Wyniki wyszukiwania

Filtruj wyniki

  • Czasopisma
  • Date

Wyniki wyszukiwania

Wyników: 4
Wyników na stronie: 25 50 75
Sortuj wg:

Abstrakt

The purpose of this study is to investigate a structure’s response to blast loading when composite columns are used instead of conventional reinforced concrete (RC) cross sections and when a conventional structure is retrofitted with braces. The study includes conducting dynamic analyses on three different structures: a conventional reference RC structure, a modified structure utilizing composite columns, and a modified structure retrofitted with steel braces. The two modified structures were designed in order to investigate their performance when subjected to blast loading compared to the conventional design. During the dynamic analyses, the structures were exposed to simulated blast loads of multiple intensities using the finite-element modelling software, SeismoStruct. To evaluate their performance, the responses of the modified structures were analyzed and compared with the response of the conventional structure. It was concluded that both the structure with composite columns and the steel brace structure experienced less damage than the conventional model. The best performance was obtained through the steel brace structure.

Przejdź do artykułu

Autorzy i Afiliacje

Y.E. Ibrahim
M. Almustafa

Abstrakt

In this paper, a frame structure based on the locally resonant (LR) mechanism of phononic crystals (PCs) is designed on account of the wide application of frame structures in high-rise buildings, and the band structures, displacement fields of eigenmodes, and transmission power spectrums of corresponding finite structure are calculated by finite element (FE) method. Numerical results and further analysis demonstrate that a full band gap with low starting frequency can be opened by the frame structure formed by periodically combining soft and hard materials, and the starting frequency can be further lowered with the adjustment of corresponding geometric parameters, which provides a theoretical basis for the studies on vibration insulation and noise reduction of high-rise buildings.

Przejdź do artykułu

Autorzy i Afiliacje

Yukun Wang
Denghui Qian
Jinghong Wu
Feiyang He

Abstrakt

This paper models the downlink Fifth Generation (5G) network that supports a flexible frame structure and a shorter Round-Trip Time (RTT) for Hybrid Automatic Repeat Request (HARQ). Moreover, the design of the renowned Time Division Multiple Access (TDMA) packet scheduling algorithms is revised to allow these algorithms to support packet scheduling in the downlink 5G. Simulation results demonstrate that the Proportional Fair provides a comparable performance to the delay–aware Maximum-Largest Weighted Delay First for simultaneously providing the desired transmission reliability of the Guaranteed Bit Rate (GBR) and Non-Guaranteed Bit Rate (Non- GBR) healthcare contents whilst maximizing the downlink 5G performance.

Przejdź do artykułu

Autorzy i Afiliacje

Huda Adibah Mohd Ramli

Abstrakt

Numerical analysis of robustness assessment of steel planar framed structures under sudden external column removal is presented. The analysis is based on the previous experimental and numerical analyzes conducted in the Ph.D. project.Advanced and validated finite element models of steel structures with bolted end plate joints were used using Abaqus software. Six different cases of analysis using flush and extended bolted end-plate joints were performed. The actual results of the axial forces and rotations of the joints, failure models, and other important factors about structure behaviour are presented. The clear division of the results obtained depended on the type of joint used in the structure. In the cases of application of extended end-plate joints in frame analysis, the required level of robustness was reached in all cases and stopping of collapse development was obtained. In all cases of frame analysis with flush end-plate joints, an insufficient level of robustness on progressive collapse was obtained and partial failures of the structures were reached. Due to the location of the external column, the catenary actions to mitigate progressive collapse were very limited.
Przejdź do artykułu

Autorzy i Afiliacje

Aleksander Kozlowski
1
ORCID: ORCID
Damian Kukla
1
ORCID: ORCID

  1. Rzeszów University of Technology, Faculty of Civil and Environmental Engineering and Architecture, Poznanska 2, 35-084 Rzeszów

Ta strona wykorzystuje pliki 'cookies'. Więcej informacji