Abstract

The main problem in the measurement of airborne sound insulation is the measurement of the sound power radiated by the barrier, in practice performed by measuring the sound pressure level and the acoustic absorption in the receiving room. Large variations of the sound pressure level in a reverberation room indicate the presence of dominating strong standing waves, so that it becomes necessary to install diffusing elements. In ISO 10140, the limits have been defined in which the reverberation time at frequencies at and above 100 Hz should be included. Sometimes, however, in the case of rooms with a large volume, obtaining the required parameters is difficult and sometimes even impossible. It should then be checked whether the measured sound insulation depends on the reverberation time.

The paper presents the results of sound insulation measurements at various reverberation time lengths in subsequent stages of diffusing elements installation in the receiving room. An analysis of diffusing materials amount and arrangement influence on the uniformity of the sound pressure level distribution and reverberation time in the room as well as the value of the measured sound insulation was carried out. Uncertainty of sound insulation measurement with partial uncertainties was adopted as a criterion supporting the assessment of the obtained results.

Go to article

Authors and Affiliations

Dominik Mleczko
Tadeusz Wszołek

Authors and Affiliations

Agnieszka Ozga
1
Jacek Wierzbicki
1
Dominik Mleczko
1

  1. Faculty of Mechanical Engineering and Robotics, Department of Mechanics and Vibroacoustics, AGH University of Krakow, Kraków, Poland
Download PDF Download RIS Download Bibtex

Abstract

New Year’s Eve is an example of a situation in which urban residents are exposed to an almost continuous and increased noise level from the impulsive sounds sources – fireworks. This custom has become a source of many controversies related to the protection of human and animal health or environmental pollution. However, current legal regulations only slightly affect the subject of noise of fireworks and its harmfulness. Currently, it does not seem possible to completely prohibit the use of fireworks in urban areas, but this does not mean that it is not possible to decrease the degree of their annoyance.

The paper consists the issues of identification, analysis and assessment of impulsive noise of fireworks and acoustic climate during New Year’s Eve. Material presented refers to measurements of time series, frequency spectrum and values of noise parameters of selected fireworks. It was presented, among others, that the measured values exceed the criteria for occupational noise (LCpeak), due to the direct hazard of hearing loss, from 1.8 dB at a distance of 25 m and 6.2 dB at a distance of 15 m. Also this work discusses results of impulsive noise measurements of fireworks recorded during New Year’s Eve in years 2016–2017. Material refers to measurements at three measurement points spread over the city of Kraków. Obtained results were compared with typical noise levels for night time in urban area, indicating also the main sources of annoyance and hazard from this type of noise.

Go to article

Authors and Affiliations

Bartłomiej Kukulski
Tadeusz Wszołek
Dominik Mleczko
Download PDF Download RIS Download Bibtex

Abstract

The specific working conditions of the wind turbine in strong wind cause a number of problems in the measurement of noise indicators used in its short and long-term assessment. The wind is a natural working environment of the turbine, but it also affects the measurement system, moreover, it can be a secondary source of other sounds that interfere with the measurement. One of the effective methods of eliminating the direct impact of wind on the measurement system is placing the microphone on the measurement board at ground level. However, the obtained result can not be directly compared with the admissible values, as it has to be converted to a result at a height of 4 m. The results of previous studies show that this relation depends, inter alia, on the speed and direction of the wind. The paper contains the results of measurements on the measurement board, according to EN 61400-11:2013, and at a height of 4 m above ground made simultaneously in three points around the 2 MW turbine at various instantaneous speeds and changing wind directions. Analysis of the impact of measuring point location on the measurement result of noise indicators and the occurrence of additional features affecting the relationship between the values measured on the board and at the height of 4 m, and especially the tonality, amplitude modulation and content of low frequency content, was m