This paper proposes an inverse method to obtain accurate measurements of the transient temperature of fluid. A method for unit step and linear rise of temperature is presented. For this purpose, the thermometer housing is modelled as a full cylindrical element (with no inner hole), divided into four control volumes. Using the control volume method, the heat balance equations can be written for each of the nodes for each of the control volumes. Thus, for a known temperature in the middle of the cylindrical element, the distribution of temperature in three nodes and heat flux at the outer surface were obtained. For a known value of the heat transfer coefficient the temperature of the fluid can be calculated using the boundary condition. Additionally, results of experimental research are presented. The research was carried out during the start-up of an experimental installation, which comprises: a steam generator unit, an installation for boiler feed water treatment, a tray-type deaerator, a blow down flashvessel for heat recovery, a steam pressure reduction station, a boiler control system and a steam header made of martensitic high alloy P91 steel. Based on temperature measurements made in the steam header using the inverse method, accurate measurements of the transient temperature of the steam were obtained. The results of the calculations are compared with the real temperature of the steam, which can be determined for a known pressure and enthalpy.

Go to article

Authors and Affiliations

Magdalena Jaremkiewicz
Download PDF Download RIS Download Bibtex

Abstract

This article presents the validation process of a brake FE model by means of temperature measured on a special stand using infrared technology. Unlike many other publications, the authors try to show the interaction between measurement technology and numerical modeling rather than only nice, perfectly correlated graphs. Some difficulties in choosing and using validation parameters are also pointed out and discussed. Finally, results of FE analyses are compared with measured data, followed by explanation of applied numerical technology and estimation of validation process effectiveness.

Go to article

Authors and Affiliations

Paweł Baranowski
Krzysztof Damaziak
Jerzy Malachowski
Lukasz Mazurkiewicz
Henryk Polakowski
Tadeusz Piatkowski
Mariusz Kastek
Download PDF Download RIS Download Bibtex

Abstract

The article presents a new discretization method of a continuous-time linear model of sensor dynamics. It can be useful to reduce measuring errors related to the inertia of the sensor. For example it is important in the measurement of rapid processes as temperature changes in combustion chambers, or for shortening the time needed to establish the sensor readings in a transition state. There is assumed that sensor dynamics can be approximated by linear differential equation or transfer function. The searched coefficients of equivalent difference equation or discrete transfer function are obtained from Taylor expansion of a sensor output signal and then on the solution of the linear set of equations. The method does not require decomposition of sensor transfer function for zeros and poles and can be applied to the case of transfer function with zeros equal to zero. The method was used to compensate the dynamics of sensor measuring fast signals. The Bode characteristics of a compensator were compared with others derived using classical methods of discretization of linear models. Additionally, signals in time were presented to show the dynamic error before and after compensation.
Go to article

Authors and Affiliations

Sławomir Gryś
1
Waldemar Minkina
2

  1. University of Technology, Faculty of Electrical Engineering, Poland
  2. Jan Dlugosz University in Czestochowa, Faculty of Science and Technology, Poland
Download PDF Download RIS Download Bibtex

Abstract

Distribution of the exhaust gas temperature within the furnace of a grate boiler greatly depends on its operating parameters such as output. It has a considerably different character than temperature distributions in other types of boilers (with pulverised or fluidised bed), as it varies considerably across the chamber. Results presented in this paper have been obtained through research of a grate-fired hot water boiler with a nominal rating of some 30 MW. Measurements have been taken by introducing temperature sensors into prearranged openings placed in the boiler side walls. Investigation has been carried out for different output levels. Tests involved thermocouples in ceramic coating and aspirated thermocouples. The latter were used to eliminate influence of radiative heat transfer on measured results. Values obtained with both methods have been cross-checked.
Go to article

Authors and Affiliations

Piotr Krawczyk
Krzysztof Badyda
Jacek Szczygieł
Szczepan Młynarz
Download PDF Download RIS Download Bibtex

Abstract

The paper presents the solution to a problem of determining the heat flux density and the heat transfer coefficient, on the basis of temperature measurement at three locations in the flat sensor, with the assumption that the heat conductivity of the sensor material is temperature dependent. Three different methods for determining the heat flux and heat transfer coefficient, with their practical applications, are presented. The uncertainties in the determined values are also estimated.

Go to article

Authors and Affiliations

Dawid Taler
Sławomir Grądziel
Jan Taler
Download PDF Download RIS Download Bibtex

Abstract

The paper presents the application of liquid crystal thermography for temperature determination and visualisation of two phase flow images on the studied surface. Properties and applications of thermochromic liquid crystals are discussed. Liquid crystals were applied for two-dimensional detection of the temperature of the heating foil forming one of the surfaces of the minichannel along which the cooling liquid flowed. The heat flux supplied to the heating surface was altered in the investigation and it was accompanied by a change in the color distribution on the surface. The accuracy of temperature measurements on the surface with liquid crystal thermography is estimated. The method of visualisation of two-phase flow structures is described. The analysis of monochrome images of flow structures was employed to calculate the void fraction for some cross-sections. The flow structure photos were processed using Corel graphics software and binarized. The analysis of phase volumes employed Techsystem Globe software. The measurement error of void fraction is estimated.

Go to article

Authors and Affiliations

Magdalena Piasecka
Download PDF Download RIS Download Bibtex

Abstract

Photovoltaic panels have a non-linear current-voltage characteristics to produce the maximum power at only one point called the maximum power point. In the case of the uniform illumination a single solar panel shows only one maximum power, which is also the global maximum power point. In the case an irregularly illuminated photovoltaic panel many local maxima on the power-voltage curve can be observed and only one of them is the global maximum. The proposed algorithm detects whether a solar panel is in the uniform insolation conditions. Then an appropriate strategy of tracking the maximum power point is taken using a decision algorithm. The proposed method is simulated in the environment created by the authors, which allows to stimulate photovoltaic panels in real conditions of lighting, temperature and shading.

Go to article

Authors and Affiliations

Janusz Mroczka
Mariusz Ostrowski
Download PDF Download RIS Download Bibtex

Abstract

Under steady-state conditions when fluid temperature is constant, temperature measurement can be accomplished with high degree of accuracy owing to the absence of damping and time lag. However, when fluid temperature varies rapidly, for example, during start-up, appreciable differences occur between the actual and measured fluid temperature. These differences occur because it takes time for heat to transfer through the heavy thermometer pocket to the thermocouple. In this paper, a method for determinig transient fluid temperature based on the first-order thermometer model is presented. Fluid temperature is determined using a thermometer, which is suddenly immersed into boiling water. Next, the time constant is defined as a function of fluid velocity for four sheated thermocouples with different diameters. To demonstrate the applicability of the presented method to actual data where air velocity varies, the temperature of air is estimated based on measurements carried out by three thermocouples with different outer diameters. Lastly, the time constant is presented as a function of fluid velocity and outer diameter of thermocouple.
Go to article

Authors and Affiliations

Magdalena Jaremkiewicz
Download PDF Download RIS Download Bibtex

Abstract

Power system state estimation is a process of real-time online modeling of an electric power system. The estimation is performed with the application of a static model of the system and current measurements of electrical quantities that are encumbered with an error. Usually, a model of the estimated system is also encumbered with an uncertainty, especially power line resistances that depend on the temperature of conductors. At present, a considerable development of technologies for dynamic power line rating can be observed. Typically, devices for dynamic line rating are installed directly on the conductors and measure basic electric parameters such as the current and voltage as well as non-electric ones as the surface temperature of conductors, their expansion, stress or the conductor sag angle relative to the plumb line. The objective of this paper is to present a method for power system state estimation that uses temperature measurements of overhead line conductors as supplementary measurements that enhance the model quality and thereby the estimation accuracy. Power system state estimation is presented together with a method of using the temperature measurements of power line conductors for updating the static power system model in the state estimation process. The results obtained with that method have been analyzed based on the estimation calculations performed for an example system - with and without taking into account the conductor temperature measurements. The final part of the article includes conclusions and suggestions for the further research.