Abstract

Small-signal transmittances of the power stage of a flyback converter in continuous conduction mode are derived on the averaged model obtained by the separation of variables approach. The precise knowledge of these transmittances is necessary in the design process of the converter control circuit. Apart from mathematical formulas for transmittances, the numerical calculations of the frequency dependencies of the transmittances for the assumed set of the converter parameters are presented with the parasitic resistances of components taken into account. The results of the calculations are compared with the measurements performed on the laboratory model of the converter and a good consistency is observed. It is concluded, that the results of the paper may be useful in the designing process of a control circuit of the flyback converter.
Go to article

Authors and Affiliations

Maciej Bączek
1
ORCID: ORCID
Włodzimierz Janke
1
ORCID: ORCID
Jarosław Kraśniewski
1
ORCID: ORCID

  1. Department of Electronics and Computer Science, Koszalin University of Technology 2 Sniadeckich Street, 75-453 Koszalin, Poland
Download PDF Download RIS Download Bibtex

Abstract

Large-signal input characteristics of three DC–DC converter types: buck, boost and flyback working in the continuous conduction mode (CCM), obtained by simulations and measurements are investigated. The results of investigations are presented in the form of the analytical formulas and the exemplary results of the measurements and two forms of simulations: based on the full description of the converter components and on the averaged models. The parasitic resistances of the converter components are included in the simulations and their influence on the simulation results is discussed.

Go to article

Authors and Affiliations

Włodzimierz Janke
ORCID: ORCID
Maciej Bączek
ORCID: ORCID
Jarosław Kraśniewski
ORCID: ORCID
Marcin Walczak
Download PDF Download RIS Download Bibtex

Abstract

Small-signal transmittances: input-to-output and control-to-output of BUCK converter power stage working in CCM or DCM mode are discussed. Ideal converter case and converter with parasitic resistances are considered separately. Derivations of small-signal transmittances, based on different approaches to finding the converter averaged models, are presented and the results are compared. Apart from theoretical considerations, some results of numerical calculations are presented.