Abstract

The neutral point clamped (NPC) three-level grid-tied converter is the key equipment connecting renewable energy and power grids. The current sensor fault caused by harsh environment may lead to the split of renewable energy. The existing sensor fault-tolerant methods will reduce the modulation ratio index of the converter system. To ensure continuous operation of the converter system and improve the modulation index, a model predictive control method based on reconstructed current is proposed in this paper. According to the relationship between fault phase current and a voltage vector, the original voltage vector is combined and classified. To maintain the stable operation of the converter and improve the utilization rate of DC voltage, two kinds of fault phase current are reconstructed with DC current, normal phase current and predicted current, respectively. Based on reconstructed three-phase current, a current predictive control model is designed, and a model predictive control method is proposed. The proposed method selects the optimal voltage vector with the cost function and reduces time delay with the current reconstruction sector. The simulation and experimental results showthat the proposed strategy can keep the NPC converter running stably with one AC sensor, and the modulation index is increased from 57.7% to 100%.
Go to article

Authors and Affiliations

Yanyan Li
1
ORCID: ORCID
Han Xiao
1
Nan Jin
1
ORCID: ORCID
Guanglu Yang
1 2

  1. College of Electrical and Information Engineering, Zhengzhou University of Light Industry, China
  2. Nanyang Cigarette Factory, China Tobacco Henan Industrial Co., Ltd., China
Download PDF Download RIS Download Bibtex

Abstract

The disadvantages of the conventional model predictive current control method for the grid-connected converter (GCC) with an inductance-capacitance-inductance (LCL) filter are a large amount of calculation and poor parameter robustness. Once parameters of the model are mismatched, the control accuracy of model predictive control (MPC) will be reduced, which will seriously affect the power quality of the GCC. The article intuitively analyzes the sensitivity of parameter mismatch on the current predictive control of the conventional LCL-filtered GCC. In order to solve these issues, a model-free predictive current control (MFPCC) method for the LCL-filtered GCC is proposed in this paper. The contribution of this work is that a novel current predictive robust controller for the LCL-filtered GCC is designed based on the principle of the ultra-local model of a single input single output system. The proposed control method does not require using any model parameters in the controller, which can effectively suppress the disturbances of the uncertain parameter variations. Compared with conventional MPC, the proposed MFPCC has smaller current total harmonic distortion (THD). When the filter parameters are mismatched, the control error of the proposed method is smaller. Finally, a comparative experimental study is carried out on the platform of Typhoon and PE-Expert4 to verify the superiority and effectiveness of the proposed MFPCC method for the LCL-filtered GCC.
Go to article

Authors and Affiliations

Leilei Guo
1
Mingzhe Zheng
1
ORCID: ORCID
Changzhou Yu
2
Haizhen Xu
2
Yanyan Li
1
ORCID: ORCID

  1. Zhengzhou University of Light Industry, College of Electrical and Information Engineering, China
  2. Hefei University, School of Advanced Manufacturing Engineering, China