Abstract

Design of a delta/polygon-connected autotransformer based 36-pulse ac-dc converter is presented in this paper. The 36-pulse topology is obtained via two paralleled eighteen-pulse ac-dc converters each of them consisting of a nine-phase (nine-leg) diode bridge rectifier. For independent operation of paralleled diode-bridge rectifiers, two interphase transformers (IPT) is designed and implemented. A transformer is designed to supply the rectifier. The design procedure of magnetics is in a way such that makes it suitable for retrofit applications where a six-pulse diode bridge rectifier is being utilized. The proposed structure has been implemented and simulated using Matlab/Simulink software under different load conditions. Simulation results confirmed the significant improvement of the power quality indices (consistent with the IEEE-519 standard requirements) at the point of common coupling. Furthermore, near unity power factor is obtained for a wide range of DTCIMD operation. A comparison is made between 6-pulse and proposed converters from view point of power quality indices. Results show that input current total harmonic distortion (THD) is less than 4% for the proposed topology at variable loads.

Go to article

Authors and Affiliations

Rohollah Abdollahi
Download PDF Download RIS Download Bibtex

Abstract

The paper presents a three-phase grid-tied converter operated under unbalanced and distorted grid voltage conditions, using a multi-oscillatory current controller to provide high quality phase currents. The aim of this study is to introduce a systematic design of the current control loop. A distinctive feature of the proposed method is that the designer needs to define the required response and the disturbance characteristic, rather than usually unintuitive coefficients of controllers. Most common approach to tuning a state-feedback controller use linear-quadratic regulator (LQR) technique or pole-placement method. The tuning process for those methods usually comes down to guessing several parameters. For more complex systems including multi-oscillatory terms, control system tuning is unintuitive and cannot be effectively done by trial and error method. This paper proposes particle swarm optimization to find the optimal weights in a cost function for the LQR procedure. Complete settings for optimization procedure and numerical model are presented. Our goal here is to demonstrate an original design workflow. The proposed method has been verified in experimental study at a 10 kW laboratory setup.

Go to article

Authors and Affiliations

A. Gałecki
M. Michalczuk
A. Kaszewski
B. Ufnalski
L.M. Grzesiak
Download PDF Download RIS Download Bibtex

Abstract

This paper proposes a new dc-side active filter for wind generators that combines 12-pulse polygon auto-transformer rectifier with dc-side current injection method and dual-buck full-bridge inverter having not the “shoot-through” problem in conventional bridge-type inverters, and therefore this system with the character low harmonic distortion and high reliability. The proposed dc-side active filter is realized by using dual-buck full bridge converter, which directly injects compensation current at dc-side of two six-pulse diode bridges rectifiers. Compared with the conventional three-phase active power filter at ac-side, the system with the dc-side active filter draws nearly sinusoidal current by shaping the diode bridges output current to be triangular without using the instantaneous reactive power compensation technology, only using simple hysteretic current control, even though under load variation and unbalanced voltage disturbances, and while an acceptable linear approximation to the accurate waveform of injection current is recommended. The perfor- mance of the system was simulated using MATLAB/Simulink, and the possibility of the dc-side active filter eliminating current harmonics was confirmed in steady and transient states. The simulation results indicate, the system has a total harmonic distortion of current reduced closely to 1%, and a high power factor on the wind generator side.
Go to article

Authors and Affiliations

Xiao-Qiang Chen
Shou-Wang Zhao
Ying Wang