[1] Veriche R.K.V., Zamorano M., Carpio M.: Effects of climate change on variations in climatic zones and heating energy consumption of residential buildings in the southern Chile. Energy Build. 215(2020), 109874.
[2] Gulan M., Salaj M., Rohal’-Ilkiv B.: Application of adaptive multivariable Generalized Predictive Control to a HVAC system in real time. Arch. Control Sci. 24(2014), 1, 67–84.
[3] Ilbeigi M., Ghomeishi M., Dehghanbanadaki A.: Prediction and optimization of energy consumption in an office building using artificial neural network and a genetic algorithm. Sustain. Cities Soc. 61(2020), 102325.
[4] Awbi H.B.: Air movement in naturally-ventilated buildings. Renew. Energ. 8(1996), 1–4, 241–247.
[5] Stavrakakis G.M., Koukou M.K., Vrachopoulos M.Gr., Markatos N.C.: Natural cross-ventilation in buildings: Building-scale experiments, numerical simulation and thermal comfort evaluation. Energ. Build. 40(2008), 9, 1666–1681.
[6] Bangalee M.Z.I., Lin S.Y., Miau J.J.: Wind-driven natural ventilation through multiple windows of a building: A computational approach. Energ. Build. 45(2012), 317–325.
[7] Dascalaki E., Santamouris M., Asimakopoulos D.N.: On the use of deterministic and intelligent techniques to predict the air velocity distribution on external openings in single-sided natural ventilation configurations. Sol. Energy. 66(1999), 3, 223–243.
[8] Liu X., Lv X., Peng Z., Shi C.: Experimental study of airflow and pollutant dispersion in cross-ventilated multi-room buildings: Effects of source location and ventilation path. Sustain. Cities Soc. (2020), 52, 101822.
[9] Hu Y., Heiselberg P.K., Guo R.: Ventilation cooling/heating performance of a PCM enhanced ventilated window-an experimental study. Energ. Build. 214(2020), 109903.
[10] Chen Y., Tong Z., Wu W., Samuelson H., Malkawi A., Norford L.: Achieving natural ventilation potential in practice: Control schemes and levels of automation. Appl. Energ. 235(2019), 1, 1141–1152.
[11] Chen J., Brager G.S., Augenbroe G., Song X.: Impact of outdoor air quality on the natural ventilation usage of commercial buildings in the US. Appl. Energ. 235(2019), 1, 673–684.
[12] Goudarzi N., Sheikhshahrokhdehkordi M., Khalesi J., Hosseiniirani S.: Airflow and thermal comfort evaluation of a room with different outlet opening sizes and elevations ventilated by a two-sided wind catcher. J. Build. Eng. 37(2021), 102112.
[13] Park D.Y., Chang S.: Effects of combined central air conditioning diffusers and window-integrated ventilation system on indoor air quality and thermal comfort in an office. Sustain. Cities Soc. 61(2020), 102292.
[14] Tao Y., Zhang H., Zhang L., Zhang G., Tu J., Shi L.: Ventilation performance of a naturally ventilated double-skin façade in buildings. Renew. Energ. 167(2020), 184–198.
[15] Tartarini F., Schiavon S., Cheung T., Hoyt T.: CBE thermal comfort tool: online tool for thermal comfort calculations and visualizations. SoftwareX 12(2020), 100563.
[16] Liu S., Luo Z., Zhang K., Hang J.: Natural ventilation of a small-scale road tunnel by wind catchers: A CFD simulation study. Atmosphere 9(2018), 10, 411.
[17] Aghakhani M., Eslami G.: Thermal comfort assessment of underfloor vs. overhead air distribution system. J. Appl. Sci. 12(2012), 5, 473–479.
[18] Michaux G., Greffet R., Salagnac P., Ridoret J.: Modelling of an airflow window and numerical investigation of its thermal performances by comparison to conventional double and triple-glazed windows. Appl. Energ. 242(2019), 27–45.
[19] Phaff J.C., de Gids W.F., Ton J.A.,. van der Ree D.V., Schijndel L.L.M.: The ventilation of buildings: Investigation of the consequences of opening one window on the internal climate of a room. Report C 448, TNO Inst. for Environmental Hygiene and Health Technology (IMG-TNO), Delft 1980.
[20] Hashemi, M.M., Nikfarjam A., Raji H.: Novel fabrication of extremely high aspect ratio and straight nanogap and array nanogap electrodes. Microsyst. Technol. 25(2019), 541–549.
[21] Zhang Y., Olofsson T., Nair G., Zhao C., Yang B., Li A.: Cold windows induced airflow effects on the thermal environment for a large single-zone building. E3S Web Conf., 172(2020), 06003.
[22] Murmu R., Kumar P., Singh H.N.: Heat transfer and friction factor correlation for inclined spherical ball roughened solar air heater. Arch. Thermodyn. 41(2020), 2, 3–34.
[23] Roberto R.: Experimental and Numerical Analysis of Heat Transfer and Airflow on an Interactive Building Façade. Univ. Cagliari, Cagliari 2008.
[24] ANSYS Fluent UDF Manual,
http://www.ansys.com [25] Gosselin J., Chen Q.: A computational method for calculating heat transfer and airflow through a dual-airflow window. Energ. Build. 40(2008), 4, 452–458.
[26] Sun H., Zhao L. Zhang Y.: Evaluation of RNG and LES non-isothermal models for indoor airflow using PIV measurement data. T. ASABE 50(2007), 2, 621–631.
[27] Li X., Yan Y., Tu J.: Evaluation of models and methods to simulate thermal radiation in indoor spaces. Build. Environ. 144 (2018), 15, 259–267.
[28] Olesen, B.W. and Brager, G.S.: A better way to predict comfort: The new ASHRAE standard, 55(2004), 204–207.
[29] Patankar S.: Numerical Heat Transfer and Fluid Flow. CRC, Boca Raton 1998.
[30] Sultanov M.M., Arakelyan E.K., Boldyrev I.A., Lunenko V.S., Menshikov P.D.: Digital twin’s application in control systems for distributed generation of heat and electric energy. Arch. Thermodyn. 42(2021), 2, 89–101.
[31] Asif M.A.: A Theoretical Study of the Size Effect of Carbon Nanotubes on the Removal of Water Chemical Contaminants. J. Res. Sci., Eng. Technol. 6(2018), 4, 21–27.
[32] Fuliotto R., Cambuli F., Mandas N., Bacchin N., Manara G., Chen Q.: Experimental and numerical analysis of heat transfer and airflow on an interactive building facade. Energ. Build. 42(2010), 1, 23–28.
[33] Little W.J.: Mollier Diagram for Air. AEDC Arnold Engineering and Development Center, Arnold Afb Tn, 1963.