The paper describes the dynamics of a composite cantilever beam with an active element. The vibrations of the kinematically excited beam are controlled with the use of a Macro Fiber Composite actuator. A proportional control algorithm is considered. During the analysis, actuator is powered by a time-varying voltage signal that is changed proportionally to the beam deflection. The MFC element control system with the implemented algorithm allowed for changing the stiffness of the tested structure. This is confirmed by the numerical and experimental results. Resonance curves for the beam with and without control are determined. The results show a very good agreement in qualitative terms.
This study focuses to develop a new hybrid Engineered Cementitious Composite (ECC) and assesses the performance of a new hybrid ECC based on the steel short random fiber reinforcement. This hybrid ECC aims to improve the tensile strength of cementitious material and enhance better flexural performance in an RC beam. In this study, four different mixes have been investigated. ECC with Poly Vinyl Alcohol (PVA) fiber and PolyPropylene (PP) fiber of 2.0% volume fraction are the two Mono fiber mixes; ECC mix with PVA fiber of 0.65% volume fraction hybridized with steel fiber of 1.35% volume fraction, PP fiber of 0.65% volume fraction hybridized with steel of 1.35% volume fraction are the two additional different hybrid mixes. The material properties of mono fiber ECC with 2.0 % of PVA is kept as the reference mix in this study. The hybridization with fibers has a notable achievement on the uniaxial tensile strength, compressive strength, Young’s modulus, and flexural behavior in ECC layered RC beams. From the results, it has been observed that the mix with PVA fiber of 0.65% volume fraction hybrid with steel fiber of 1.35% volume fraction exhibitimprovements in tensile strength, flexural strength, andenergy absorption. ThePP fiber of 0.65% volume fraction hybridized with steel of 1.35% volume fraction mix has reasonable flexural performance and notable achievement in displacement ductility overthe reference mix.
The aim of the paper was to assess the bending strength of steel plate - concrete composite members, based on an experimental study performed by the authors together with theoretical and numerical analyses. The values of the mechanical parameters of the materials the beams were made from were adopted on the basis of the tests results. The proposed solutions have been verified by experiment. For this purpose the results of tests performed by the authors and other researchers have been used. The former ones are original, and the way of their presentation makes them applicable by other researchers. Following the results it can be stated that with respect to bending strengths from the experimental study the results obtained from the theoretical analysis are underestimated 6,6 % on average. The results based on the numerical analysis, on the other hand, are overestimated by - 7,5 % on average. The results of the theoretical and numerical analyses indicate that the interface slip between the steel plate and concrete part affect the bending strength of steel plate-concrete composite beams only slightly (about 2% on average).
In this study, free and forced vibration responses of carbon nanotube reinforced uniform and tapered composite beams are investigated. The governing differential equations of motion of a carbon nanotube (CNT) reinforced uniform and tapered composite beams are presented in finite element formulation. The validity of the developed formulation is demonstrated by comparing the natural frequencies evaluated using present FEM with those of available in literature. Various parametric studies are also performed to investigate the effect of aspect ratio, percentage of CNT content, ply orientation, and boundary conditions on natural frequencies and mode shapes of a CNT reinforced composite beam. It was observed that the addition of carbon nanotube in fiber reinforced polymer composite (FRP) beam enhances the stiffness of the structure which consequently increases the natural frequencies and alters the mode shapes.
This paper describes a fiber-based model proposed for computing the nonlinear longitudinal shear distribution in composite steel-concrete beams. The presented method incorporates the accurate stress-strain relationship with strain softening for concrete and bi-linear constitutive relation for structural steel, both in agreement with Eurocodes, however any one-dimensional constitutive relation can be used. The numerical solution for a simply supported beams loaded with the uniform load, concentrated force and both was presented. The results indicate that the highest value of the shear flow for a beam under an uniform load is at the ends and in the one third of the span length and for the point load, the maximum shear is in the proximity of the concentrated force.
The main objective of this study is to highlight the performance of beams composed of lightweight concretefilled steel tubes (square and circle sections) composite with reinforced concrete deck slab. A total of nine composite beams were tested included two circular and seven square concrete-filled steel tubes. Among the nine composite beams, one beam, S20-0-2000, was prepared without a deck slab to act as a reference specimen. The chief parameters investigated were the length of the specimen, the compressive strength of the concrete slab, and the effect of the steel tube section type. All beams were tested using the three-point bending test with a concentrated central point load and simple supports. The test results showed that the first crack in the concrete deck slab was recorded at load levels ranging from 50.9% to 77.2% of the ultimate load for composite beams with square steel tubes. The ultimate load increased with increasing the compressive strength of the concrete slab. Shorter specimens were more stiffness than the other specimens but were less ductile. The slip values were equal to zero until the loads reached their final stages, while the specimen S20-55-1100 (short specimen) exhibited zero slip at all stages of the load. The ultimate load of the hollow steel tube composite beam was 13.2% lower than that of the reference beam. Moreover, the ductility and stiffness of the beam were also higher for beams with composite-filled steel tubes.