The article presents the assessment of the levels of radiated electromagnetic interference by commercial UAVs in the context of their popular use for various military tasks. The test was conducted in the frequency range from 30 MHz to 6 GHz, in an electromagnetically anechoic chamber, in accordance with the procedures provided for this type of checks. Apart from the control frequencies (which of course exceed the standards), it can be said that most of the tested UAVs using brushless motors do not exceed the emission levels specified by the military standard MIL-STD-461G. This opens the way to the use of COTS UAV as a carrier of electronic systems for the tasks of recognizing sources of radio signals in the investigated band.
Przejdź do artykułu

Autorzy i Afiliacje

Rafał Przesmycki
1
ORCID: ORCID
Jarosław Michalak
1
ORCID: ORCID

  1. Military University of Technology, ul. Gen. Sylwestra Kaliskiego 2, 00-908 Warsaw, Poland