Search results

Filters

  • Journals
  • Authors
  • Keywords
  • Date
  • Type

Search results

Number of results: 2
items per page: 25 50 75
Sort by:
Download PDF Download RIS Download Bibtex

Abstract

Optical Coherence Tomography (OCT) is one of the most rapidly advancing techniques. This method is capable of non-contact and non-destructive investigation of the inner structure of a broad range of materials. Compared with other methods which belong to the NDE/NDT group (Non-Destructive Evaluation/Non-Destructive Testing methods), OCT is capable of a broad range of scattering material structure visualization. Such a non-invasive and versatile method is very demanded by the industry. The authors applied the OCT method to examine the corrosion process in metal samples coated by polymer films. The main aim of the research was the evaluation of the anti-corrosion protective coatings using the OCT method. The tested samples were exposed to a harsh environment. The OCT measurements have been taken at different stages of the samples degradation. The research and tests results have been presented, as well as a brief discussion has been carried out.

Go to article

Authors and Affiliations

Paulina Antoniuk
Marcin Strąkowski
Jerzy Pluciński
Bogdan Kosmowski
Download PDF Download RIS Download Bibtex

Abstract

Distributed measurement often relies on sensor networks. In this paper, we present the construction of low-coherence fiber-optic Fabry–Pérot sensors connected into a quasi-distributed network. We discuss the mechanism of spectrum modulation in this type of sensor and the constraints of assembly of such sensors in the network. Particular attention was paid to separate the signals from individual sensors which can be achieved by cavity length-based addressing. We designed and built a laboratory model of a temperature sensors network. The employed sensors are low-coherence Fabry–Pérot interferometric sensors in a fiberoptics configuration. The extrinsic sensor cavity utilizes the thermal expansion of ceramics, and the sensors are addressed by the different lengths of the cavities. The obtained test results showthat the signal components from each sensor can be successfully separated, and the number of sensors could be expanded depending on the FWHM of the light source.
Go to article

Authors and Affiliations

Katarzyna Karpienko
1
Marcin J. Marzejon
1
Adam Mazikowski
1
Jerzy Plucinski
1

  1. Gdansk University of Technology, Faculty of Electronics, Telecommunications and Informatics, Department of Metrology and Optoelectronics, 11/12 Gabriela Narutowicza St., 80-233 Gdansk, Poland

This page uses 'cookies'. Learn more