Search results

Filters

  • Journals
  • Authors
  • Keywords
  • Date
  • Type

Search results

Number of results: 21
items per page: 25 50 75
Sort by:
Download PDF Download RIS Download Bibtex

Abstract

The transition to a zero-carbon economy is the inclusive growth story of the twenty-first century. It needs to be managed with effective and cohesive policies, whilst recognizing that sustainable development, inclusive growth and climate action are interwoven and mutually supportive.

Go to article

Authors and Affiliations

Nicholas Stern
Download PDF Download RIS Download Bibtex

Abstract

The zero attraction affine projection algorithm (ZA-APA) achieves better performance in terms of convergence rate and steady state error than standard APA when the system is sparse. It uses l1 norm penalty to exploit sparsity of the channel. The performance of ZA-APA depends on the value of zero attractor controller. Moreover a fixed attractor controller is not suitable for varying sparsity environment. This paper proposes an optimal adaptive zero attractor controller based on Mean Square Deviation (MSD) error to work in variable sparsity environment. Experiments were conducted to prove the suitability of the proposed algorithm for identification of unknown variable sparse system.

Go to article

Authors and Affiliations

S. Radhika
A. Chandrasekar
S. Nirmalraj
Download PDF Download RIS Download Bibtex

Abstract

The increased power density, reduced switching losses with minimum electromagnetic interference (EMI), and high efficiency are essential requirements of power converters. To achieve these characteristics, soft power converters employing soft switching techniques are indispensable. In this paper, a ZCS/ZVS PWM AC/DC converter topology has been emphasized, which finds applications in high power systems such as automobile battery charging and renewable energy systems. This converter scheme maintains zero current and zero voltage switching conditions at turn on and turn off moments of semiconductor switches, respectively and soft operation of rectifier diodes that lead to negligible switching and diode reverse recovery losses. Moreover, it improves power quality and presents high input power factor, low total harmonic distortion of the input current (THDI) and improved efficiency. The validity of theoretical analysis of the proposed converter has been carried out experimentally on a 10 kW laboratory prototype. Experimental results prove that the soft switching operation of the semiconductor switches and diodes is maintained at 98.6% rated load efficiency. In addition, the performance evaluation has been performed by comparative analysis of the proposed converter with some prior art high power AC/DC converters. Efficiencies of the proposed and prior art high power topologies have been determined for different load conditions. The highest efficiency, power factor and lower THDI of the proposed converter topology complies with international standards.

Go to article

Authors and Affiliations

A. Ali
J. Chuanwen
M.M. Khan
S. Habib
Y. Ali
Download PDF Download RIS Download Bibtex

Abstract

The article introduces an innovative approch for the inspection challenge that represents a generalization of the classical Traveling Salesman Problem. Its priciple idea is to visit continuous areas (circles) in a way, that minimizes travelled distance. In practice, the problem can be defined as an issue of scheduling unmanned aerial vehicle which has discrete-continuous nature. In order to solve this problem the use of local search algorithms is proposed.

Go to article

Authors and Affiliations

Radosław Grymin
Wojciech Bożejko
Zenon Chaczko
Jarosław Pempera
Mieczysław Wodecki
Download PDF Download RIS Download Bibtex

Abstract

Technologia przepuszczalnych reaktywnych barier (PRB) należy do metod remediacji wód gruntowych. W technologii tej zanieczyszczenia usuwane są bezpośrednio w warstwie wodonośnej poprzez przepływ skażonego strumienia wód gruntowych przez wypełnioną odpowiednim materiałem (aktywnym) barierę aktywną. W artykule przedstawiono problemy związane z tworzeniem się osadów w żelazie metalicznym stosowanymjako material aktywny technologii PRB. Osady te mogą zmniejszać aktywność materiału i jego zdolność filtracyjną. Tworzeniu się osadów mogą towarzyszyć zmiany pH, potencjału redox oraz stężenia tlenu. Zmiany te były obserwowane w badaniach laboratoryjnych przedstawionych w artykule. Ponadto w artykule przedstawiono i udowodniono następującą zasadę: aby zwiększyć skuteczność działania typu Funnel-and-Gate technologii PRB przez zwiększenie szerokości strefy oczyszczania, stosunek współczynnika filtracji materiału aktywnego do współczynnika filtracji warstwy wodonośnej (k,,,/k,ą) powinien przyjąć wartość 6. Ze względu na tworzenie się osadów w żelazie metalicznym, które mogą zmniejszyć jego zdolność filtracyjną, założono jednak, iż stosunek ten powinien wynosić I O. Wartość ta daje pewność, że zmniejszenie się wartości współczynnika filtracji materiału aktywnego na skutek tworzenia się osadów, nie wpłynie w znaczący sposób na szerokość strefy oczyszczania. Przedstawione rozwiązanie może zapewnić skuteczne i długotrwale oczyszczanie wód gruntowych w typie Funnel-and-Gate technologii PRB.
Go to article

Authors and Affiliations

Tomasz Suponik
ORCID: ORCID
Download PDF Download RIS Download Bibtex

Abstract

The removal of nitrates from aqueous solutions is cumbersome because of their high solubility in water. The use of zero-valent iron (ZVI) for the reduction of nitrates is the chemical process and it is an alternative method to the biological ones. The aim of the present study was to evaluate the eff ectiveness of nitrates removal from water solution by using the ZVI process. The process was coupled with the removal of COD, phosphates and turbidity by using by-products of nitrates reduction. Batch tests were performed to evaluate the eff ectiveness of ZVI in the removal of nitrates from aqueous solutions. The eff ectiveness of nitrates removal was analyzed after 5, 10, 20, 30 and 60 min. and compared to the initial concentration of pollutants. Simultaneously analysis of ammonium nitrogen and nitrites was controlled to identify products of nitrates reduction under various pH. The removal of COD, phosphates and turbidity was also performed in batch tests. The eff ectiveness of the emoval by using three types of chemicals was compared – PIX, FeSO4, and waste Fe2+/Fe3+ from the ZVI process. The results obtained in the study indicate that ZVI can be eff ectively used in the treatment of water polluted with nitrates and the by-products of the process could be further applied in the removal of COD, phosphates and turbidity. Based on the results the method should be advised as a promising alternative to the technologies used nowadays under technical scale as a technology that fits with a circular economy.

Go to article

Authors and Affiliations

Ewa Wiśniowska
1
Maria Włodarczyk-Makuła
1

  1. Częstochowa University of Technology, Poland
Download PDF Download RIS Download Bibtex

Abstract

In Polish coal mining, medium voltage power distribution networks operate with an insulated neutral point. Zero-sequence current transformers are the basic sensors that generate input signals for earth-fault protection relays. In the literature, the problem of frequency response analysis of various types of current transformers has been examined many times, e.g. [1] [2], but not for zero-sequence current transformers so far. As part of the work, two types of zero-sequence current transformers in the range from 0.1 Hz to 100 kHz were tested. Both the change of the current ratio and the angular shift between the transformer secondary current and the total primary current were analyzed.

Go to article

Authors and Affiliations

Krzysztof Kuliński
Adam Heyduk
Download PDF Download RIS Download Bibtex

Abstract

The purpose of this paper is to propose a model of a novel quasi-resonant boost converter with a tapped inductor. This converter combines the advantages of zero voltage quasi-resonant techniques and different conduction modes with the possibility of obtaining a high voltage conversion ratio by using a tapped inductor, which results in high converter efficiency and soft switching in the whole output power range. The paper contains an analysis of converter operation, a determination of voltage conversion ratio and the maximum voltage across power semiconductor switches as well as a discussion of control methods in discontinuous, critical, and continuous conduction modes. In order to verify the novelty of the proposed converter, a laboratory prototype of 300 W power was built. The highest efficiency η  = 94.7% was measured with the output power Po =  260 W and the input voltage Vin = 50 V. The lowest efficiency of 90.7% was obtained for the input voltage Vin  = 30 V and the output power Po = 75 W. The model was tested at input voltages (30–50) V, output voltage 380 V and maximum switching frequency 100 kHz.

Go to article

Bibliography

  1.  M. Forouzesh, Y.P. Siwakoti, S.A. Gorji, F. Blaabjerg, and B. Lehman, “Step-Up DC-DC Converters: A Comprehensive Review of Voltage-Boosting Techniques, Topologies, and Applications”, IEEE Trans. Power Electron. 32(12), 9143‒9178 (2017), doi: 10.1109/ TPEL.2017.2652318.
  2.  W. Li and X. He, “Review of Nonisolated High-Step-Up DC/DC Converters in Photovoltaic Grid-Connected Applications”, IEEE Trans. Ind. Electron. 58(4), 1239‒1250 (2011), doi: 10.1109/TIE.2010.2049715.
  3.  H. Liu, H. Hu, H. Wu, Y. Xing, and I. Batarseh, “Overview of High-Step-Up Coupled-Inductor Boost Converters”, IEEE IEEE J. Emerg. Sel. Top. Power Electron. 4(2), 689‒704 (2016), doi: 10.1109/JESTPE.2016.2532930.
  4.  A. Tomaszuk and A. Krupa, “High efficiency high step-up DC/DC converters – a review”, Bull. Pol. Ac.: Tech. 59(4), 475‒483 (2011), doi: 10.2478/v10175-011-0059-1.
  5.  W. Janke, M. Bączek, and J. Kraśniewski, “Input characteristics of a non-ideal DC-DC flyback converter”, Bull. Pol. Ac.: Tech. 67(5), 841‒849 (2019), doi: 10.24425/bpasts.2019.130884.
  6.  F.C. Lee, “High-frequency quasi-resonant converter technologies”, Proc. IEEE 76(4), 377‒390 (1988), doi: 10.1109/5.4424.
  7.  W.A. Tabisz, P.M. Gradzki, and F.C.Y. Lee, “Zero-voltage-switched quasi-resonant buck and flyback converters-experimental results at 10 MHz”, IEEE Trans. Power Electron. 4(2), 194‒204, 1989, doi: 10.1109/63.24904.
  8.  M. Harasimczuk and A. Borchert, “Single switch quasi-resonant ZVS converter with tapped inductor”, Prz. Elektrotechniczny 3, 44‒48 (2018).
  9.  S. Sathyan, H.M. Suryawanshi, M.S. Ballal, and A.B. Shitole, “Soft-Switching DC-DC Converter for Distributed Energy Sources With High Step-Up Voltage Capability”, IEEE Trans. Ind. Electron. 62(11), 7039‒7050 (2015), doi: 10.1109/TIE.2015.2448515.
  10.  T.F. Wu, Y.S. Lai, J.C. Hung, and Y.M. Chen, “Boost Converter With Coupled Inductors and Buck-Boost Type of Active Clamp”, IEEE Trans. Ind. Electron. 55(1), 154‒162 (2008), doi: 10.1109/TIE.2007.903925.
  11.  J.H. Yi, W. Choi, and B.H. Cho, “Zero-Voltage-Transition Interleaved Boost Converter With an Auxiliary Coupled Inductor”, IEEE Trans. Power Electron. 32(8), 5917‒5930 (2017), doi: 10.1109/TPEL.2016.2614843.
  12.  Y. Chen, Z. Li, and R. Liang, “A Novel Soft-Switching Interleaved Coupled-Inductor Boost Converter With Only Single Auxiliary Circuit”, IEEE Trans. Power Electron. 33(3), 2267‒2281 (2018), doi: 10.1109/TPEL.2017.2692998.
  13.  R. Stala et al., “A family of high-power multilevel switched capacitor-based resonant DC-DC converters – operational parameters and novel concepts of topologies”, Bull. Pol. Ac.: Tech. 65(5), 639‒651 (2017).
  14.  M. Harasimczuk, “A QR-ZCS Boost Converter With Tapped Inductor and Active Edge-Resonant Cell”, IEEE Trans. Power Electron. 35(12), 13085‒13095 (2020), doi: 10.1109/TPEL.2020.2991363.
  15.  M. Harasimczuk, “Przekształtniki podwyższające napięcie z dławikami dzielonymi”, PL Patent, Poland, P.423354, 2017.
Go to article

Authors and Affiliations

Jakub Dawidziuk
1
ORCID: ORCID
Michał Harasimczuk
2
ORCID: ORCID

  1. Department of Automatic Control and Robotics, Bialystok University of Technology, ul. Wiejska 45D, 15-351 Bialystok, Poland
  2. Department of Electrical Engineering, Power Electronics and Electrical Power Engineering, Bialystok University of Technology, ul. Wiejska 45D, 15-351 Bialystok, Poland
Download PDF Download RIS Download Bibtex

Abstract

Poles and zeros assignment problem by state feedbacks in positive continuous-time and discrete-time systems is analyzed. It is shown that in multi-input multi-output positive linear systems by state feedbacks the poles and zeros of the transfer matrices can be assigned in the desired positions. In the positive continuous-time linear systems the feedback gain matrix can be chosen as a monomial matrix so that the poles and zeros of the transfer matrices have the desired values if the input matrix B is monomial. In the positive discrete-time linear systems to solve the problem the matrix B can be chosen monomial if and only if in every row and every column of the n x n system matrix A the sum of n-1 its entries is less than one. Key words: assignment, pole, zero, transfer matrix, linear, positive, system, state feedback
Go to article

Bibliography

[1] E. Antsaklis and A. Michel: Linear Systems. Birkhauser, Boston, 2006.
[2] L. Farina and S. Rinaldi: Positive Linear Systems: Theory and Applications. J. Wiley & Sons, New York, 2000.
[3] T. Kaczorek: Linear Control Systems, vol. 2. Research Studies Press LTD., J. Wiley, New York, 1992.
[4] T. Kaczorek: Positive 1D and 2D Systems. London, UK, Springer-Verlag, 2002.
[5] T. Kaczorek: Selected Problems of Fractional Systems Theory. Berlin, Germany, Springer-Verlag, 2011.
[6] T. Kaczorek and K. Rogowski: Fractional Linear Systems and Electrical Circuits, Studies in Systems, Decision and Control, Vol. 13. Springer, 2015.
[7] T. Kailath: Linear systems. Prentice Hall, Englewood Cliffs, New York, 1980.
[8] R.E. Kalman: Mathematical description of linear systems. J. SIAM Control, 1(2), (1963), 152–192, DOI: 10.1137/0301010.
[9] R.E. Kalman: On the general theory of control systems. Proc. First International Congress on Automatic Control, London, UK, Butterworth, (1960), 481–493,
[10] J. Klamka: Controllability of Dynamical Systems. Kluwer, Acadenic Publ., Dordrecht 1991.
[11] H. Rosenbrock: State-Space and Multivariable Theory. New York, USA, J. Wiley, 1970.
[12] S.M. Zak: Systems and Control. New York, Oxford University Press, 2003.
Go to article

Authors and Affiliations

Tadeusz Kaczorek
1
ORCID: ORCID

  1. Białystok University of Technology, Faculty of Electrical Engineering, Wiejska 45D, 15-351 Białystok, Poland
Download PDF Download RIS Download Bibtex

Abstract

Presented article contain the teachers opinions of the perceived social expectations in relation to their own expectations of both the institutions of school and local educational authorities. The starting point is a thesis that asymmetrical and disproportionate expectations conducive to the construction of the reduced school reality a specified group of students. as reality shows school does not always reflect the social expectations, which is closely connected with the attitudes of teachers in mainstream schools. however, their expectations of working conditions and the same students with disabilities often remain inconsistent. To identify and interpret the reality that create the appearance of the school, the topic is examined in the context of the concept of the reduced space and the theory of games.

Go to article

Authors and Affiliations

Dorota Prysak
Download PDF Download RIS Download Bibtex

Abstract

Although the explicit commutativitiy conditions for second-order linear time-varying systems have been appeared in some literature, these are all for initially relaxed systems. This paper presents explicit necessary and sufficient commutativity conditions for commutativity of second-order linear time-varying systems with non-zero initial conditions. It has appeared interesting that the second requirement for the commutativity of non-relaxed systems plays an important role on the commutativity conditions when non-zero initial conditions exist. Another highlight is that the commutativity of switched systems is considered and spoiling of commutativity at the switching instants is illustrated for the first time. The simulation results support the theory developed in the paper.

Go to article

Authors and Affiliations

Mehmet Emir Koksal
Download PDF Download RIS Download Bibtex

Abstract

We theoretically propose a method to achieve an optimum absorbing material through a modulus-near-zero (MNZ) metamaterial immersed in air or water with a change in slit width part. The destructive interference has paved the way to achieve perfect absorption (PA). Depending upon theoretical analysis, an acoustic metamaterial (AMMs) that supports resonance with a monopole (140 Hz) is developed to construct a low-frequency sound-absorbing technology. The dissipative loss effect can be by attentively controlling onto slit width to achieve perfect absorption. When there are thin slit width and visco-thermal losses in the structure, it is observed that they lead to high absorption. We use finite element simulations via COMSOL Multiphysics software to theoretical measurement in impedance tube and show the influence of structural parameters in both mediums. The results are of extraordinary correspondence at low frequency to achieve optimum perfect absorption (99%). That might support AMMs to actual engineering-related applications in the process of mitigating noise, slow sound trapping, notch filtering, energy conversion, and time reversal technology.
Go to article

Authors and Affiliations

Fatma Nafaa Gaafer
1

  1. Department of Science, College of Basic Education, Wasit University, Iraq
Download PDF Download RIS Download Bibtex

Abstract

Transforming the energy sector is necessary but not sufficient to prevent a climate catastrophe.
Go to article

Authors and Affiliations

Jan Kozłowski
1

  1. Institute of Environmental Sciences, Jagiellonian University in Kraków, Poland
Download PDF Download RIS Download Bibtex

Abstract

Due to the extensive use of nonlinear power consumers, there is currently an urgent problem of high harmonic content in power supply networks. The paper provides experimental investigations and a study of the nature of the change in the main harmonic components of the current in the neutral working wire of a three-phase four-wire network with a voltage of 0.38 kV. The purpose of this study is to compare the load readings on the amplitude-phase-frequency characteristics of the current in the neutral working wire of the 0.38 kV network with the linear and non-linear load. To study the effect of load changes on the amplitude-phase-frequency characteristics of currents in the linear and zero working wires at the input of the load node, measurements were carried out by certified electrical measuring instruments. The analysis of the results obtained for the load node whose power was formed mainly by a lighting system with fluorescent and LED lamps and a system of office electrical receivers (computers, copiers, printers, scanners, etc.) was performed. It can be concluded that a current comparable to the currents of the linear wires of the network flows from the load node with the predominant nonlinear power receivers through the zero-working wire. At the same time, in the zero-working wire of the network, the third harmonic currents prevail over the main frequency currents.
Go to article

Bibliography

[1] Golub I., Boloev E., Methods of linear and nonlinear state estimation of distribution network, Proceedings of E3S Web of Conferences, Irkutsk, Russian Federation (2018).
[2] Grigoriev O.A., Petukhov V.S., Sokolov V.A., Krasilov I.A., On the impact of electronic equipment on power networks, Computer Press 1, http://www.compress.ru/article.aspx?id=9553&iid=404 (2003).
[3] Om P.M., Abdul G.S., Neeraj G., Acritical review of detection and classification of power quality events, Renewable and Sustainable Energy Reviews, no. 41, pp. 495–505 (2015).
[4] Daus Y.V., Yudaev I.V., Taranov M.A., Voronin S.M., Gazalov V.S., Reducing the costs for consumed electricity through the solar energy utilization, International Journal of Energy Economics and Policy, vol. 9, no. 2, pp. 19–23 (2019).
[5] Ded A.V., To the problem of the current state of the levels of indices of asymmetry of voltages and currents in networks of 0.4 kV, Omsk Scientific Herald, vol. 2, no. 152, pp. 63–65 (2017).
[6] Kosoukhov F.D., Vasiliev N.V., Kuznetsova E.S., New scientific directions in energy saving in threephase transformers and four-wire lines with asymmetric, non-linear and reactive loads, News of St. Petersburg State Agrarian University, vol. 2, no. 47, pp. 300–309 (2017).
[7] Belitsky A.A., Shklyarsky Y.E., Estimation of additional power losses in networks with non-linear and asymmetric load, Bulletin of Tula State University, Technical Science, no. 7, pp. 86–93 (2018).
[8] Deokar S.A., Waghmare L.M., Analysis of distribution transformer performance un-der non-linear balanced load conditions and it’s remedial, International Journal of Technology and Advanced Engineering, vol. 1, no. 2, pp. 152–161 (2011).
[9] Corasaniti V.F., Barbieri M.B., Arnera P.L., Valla M.I., Characteristics of the loads in medium voltage networks from the point of view using active filters, in IEEE PES Transmission and Distribution Conference and Exposition, pp. 1–7 (2006).
[10] Ge J., Shuai Z., Zhao H., Shen Z.J., Generalized power and current control for three-phase fourwire converter under unbalanced grid conditions, Procceding of the IECON, Lisbon, Portugal, pp. 3900–3905 (2019).
[11] Szulborski M., Kolimas Ł., Łapczynski S., Szczęśniak P., Single phase UPS systems loaded with nonlinear circuits: Analysis of topology in the context of electric power quality, Archives of Electrical Engineering, vol. 68, no. 4, pp. 787–802 (2019).
[12] Barutskov I.B., Vdovenko S.A., Tsygankov E.V., Harmonic distortion during operation of frequency converters, Chief Power Engineer, no. 6, pp. 5–13 (2011).
[13] Om P.M., Abdul G.S., Topological aspects of power quality improvement techniques: A comprehensive overview, Renewable and Sustainable Energy Reviews, no. 58, pp. 1129–1142 (2016).
[14] Bodart M., Denejer A., Keppens A., Rikart U.R., Rojzin B., Characteristics of compact fluorescent lamps with integrated ballasts and their comparison with incandescent lamps, Lighting Engineering, no. 2, pp. 18–24 (2010).
[15] Suslov K.V., Stepanov V.S., Solonina N.N., Effect of high harmonics on electricity consumers in distribution networks, in 2013 International Symposium on Electromagnetic Compatibility (EMC Europe 2013), pp. 841–845 (2013).
[16] Fursanov M.I., Zalotoy A.A., Makarevich V.V., Calculation of technological consumption (loss) of electricity in modern 0.38-10 kV electrical distribution networks, Energetika, Proceedings of CIS Higher Education Institutions and Power Engineering Associations, vol. 61, no. 5, pp. 408–422 (2018).
[17] Florkowski M., Florkowska B., Zydron P., High voltage harmonics induced modifications of PD phase-resolved patterns, Archives of Electrical Engineering, vol. 67, no. 2, pp. 231–246 (2018).
[18] European Standard EN 62040-3, https://files.stroyinf.ru/Data/704/70439.pdf (2018).
[19] Zeng X.J., Zhai H.F., Wang M.X., Yang M., Wang M.Q., A system optimization method for mitigating three-phase imbalance in distribution network, International Journal of Electrical Power and Energy Systems, no. 113, pp. 618–633 (2019).
Go to article

Authors and Affiliations

Igor V. Yudaev
1
Evgeny V. Rud
2
Mikhail A. Yundin
1
Tamara Z. Ponomarenko
2
Aleksandra M. Isupova
1

  1. Azov-Black Sea Engineering Institute of Don State Agrarian University, Russia
  2. ICPE Energy Institute for Advanced Studies of the PJSC “Kubanenergo”, Russia
Download PDF Download RIS Download Bibtex

Abstract

In this work, two robust zeroing neural network (RZNN) models are presented for online fast solving of the dynamic Sylvester equation (DSE), by introducing two novel power-versatile activation functions (PVAF), respectively. Differing from most of the zeroing neural network (ZNN) models activated by recently reported activation functions (AF), both of the presented PVAF-based RZNN models can achieve predefined time convergence in noise and disturbance polluted environment. Compared with the exponential and finite-time convergent ZNN models, the most important improvement of the proposed RZNN models is their fixed-time convergence. Their effectiveness and stability are analyzed in theory and demonstrated through numerical and experimental examples.
Go to article

Authors and Affiliations

Peng Zhou
1
Mingtao Tan
2
ORCID: ORCID

  1. College of Electronic Information and Automation, Guilin University of Aerospace Technology, Guilin 541004, China
  2. School of Computer and Electrical Engineering, Hunan University of Arts and Science, Changde 415000, China
Download PDF Download RIS Download Bibtex

Abstract

In this study, different amounts of tantalum carbide (TaC) powders (5, 10 and 15 wt.%) are added to Vanadis 4 Extra steel powders. The composite powders are sintered at 1260, 1280, 1300, 1320, 1340 and 1360°C for 1 h, respectively. The experimental results showed that good mechanical properties (hardness 79.7 HRA, TRS 2246 MPa) were obtained by the addition of 10% TaC sintered at 1320°C for 1 h. Furthermore, the optimal sintered V4ES/TaC (Vanadis 4 Extra steel / TaC) composites after sub-zero treatment possess the highest hardness (80.9 HRA) and transverse rupture strength (TRS) values (2445 MPa), as well as a better polarization resistance (658.99 Ω·cm2). After sub-zero treatment, the VC carbides decompose and re-precipitate refined VC carbides within the grains (VC carbides are formed in steel powder); moreover, the TaC particles are still uniformly distributed around the grain boundaries, which results in dispersion strengthening and precipitation hardening. The results clearly reveal that sub-zero heat treatment effectively improves the microstructure and strengthens the V4ES/TaC composite.

Go to article

Authors and Affiliations

Kuo-Tsung Huang
ORCID: ORCID
Shih-Hsien Chang
ORCID: ORCID
Chan-Yu Chuang
Download PDF Download RIS Download Bibtex

Abstract

The manuscript presents the condition of circular economy in Poland in diversified approach: subjective (waste streams, energy), sectoral (construction, wastewater treatment, coal energy), related to the resources (phosphorous and anthropogenic minerals) and considering proper energy management (almost zero energy buildings). The achievements reached in different sectors as well as the requirements towards implementation of CE are presented. The advancement of recycling technologies does not deviate from the global level, in terms of areas specific to Poland. Limiting the exploitation of natural resources and usage of new materials as well as producing more durable products are of CE concern. Also energy and heat recovery in buildings and technological processes (e.g. during wastewater treatment), ways of utilization of combustion by-products and water decarbonization waste are described. The implementation of CE in Poland needs not only research and technical activities, but also the modification of technological processes, the right policy, overcoming crosssectoral barriers, developing legal regulations and support schemes for CE.

Go to article

Authors and Affiliations

Zbigniew Kledyński
ORCID: ORCID
Anna Bogdan
Wioletta Jackiewicz-Rek
Krystyna Lelicińska-Serafin
Agnieszka Machowska
ORCID: ORCID
Piotr Manczarski
Dagmara Masłowska
Anna Rolewicz-Kalińska
Joanna Rucińska
Tomasz Szczygielski
Justyna Walczak
Małgorzata Wojtkowska
Monika Zubrowska-Sudol
Download PDF Download RIS Download Bibtex

Abstract

In order to minimize the receiver complexity and improve the performance of the spectral amplitude coding - optical code division multiple access system, a novel one-dimensional zero cross-correlation code using Pascal’s triangle matrix has been suggested. This research article shows that the position of chip “1” in the code sequences is one of the important factors affecting system performance. In fact, mathematical results show that, for the all-wavelength direct detection, it is possible to reduce the number of filters without sacrificing system performance. In addition, compared to one-wavelength direct detection, the signal-to-noise ratio value is increased with an increasing weight by using wide-bandwidth filters as decoders. Performance of the proposed system in terms of the minimum bit error rate is validated using the OptiSystem software. Compared with the previous systems at 622 Mbps, the suggested system gave the best values of bit error rate of around 10−43, 10−35, and 10−26 for higher, medium, and lower service demand, respectively.
Go to article

Bibliography

  1. Garba, A. A., Yim, R. M. H., Bajcsy, J. & Chen, L. R. Analysis of optical CDMA signal transmission: capacity limits and simulation results. EURASIP J. Appl. Signal Process. 10, 1603–1616 (2005). https://doi.org/10.1155/ASP.2005.1603
  2. Stok, A. & Sargent, E. H. The role of optical CDMA in access networks. IEEE Commun. Mag. 40, 83–87 (2002). https://doi.org/10.1109/MCOM.2002.1031833
  3. Chen, K. S., Chen, Y. C. & Liao, L. G. Advancing high-speed transmissions over OCDMA networks by employing an intelligently structured receiver for noise mitigation. Appl. Sci. 8, 1–14 (2018). https://doi.org/10.3390/app8122408
  4. Kaur, S. & Singh, S. Review on developments in all-optical spectral amplitude coding techniques. Opt. Eng. 57, 116102 (2018). https://doi.org/10.1117/1.oe.57.11.116102
  5. Gupta, S. & Goel. A. New bipolar spectral amplitude code for cardinality enhancement in OCDMA network. J. Opt. 49, 1–8 (2020). https://doi.org/10.1007/s12596-020-00589-4
  6. Driz, S. & Djebbari, A. Performance evaluation of sub-carrier multiplexed SAC-OCDMA system using optimal modulation index. J. Opt Commun. 40, 83–92 (2019). https://doi.org/10.1515/joc-2017-0044
  7. Aldhaibani, A. O., Aljunid, S. A., Anuar, M. S. & Arief, A. R. Increasing performance of SAC-OCDMA by combine OFDM technique. J. Theor. Appl. Inf. Technol. 66, 634–637 (2014).
  8. Ouis, E., Driz, S. & Fassi, B. Enhancing confidentiality protection for ZCZ-OCDMA network using line selection and wavelength conversion based on SOA. J. Opt. Commun. 000010151520200089 (2020). https://doi.org/10.1515/joc-2020-0089
  9. Jyoti, V. & Kaler, R. S. Security enhancement of OCDMA system against eavesdropping using code-switching scheme. Optik 122, 787–791(2011). https://doi.org/10.1016/j.ijleo.2010.05.027
  10. Moghaddasi, M., Seyedzadeh, S., Glesk, I., Lakshminarayana, G. & Anas, S. B. A. DW-ZCC code based on SAC–OCDMA deploying multi-wavelength laser source for wireless optical networks. Opt. Quant. Electron. 49, 393 (2017). https://doi.org/10.1007/s11082-017-1217-y
  11. Morsy, M. A. Analysis and design of weighted MPC in incoherent synchronous OCDMA network. Opt. Quant. Electron. 50, 387 (2018). https://doi.org/10.1007/s11082-018-1657-z
  12. Abd El-Mottaleb, S. A., Fayed, H. A., Aly, M. H., Rizk, M. R. & Ismail, N. E. An efficient SAC-OCDMA system using three different codes with two different detection techniques for maximum allowable users, Opt. Quant. Electron. 51, 354 (2019). https://doi.org/10.1007/s11082-019-2065-8
  13. Fassi, B. & Taleb-Ahmed, A. A. New construction of optical zero-correlation zone codes. J. Opt. Commun. 39, 359–368 (2018). https://doi.org/10.1515/joc-2017-0214
  14. Driz, S., Fassi, B., Mansour, M. A. & Taleb-Ahmed, A. FPGA implementation of a novel construction of optical zero-correlation zone codes for OCDMA systems. J. Opt. Commun. (2019). https://doi.org/10.1515/joc-2019-0048
  15. Kandouci, C., Djebbari, A. & Taleb-Ahmed, A. A new family of 2D-wavelength-time codes for OCDMA system with direct detection. Optik 135, 8–15 (2017). https://doi.org/10.1016/j.ijleo.2017.01.065
  16. Ahmed, H. Y., Zeghid, M., Imtiaz, W. A., Sharma, T. & Chehri, A. An efficient 2D encoding/decoding technique for optical communication system based on permutation vectors theory. Multimed. Syst. 27, 691–707 (2020). https://doi.org/10.1007/s00530-020-00711-3
  17. Imtiaz, W. A., Ahmed, H. Y., Zeghid, M. & Sharief, Y. Two dimensional optimized enhanced multi diagonal code for OCDMA passive optical networks. Opt. Quant. Electron. 52, 33 (2020). https://doi.org/10.1007/s11082-019-2145-9
  18. Jellali, N., Najjar, M., Ferchichi & M., Janyani, V. Performance enhancement of the 3D OCDMA system by using dynamic cyclic shift and multi-diagonal codes. Photonic Netw. Commun. 37, 63–74 (2019). https://doi.org/10.1007/s11107-018-0793-5
  19. Anuar, M. S., Aljunid, S. A., Saad, N. M. & Hamzah, S. M. New design of spectral amplitude coding in OCDMA with zero cross-correlation. Opt. Commun. 282, 2659–2664 (2009). https://doi.org/10.1016/j.optcom.2009.03.079
  20. Nisar, K. S., Sarangal, H. & Thapar, S. S. Performance evaluation of newly constructed NZCC for SAC-OCDMA using direct detection technique. Photonic Netw. Commun. 37, 75–82 (2019). https://doi.org/10.1007/s11107-018-0794-4
  21. Kaur, R. & Kaler, R. S. Performance of zero cross correlation resultant weight spectral amplitude codes in lower Earth orbit-based optical wireless channel system. Int. J. Commun. 33, e4456 (2020). https://doi.org/10.1002/dac.4456
  22. Nisar, K. S., Djebbari, A. & Kandouci, C. Development and performance analysis zero cross correlation code using a type of Pascal's triangle matrix for spectral amplitude coding optical code division multiple access networks. Optik. 159, 14–20 (2018). https://doi.org/10.1016/j.ijleo.2018.01.054
  23. Edwards, A. W. F. Pascal’s Arithmetical Triangle: The Story of a Mathematical Idea. (Johns Hopkins University Press, 2002).
  24. Németh, L. & Szalay, L. Power sums in hyperbolic Pascal triangles. Analele Universitatii “Ovidius" Constanta-Seria Matematica 26, 189–203 (2018). https://doi.org/10.2478/auom-2018-0012
  25. Kaur, S. & Singh, S. Review on developments in all-optical spectral amplitude coding techniques. Opt. Eng. 57, 116102 (2018). https://doi.org/10.1117/1.oe.57.11.116102
  26. Kumari, M., Sharma, R. & Sheetal, A. Performance analysis of high speed backward compatible TWDM-PON with hybrid WDM–OCDMA PON using different OCDMA codes. Opt. Quant. Electron. 52, 1–59 (2020). https://doi.org/10.1007/s11082-020-02597-x
  27. Zhao, H., Wu, D. & Fan, P. Constructions of optimal variable‐weight optical orthogonal codes. J. Comb. 18, 274–291 (2010). https://doi.org/10.1002/jcd.20246
  28. Kakaee, M. H., Seyedzadeh, S., Fadhil, H. A., Anas, S. B. A. & Mokhtar, M. Development of multi-service (MS) for SAC-OCDMA systems. Opt. Laser Technol. 60, 49–55(2014). https://doi.org/10.1016/j.optlastec.2014.01.002
  29. Kumawat, S. & Maddila, R. K. Development of ZCCC for multi-media service using SAC-OCDMA systems. Opt. Fiber Technol. 39, 12–20 (2017). https://doi.org/10.1016/j.yofte.2017.09.015
  30. Li, X. et al. Development and performance improvement of a novel zero cross-correlation code for SAC-OCDMA systems. J. Opt. Commun. 000010151520200086 (2020). https://doi.org/10.1515/joc-2020-0086
  31. Garadi, A., Djebbari, A. & Taleb-Ahmed, A. Exact analysis of signal-to-noise ratio for SAC-OCDMA system with direct detection, Optik 145, 89–94 (2017). http://doi.org/doi:10.1016/j.ijleo.2017.07.038
  32. Imtiaz, W. A., Ilyas, M. & Khan, Y. Performance optimization of spectral amplitude coding OCDMA system using new enhanced multi diagonal code. Infrared Phys. Technol. 79, 36–44 (2016). https://doi.org/10.1016/j.infrared.2016.09.006
  33. Rec, I. U. (1988). G. 707: Synchronous Digital Hierarchy - Bit Rates. International Telecommunication Union, ITU-T. (1988).
  34. Kartalopoulos, S. V. Communication Networks. in Next Generation Intelligent Optical Networks, from Access to Backbone. (Springer, Boston, MA, 2008). https://doi.org/10.1007/978-0-387-71756-2
  35. Calligaris Jr, A. O. & Silva, M.T.C. Multichannel Bandpass Optical Filter Integrated in Tandem For High-Speed Wavelength Division Multiplexed Systems. Revista Científica Periódica–Telecomunicações. 2, 28-29(1999). https://www.inatel.br/revista/downloads/marco-setembro-1999-s883750-1
  36. Naghar, A., Aghzout, O., Alejos, A. V., Sanchez, M. G. & Essaaidi, M. Design of compact wideband multi-band and ultra-wideband band pass filters based on coupled half wave resonators with reduced coupling gap. IET Microw. Antennas Propag. 9, 1786–1792 (2015). https://doi.org/10.1049/iet-map.2015.0188
  37. Adbulqader, S. G., Fadhil, H. A., Aljunid, S. A. & Safar, A. M. Performance Analysis of an OCDMA System Based on SPD Detection Utilizing Different Type of Optical Filters for Access Networks. in Advanced Computer and Communication Engineering Technology. (Cham Springer International Publishing, 2015). https://doi.org/10.1007/978-3-319-07674-4_31
Go to article

Authors and Affiliations

Samia Driz
1
Benattou Fassi
1
Chahinaz Kandouci
1
Fodil Ghali
1

  1. Telecommunications and Digital Signal Processing Laboratory, Djillali Liabes University, Sidi Bel Abbes, 22000 Algeria
Download PDF Download RIS Download Bibtex

Abstract

Underwater Acoustic Communications (UWAC) is an emerging technology in the field of underwater communications, and it is challenging because of the signal attenuation of the sound waves. Multiple Input and Multiple- Output (MIMO) is introduced in UWAC because of its support in enhancing the data throughput even under the conditions of interference, signal fading, and multipath. The paper presents the concept and analysis of 2× 2 MIMO UWAC systems that uses a 4- QAM spatial modulation scheme thus minimizing the decoding complexity and overcoming the Inter Channel Interference (IChI). Bit Error Rate (BER) investigation is carried out over different link distances under acoustic Line of Sight (LOS). The utilization of Zero Forcing (ZF) and Vertical-Bell Laboratories Layered Space-Time (VBLAST) equalizers, which estimates the transmitted data proves a success of removing Inter Symbol Interference (ISI). The ISI caused due to multipath effect and scattering in UWAC can be reduced by iterative process considered in VBLAST. A study is made on how the distance between the transmitter and the receiver and the Doppler Effect has its impact on the performance of the system.

Go to article

Authors and Affiliations

B. Pranitha
L. Anjaneyulu
Hoa Le Minh
Nauman Aslam
V. Sandeep Kumar
Download PDF Download RIS Download Bibtex

Abstract

Due to high performance demands of grid-connected pulse-width modulation (PWM) converters in power applications, backstepping control (BSC) has drawn wide research interest for its advantages, including high robustness against parametric variations and external disturbances. In order to guarantee these advantages while providing high static and dynamic responses, in this work, a robust BSC (RBSC) with consideration of grid-connected PWM converter parameter uncertainties is proposed for three-phase grid-connected four-leg voltage source rectifiers (GC-FLVSR). The proposed RBSC for GC-FLVSR is composed of four independent controllers based on the Lyabonov theory that control DC bus voltage and input currents simultaneously. As a result, unit power factor, stable DC-bus voltage, sinusoidal four-leg rectifier input currents with lower harmonics and zero-sequence (ZS), and natural currents can be accurately achieved. Furthermore, the stability and robustness against load, DC capacitor, and filter inductance variations can be tested. The effectiveness and superiority of the proposed RBSC compared to the PI control (PIC) have been validated by processor-inthe- loop (PIL) co-simulation using the STM32F407 discovery-development-board as an experimental study.
Go to article

Authors and Affiliations

Ali Chebabhi
1
Abdelhalim Kessal
2

  1. Electrical Engineering Laboratory (EEL), Faculty of Technology, University of M’sila, M’sila 28000, Algeria
  2. LPMRN Laboratory, Faculty of Sciences and Technology, University of Bordj Bou Arreridj, 34000, Algeria

This page uses 'cookies'. Learn more