Search results

Filters

  • Journals

Search results

Number of results: 4
items per page: 25 50 75
Sort by:
Download PDF Download RIS Download Bibtex

Abstract

Presented study aimed to determine metals distribution on the quartz fiber filters surface coated with particulate matter by using high and low-volume samplers. The distribution pattern was tested using two different sub-sampling schemes. Each sub-sample was mineralized in the nitric acid in a microwave oven. An analysis was performed by means of atomic absorption spectroscopy with electrothermal atomization GF-AAS technique, and the determined elements were: As, Cd, Pb and Ni. A validation of the analytical procedure was carried out using NIES 28 Urban Aerosols standard reference material.

It was assumed that metal is distributed uniformly if its normalized concentrations on a single sub-sample is within ±15% of the mean concentration over the whole filter. The normalized concentrations values exceed this range, indicating a non-homogenous metals distribution. There were no statistically significant differences in metals concentrations between particular sub-samples in the function of its position along the filters diameter.

Go to article

Authors and Affiliations

Kamila Widziewicz
Wioletta Rogula-Kozłowska
Krzysztof Loska
Download PDF Download RIS Download Bibtex

Abstract

Concentrations and elemental composition of fine (PM2.5) and coarse (PM2.5-10) ambient particles,

at two sampling points located at the same urban background sites, were investigated. The points were 20 m

distant from each other and at various heights (2 and 6 m) above the ground. A dichotomous sampler, equipped

with a virtual impactor, and a cascade impactor were used to sample the dust. An X-ray fluorescence spectrometer was used in the elemental analyses. The investigations revealed heterogeneity of the spatial distribution

and the elemental composition of suspended dust at the investigated urban background site. Coarse dust, whose

concentration at 2.0 m above the ground was affected by secondary emission from roads, soil and other local

low-level sources in some periods, appeared more heterogeneous.

Go to article

Authors and Affiliations

W. Rogula-Kozłowska
B. Błaszczak
K. Klejnowski
Download PDF Download RIS Download Bibtex

Abstract

Thirteen fractions of ambient dust were investigated in Zabrze, a typical urban area in the central part of Upper Silesia (Poland), during a heating season. Fifteen PAH and Cr, Mn, Co, Ni, As, Se, Cd, Pb contents of each fraction were determined. The dust was sampled with use of a cascade impactor and chemically analyzed with an energy dispersive X-ray fluorescence spectrometer (PANalytical Epsilon 5) and a gas chromatograph with a flame ionisation detector (Perkin Elmer Clarus 500). The concentrations of PM1 and the PM1-related PAH and elements were much higher than the ones of the coarse dust (PM2.5-10) and the substances contained in it. The concentrations of total PAH and carcinogenic PAH were very high (the concentrations of PM1-, PM2.5-, and PM10-related BaP were 16.08, 19.19, 19.32 ng m-3, respectively). The municipal emission, resulted mainly from hard coal combustion processes, appeared to be the main factor affecting the air quality in Zabrze in winter.

Go to article

Authors and Affiliations

Wioletta Rogula-Kozłowska
Barbara Kozielska
Krzysztof Klejnowski

This page uses 'cookies'. Learn more