Search results

Filters

  • Journals
  • Authors
  • Keywords
  • Date
  • Type

Search results

Number of results: 6
items per page: 25 50 75
Sort by:
Download PDF Download RIS Download Bibtex

Abstract

The TerraSAR-X add-on for Digital Elevation Measurement ( TanDEM-X) mission launched in 2010 is another programme – after the Shuttle Radar Topography Mission (SRTM) in 2000 – that uses space-borne radar interferometry to build a global digital surface model. This article presents the accuracy assessment of the TanDEM-X intermediate Digital Elevation Model (IDEM) provided by the German Aerospace Center (DLR) under the project “Accuracy assessment of a Digital Elevation Model based on TanDEM-X data” for the southwestern territory of Poland. The study area included: open terrain, urban terrain and forested terrain. Based on a set of 17,498 reference points acquired by airborne laser scanning, the mean errors of average heights and standard deviations were calculated for areas with a terrain slope below 2 degrees, between 2 and 6 degrees and above 6 degrees. The absolute accuracy of the IDEM data for the analysed area, expressed as a root mean square error (Total RMSE), was 0.77 m.
Go to article

Authors and Affiliations

Małgorzata Woroszkiewicz
Ireneusz Ewiak
Paulina Lulkowska
Download PDF Download RIS Download Bibtex

Abstract

The purpose of this study was to determine the spatial structure of vegetation on the repository of the mine “Fryderyk” in Tarnowskie Góry. Tested area was located in the Upper Silesian Industrial Region (a large industrial region in Poland). It was a unique refuge habitat – Natura2000; PLH240008. The main aspect of this elaboration was to investigate the possible use of geotechniques and generally available geodata for mapping LULC changes and determining the spatial structure of vegetation. The presented study focuses on the analysis of a spatial structure of vegetation in the research area. This exploration was based on aerial images and orthophotomaps from 1947, 1998, 2003, 2009, 2011 and airborne laser scanning data (2011, ISOK project). Forest succession changes which occurred between 1947 and 2011 were analysed. The selected features of vegetation overgrowing spoil heap “Fryderyk” was determined. The results demonstrated a gradual succession of greenery on soil heap. In 1947, 84% of this area was covered by low vegetation. Tree expansion was proceeding in the westerly and northwest direction. In 2011 this canopy layer covered almost 50% of the research area. Parameters such as height of vegetation, crowns length and cover density were calculated by an airborne laser scanning data. These analyses indicated significant diversity in vertical and horizontal structures of vegetation. The study presents some capacities to use airborne laser scanning for an impartial evaluation of the structure of vegetation.
Go to article

Authors and Affiliations

Marta Szostak
Piotr Wężyk
Marek Pająk
Paweł Haryło
Marek Lisańczuk
Download PDF Download RIS Download Bibtex

Abstract

Aerial thermography is performed from a low−cost aerial vehicle, copter type, for the acquisition of data of medium−size areas, such as neighbourhoods, districts or small villages. Thermographic images are registered in a mosaic subsequently used for the generation of a thermographic digital terrain model (DTM). The thermographic DTM can be used with several purposes, from classification of land uses according to their thermal response to the evaluation of the building prints as a function of their energy performance, land and water management. In the particular case of buildings, apart from their individual evaluation and roof inspection, the availability of thermographic information on a DTM allows for the spatial contextualization of the buildings themselves and the general study of the surrounding area for the detection of global effects such as heat islands.

Go to article

Authors and Affiliations

S. Lagüela
L. Díaz-Vilariño
D. Roca
H. Lorenzo
Download PDF Download RIS Download Bibtex

Abstract

Calculation of the effect of topography on the observed gravity becomes particularly important when modelling high-precision geoid. It requires a digital terrain model of appropriate resolution and accuracy. Various global, regional and local digital terrain models of different accuracy and resolution are recently available. Evaluation of the DTM used is required for verification and validation of its quality as well as for estimating accuracy of geoid model derived with considering the effect of topographic masses. Two DTMs: the SRTM3 of 3" x 3" resolution and the national DTM for Poland of l" x l" or l" x 2" resolution - called DTED2 - were evaluated with use of high-resolution local DTMs developed using digital photogrammetry of 25 m x 25 m as well as the regional model in Tatra mountains of 10 m x 10 m. Then the heights of almost 1000 GPS/levelling stations of Polish geodetic control were compared with the heights from the DTED2 model. The heights of over a million of gravity stations from gravity database, that were the basis of previous geoid modelling in Poland, were also compared with the heights from the DTED2 model. The effect of uncertainty of a DTM on estimation of mean gravity anomalies was discussed. In particular, the effect of replacing heights from gravity database with the heights from the DTED2 model in the process of calculating mean gravity anomalies, on the accuracy of geoid modelling was investigated. The use of the DTED2 model is at present recommended for determination of precise geoid model in Poland.
Go to article

Authors and Affiliations

Jan Kryński
ORCID: ORCID
Magdalena Mank
Małgorzata Grzyb
Download PDF Download RIS Download Bibtex

Abstract

The integration of geodetic and photogrammetric data has become a new tool that has expanded the existing measurement capabilities, as well as it found its application outside the geodetic sector. As a result, over the past decades, the process of topographic data acquisition has caused cartographic industry to move from classical surveying methods to passive and active detection methods. The introduction of remote sensing technology has not only improved the speed of data acquisition but has also provided elevation data for areas that are difficult to access and survey. The aim of the work is to analyse consistency of elevation data from the Georeference Database of Topographic Objects (Pol. Baza danych obiektów topograficznych – BDOT500) with data from airborne laser scanning (ALS) for selected 15 research areas located in the City of Kraków. The main findings reveal discrepancies between elevation data sources, potentially affecting the accuracy of various applications, such as flood risk assessment, urban planning, and environmental management. The research gap identified in the study might stem from the lack of comprehensive investigations into the consistency and accuracy of elevation data across different databases and technologies in urban areas. This gap highlights the need for a thorough examination of the reliability of various data sources and methods of urban planning, disaster management, and environmental analysis. The integration of diverse databases and technologies, like ALS and geodetic measurements, in various applications introduces potential discrepancies that can significantly impact decision-making and outcomes.
Go to article

Authors and Affiliations

Izabela Piech
1
ORCID: ORCID
Agnieszka Policht-Latawiec
1
ORCID: ORCID
Lenka Lackóová
ORCID: ORCID
Paulina Inglot
1 2

  1. University of Agriculture in Krakow, Faculty of Environmental Engineering and Land Surveying, al. Adama Mickiewicza 21, 31-120 Kraków, Poland
  2. Slovak University of Agriculture in Nitra, Faculty of Horticulture and Landscape Engineering, Department of Landscape Planning and Ground Consolidation, 949 76 Nitra, Slovak Republic

This page uses 'cookies'. Learn more