li
1
ORCID: ORCID
Yan Liu
1
ORCID: ORCID
Yikai Li
1
ORCID: ORCID
Ping He
1
ORCID: ORCID
Yan Fang
1
ORCID: ORCID
Tingyu Sheng
1
ORCID: ORCID

  1. School of Electrical and Information Engineering, Zhengzhou University of Light Industry, China
Download PDF Download RIS Download Bibtex

Abstract

At present, the back-propagation (BP) network algorithm widely used in the short-term output prediction of photovoltaic power stations has the disadvantage of ignoring meteorological factors and weather conditions in the input. The existing traditional BP prediction model lacks a variety of numerical optimization algorithms, such that the prediction error is large. The back-propagation (BP) neural network is easy to fall into local optimization thus reducing the prediction accuracy in photovoltaic power prediction. In order to solve this problem, an improved grey wolf optimization (GWO) algorithm is proposed to optimize the photovoltaic power prediction model of the BP neural network. So, an improved grey wolf optimization algorithm optimized BP neural network for a photovoltaic (PV) power prediction model is proposed. Dynamic weight strategy, tent mapping and particle swarm optimization (PSO) are introduced in the standard grey wolf optimization (GWO) to construct the PSO–GWO model. The relative error of the PSO–GWO–BP model predicted data is less than that of the BP model predicted data. The average relative error of PSO–GWO–BP and GWO–BP models is smaller, the average relative error of PSO–GWO–BP model is the smallest, and the prediction stability of the PSO–GWO–BP model is the best. The model stability and prediction accuracy of PSO–GWO–BP are better than those of GWO–BP and BP.
Go to article

Authors and Affiliations

Ping He
1
ORCID: ORCID
Jie Dong
1
ORCID: ORCID
Xiaopeng Wu
1
ORCID: ORCID
Lei Yun
1
ORCID: ORCID
Hua Yang
1
ORCID: ORCID

  1. Zhengzhou University of Light Industry, College of Electrical and Information Engineering, China

This page uses 'cookies'. Learn more