Abstract

The article presents the results of laboratory measurements of Ud breakdown voltages in a high-voltage vacuum insulating system for different pressures, contact gaps, type of electrode contacts and type of residual gas inside the discharge chamber. First of all, the electrical strength of the discharge chamber with a contact system terminated with contact pads made of W 70Cu 30 and Cu 75Cr 25 material was compared for selected values of contact gaps. It was found that below a pressure of p = 3.0 x 10 -1 Pa the electrical strength reaches an approximately constant value for each of the set contact gaps d. Analytical relationships were determined to calculate this value for each of the contact pads used. Above a pressure of p = 3.0 x 10 -1 Pa, the measured values of Ud breakdown voltages decrease sharply. The values of breakdown voltages in the discharge chamber with residual gases in the form of air, argon, neon and helium were also determined for selected values of contact gaps d. Depending on the residual gases used, significant differences were noted in the values of pressure p at which the loss of insulating properties in the discharge chamber occurred. These values were 3.3 x 10 -1 Pa for argon, 4.1 x 10 -1 Pa for air, 6.4 x 10 -1 Pa for neon, and 2.55 x 10 0 Pa for helium, respectively.
Go to article

Authors and Affiliations

Michał Lech
1
ORCID: ORCID
Paweł Węgierek
1
ORCID: ORCID

  1. Faculty of Electrical Engineering and Computer Science, Lublin University of Technology, Nadbystrzycka 38A str., 20-618 Lublin, Poland
Download PDF Download RIS Download Bibtex

Abstract

The article presents methodology for testing the electric strength of vacuum chambers designed for modern medium voltage switchgear developed by the authors, using two innovative test stands designed and constructed by the research team above. Verification of the correctness of operation of the test stands, as well as the validity of the developed methodology was carried out by performing a series of tests. It was determined that below certain pressure values in the tested chamber (from about 5.0×10 0 Pa for station 1 and for about 4.0×10 -1 Pa for station 2), the electric strength maintains a constant value, which guarantees stable operation of the vacuum chamber. The values of the total measurement uncertainty for the electric strength tests were also estimated.

Go to article

Authors and Affiliations

Paweł Węgierek
ORCID: ORCID
Michał Lech
ORCID: ORCID
Czesław Kozak
Justyna Pastuszak