In the authors’ opinion, the issue of incorrectly functioning water insulation of foundation walls in the existing buildings in Poland is currently rather common. The paper includes a multicriteria analysis aimed at arranging the selected options of the foundation wall vertical water insulation technology in an existing model historic building using the weighted sum, entropy and AHP methods. Each of the studied solutions was evaluated in terms of the following criteria: costs of construction works, time of execution of construction works, popularity of using particular insulation options by other contractors, durability of the executed insulation and the degree of nuisance of the executed works
There is often a need to improve the taste of mineral water by reducing the sulphate ion content. It was found that for such an effect, nanofiltration (NF) process can be used. In the case, the proposed formula was assumed obtaining a mineral water with reduction of H2S and SO42- content through the following processes: stripping - UF/MF or rapid fi ltration - nanofiltration - mixing with raw water or filtration through calcium bed. The paper shows the results of the tests, with use of mineral waters and nanofiltration. Commercial nanofiltration membranes NF-270 Dow Filmtec and NF-DK GE Infrastructure Water&Process Technologies were applied. NF was carried out for mixed water from both water intakes (1 and 2), recovery of 50%, at transmembrane pressure of 0.8-1.2 MPa in the dead-end fi ltration mode. In addition, the permeate obtained in NF was filtered through a column fi lled with 1.0-3.0 mm limestone rock, in order to improve the composition of mineral water. The tested mineral water is the sulphate-chloride-sodium-calcium-magnesium in nature and contains 991 mg/L of SO42- and 2398 mg/L of TDS, while the permeate after NF showed the chloride - sodium hydrogeochemical type (TDS: 780-1470 mg/L, sulfate 10-202.7 mg/L, calcium 23-39.7 mg/L, magnesium 11-28 mg/L). As a result of water treatment in the NF process, high reduction of SO42- ions was obtained (79-98.7%), while the TDS was reduced in 51-64%. Because the process of NF allows for relatively high reduction of bivalent ions, a significant reduction in calcium ion content (84-88%) and magnesium (84-89%) has been also obtained. Monovalent ions were reduced to a lesser extent, i.e. sodium in 46% and bicarbonates in 39-64.1%. Despite obtaining the positive effect of the sulphate ions content reduction, the NF process significantly changed the mineralogy composition of water. The permeate filtration (DK-NF membrane) on the CaCO3 deposit led to a correction of the hydrogeochemical type of water from chloridesodium to chloride-bicarbonate-sodium. The concentration of calcium ions was increased by 60.5% and was 28.2 mg/L, and bicarbonate ions by 7.78% (increased to 195 mg/L). Based on a morphological assessment of the deposits in the SEM image and their chemical composition, the presence of gypsum crystals was detected on the surface of the NF-270 membrane. The deposits formed on the NF-DK membrane were of a completely different character as aggregations of iron and aluminium oxides/hydroxides were found. Such significant mineralogical differences between the secondary deposits crystallising on the surface of the membranes point to the impact of several factors, including membrane characteristics, concentration polarisation, mass transport mechanisms, etc.
This article aims to evaluate the potential application of prefabricated panels in energy retrofit of facades in the Portuguese building stock. The fundamentals of this study were part of Annex 50, which was an international ECBCS IEA project, with the purpose of developing an innovative concept of building renovation for the most representative buildings based on prefabricated systems. To analyze the potential application of energy retrofit using prefabricated panels, was important to know the reality of the existing building stock and its morphology. To know the reality of the building stock, an analysis was done based on the existing statistical data and to find the most representative residential buildings, target of the study, three criteria were defined: buildings built before 1990, with 2 to 6 floors and with renovation needs in the exterior envelope.
In the absence of statistical information about buildings morphology, a research work was done in the field. During the collection of data a methodology was developed in which each opening was classified according to a code with three parameters. In the end of the classification, 29 final codes were achieved and was verified that three types of panels have a higher probability of being applied.