Search results

Filters

  • Journals
  • Autorzy
  • Słowa kluczowe
  • Data
  • Typ

Search results

Number of results: 3
items per page: 25 50 75
Sort by:
Download PDF Download RIS Download Bibtex

Abstract

The paper presents the results of sentence and logatome speech intelligibility measured in rooms with induction loop for hearing aid users. Two rooms with different acoustic parameters were chosen. Twenty two subjects with mild, moderate and severe hearing impairment using hearing aids took part in the experiment. The intelligibility tests composed of sentences or logatomes were presented to the subjects at fixed measurement points of an enclosure. It was shown that a sentence test is more useful tool for speech intelligibility measurements in a room than logatome test. It was also shown that induction loop is very efficient system at improving speech intelligibility. Additionally, the questionnaire data showed that induction loop, apart from improving speech intelligibility, increased a subject’s general satisfaction with speech perception
Go to article

Authors and Affiliations

Jędrzej Kociński
Edward Ozimek
Download PDF Download RIS Download Bibtex

Abstract

The aim of this work was to measure subjective speech intelligibility in an enclosure with a long reverberation time and comparison of these results with objective parameters. Impulse Responses (IRs) were first determined with a dummy head in different measurement points of the enclosure. The following objective parameters were calculated with Dirac 4.1 software: Reverberation Time (RT), Early Decay Time (EDT), weighted Clarity (C50) and Speech Transmission Index (STI). For the chosen measurement points, a convolution of the IRs with the Polish Sentence Test (PST) and logatome tests was made. PST was presented at a background of a babble noise and speech reception threshold - SRT (i.e. SNR yielding 50% speech intelligibility) for those points were evaluated. A relationship of the sentence and logatome recognition vs. STI was determined. It was found that the final SRT data are well correlated with speech transmission index (STI), and can be expressed by a psychometric function. The difference between SRT determined in condition without reverberation and in reverberation conditions appeared to be a good measure of the effect of reverberation on speech intelligibility in a room. In addition, speech intelligibility, with and without use of the sound amplification system installed in the enclosure, was compared.
Go to article

Authors and Affiliations

Jędrzej Kociński
Edward Ozimek
Download PDF Download RIS Download Bibtex

Abstract

The performance of binaural processing may be disturbed in the presence of hearing loss, especially of sensorineural type. To assess the impact of hearing loss on speech perception in noise regarding binaural processing, series of speech recognition measurements in controlled laboratory conditions were carried out. The spatial conditions were simulated using dummy head recordings played back on headphones. The Intelligibility Level Difference (ILD) was determined by measuring the change in the speech reception thresholds (SRT) between two configurations of a masking signal source (N) and a speech source (S), namely the S0N90 condition (where numbers stand for angles in horizontal plane) and the co-located condition (S0N0). To disentangle the head shadow effect (better ear effect) from binaural processing in the brain, the difference between binaural and monaural S0N90 condition (so-called Binaural Intelligibility Level Difference, BILD) value was calculated.

Measurements were performed with a control group of normal-hearing listeners and a group of sensorineural hearing-impaired subjects. In all conditions performance of the hearing-impaired listeners was significantly lower than normal-hearing ones, resulting in higher SRT values (3 dB difference in the S0N0 configuration, 7.6 dB in S0N90 and 5 dB in monaural S0N90). The SRT improvement due to the spatial separation of target and masking signal (ILD) was also higher in the control group (8.1 dB) than in hearing-impaired listeners (3.5 dB). Moreover, a significant deterioration of the binaural processing described by BILD was found in people with sensorineural deficits. This parameter for normal-hearing listeners reached a value of 3 to 6 dB (4.6 dB on average) and decreased more than two times in the hearing-impaired group to 1.9 dB on average (with a deviation of 1.4 dB). These findings could not be explained by individual average hearing threshold (standard in audiological diagnostics) only. The outcomes indicate that there is a contribution of suprathershold deficits and it may be useful to consider binaural SRT measurements in noise in addition to the pure tone audiometry resulting in better diagnostics and hearing aid fitting.

Go to article

Authors and Affiliations

Anna Pastusiak
Dawid Niemiec
Jędrzej Kociński
Anna Warzybok

This page uses 'cookies'. Learn more