Search results

Filters

  • Journals
  • Authors
  • Keywords
  • Date
  • Type

Search results

Number of results: 6
items per page: 25 50 75
Sort by:
Download PDF Download RIS Download Bibtex

Abstract

One of the concepts of the ventilation rate control in buildings with dense and unpredictable occupancies is based on the CO2 measurements. There are many limitations regarding the validity of CO2 measurement inputs as suitable to the ventilation rate control. Verifying research has been conducted in an air-conditioned auditorium, in the real conditions at altered ventilation air thermal parameters and variable occupancy. The CO2 and the number concentrations of the fine and coarse aerosol particles(> 0.3 μm) and bioaerosol particles (bacteria and staphylococci) as well as the indoor air thermal parameters were measured in the individual sectors of the occupied area. The sensory assessments and instrumental determinations of the acceptability of indoor air quality (ACC) were also performed. The ventilation control strategy based, apart from the CO2 measurements, on the continuous monitoring of the perceived air quality (PAQ) in the auditorium sectors has been suggested. The PAQ monitoring could be accomplished by aerosol concentration measurements and the ACC instrumental determinations. This strategy should ensure a desired PAQ in sectors which benefit the occupants' comfort, health and productivity as well as energy savings not only in the case of its implementation in the considered auditorium.
Go to article

Authors and Affiliations

Bernard Połednik
Marzenna Dudzińska
Download PDF Download RIS Download Bibtex

Abstract

Artificial small water reservoirs existing over peatbogs of Łęczyńsko-Włodawskie Lakeland have high ecological value. Planktonie rotifer communities of the reservoirs are characterized by high species diversity, presence of rare species as well as high abundance of periphytic and benthic-pcriphytic forms. Low nutrients concentrations of studied reservoirs confirmed low total rotifers density, presence of indicatory species and high ratio of algaevorous to detritivorous species. The analysis of domination structure of planktonie rotifers showed very low stability of their community and high vulnerability for changes of habitat conditions.
Go to article

Authors and Affiliations

Andrzej Demetraki-Paleolog
Monika Tarkowska-Kukuryk
Download PDF Download RIS Download Bibtex

Abstract

We determined the performance of different Circulation Type Classifications (CTCs) to stratify air pollutants concentrations in Polish cities in winter. Our analysis is based on 15 CTCs calculated by COST 733 as well as on 5 manual universally used manual weather type classifications. For this purpose we compared and tested the explained variation (EV) and within-type standard deviation (WSD) methods. Finally, EV method has been chosen for evaluating classifications for daily values of SO2, NO2, PM I O and CO as well as vertical dispersion conditions obtained from SODAR data. We also presented the methodology of choosing smog episode days based on 90-percentile values. For the winter smog episodes data from Krakow different classifications have been compared using Gini coefficient method. The best results for separate air pollution data series as well as for smog episode days were obtained for Hess-Brezowski Gro/3wetterlagen classification (HBGWL). Moreover, good results were obtained for the based on principal component analysis PCACA classification, Polish Niedzwiedz TCN2I, modified Polish Litynski LITTc, modified Lamb LWT2, and three modified HBGWL (GWTC26, OGWL, OGWLSLP) classifications. The same classifications except for HBGWL are good for SODAR data. For the best CTCs, the differences between various classes are visible, however a big scattering is still observed. Main urban air pollution problems arise in situations when flow with Southerly component is observed. Correlations between air pollution data and SODAR data (calculated for marginal means obtained for different classes) confirm a negative role of both low height of the ground-based inversion and long duration of the low-level elevated inversion in urban areas.
Go to article

Authors and Affiliations

Jolanta Godłowska
ORCID: ORCID
Anna Monika Tomaszewska
Download PDF Download RIS Download Bibtex

Abstract

The emission of dust from coal fired furnaces introduces a lot of contamination into the environment, including dangerous metal compounds, which occur as trace elements in hard and brown coal. After the coal is burnt, they are contained in the grains of respirable dust, which creates health hazard. The results of investigations into the distribution of several trace elements in granular composition of ash emitted from CFB boilers used in coal-fired heat and power station are presented. The research material was taken by means of a cascade impactor, enabling a different granulometrie fraction to be separated from a stream of dust that penetrated the electrofilter. The CP-AES method (inductively coupled plasma atomic emission spectroscopy) was used to determine trace elements after prior mineralization of samples by microwave method. The Authors presented the results of measurements and analyses, determining the ranges of trace elements' occurrence in dust, characterizing the distribution in PM,, PM25 and PM10 granulometrie fractions and determining the emission factors.
Go to article

Authors and Affiliations

Jan Konieczyński
Katarzyna Stec

This page uses 'cookies'. Learn more