The issues connected with the complex design of various facilities, including up-to-date boiler equipment as well as the ways of organizing the space around them, are the reasons why there is often a lack of room for mounting a flowmeter in accordance with the recommendations of manufacturers. In most cases the problem is associated with ensuring sufficient lengths of straight pipe leading into and out of a flowmeter. When this condition cannot be fulfilled, the uncertainty of measurement increases above the value guaranteed by the manufacturer of the flowmeter. This sort of operation problem has encouraged the authors of this paper to undertake research aimed at the analysis of applicability of averaging Pitot tubes in the areas of flow disturbance.