Search results

Filters

  • Journals
  • Authors
  • Keywords
  • Date
  • Type

Search results

Number of results: 3
items per page: 25 50 75
Sort by:
Download PDF Download RIS Download Bibtex

Abstract

The paper is concerned with an analysis of behaviour of the cableway. On the basis of design data and results of adequate experiments, a physical model of cableway was formulated. The static of cableway was developed assuming a full nonlinear model based on elastic catenary curve. The tension of the rope and the reactive forces between the rope and the supports were calculated. Assuming various loadings of the rope, the relation between the tension in bottom and upper stations and the length of the rope was determined. The model describing the motion of the system is linear. Finite elements were used to formulate the model. Two methods of accelerating the system were investigated.

Go to article

Authors and Affiliations

Janusz Kowal
Jacek Snamina
Andrzej Podsiadło
Jarosław Konieczny
Download PDF Download RIS Download Bibtex

Abstract

Short-term contact losses between a pantograph and a contact wire are not included in the standards nor are they taken into account in evaluating pantograph-contact wire interaction. These contact losses, however, accelerate wear and tear as well as disturb operation of vehicles’ drive systems. The article presents the effects of short-term contact breaks as well as an analysis of impact of contact breakages on a vehicle’s current at 3 kV DC power supply. Results of voltage and current oscillations measured in real conditions when pantograph of a DC driven chopper vehicle was running under isolators were presented. Then a simulation model of a vehicles with ac motors and voltage inverters was derived to undertake simulation experiments verifying operation of such a vehicle in condition similar to those measured in real condition.

Go to article

Authors and Affiliations

T. Maciołek
M. Lewandowski
A. Szeląg
M. Steczek
Download PDF Download RIS Download Bibtex

Abstract

The study presents a calculation method of the voltage induced by power-line sagged conductor in an inductively coupled overhead circuit of arbitrary configuration isolated from ground. The method bases on the solution utilizing the magnetic vector potential for modeling 3D magnetic fields produced by sagging conductors of catenary electric power lines. It is assumed that the equation of the catenary exactly describes the line sag and the influence of currents induced in the earth on the distribution of power line magnetic field is neglected. The method derived is illustrated by exemplary calculations and the results obtained are partially compared with results computed by optional approach.

Go to article

Authors and Affiliations

Krzysztof Budnik
Wojciech Machczyński
Jan Szymenderski

This page uses 'cookies'. Learn more