Search results

Filters

  • Journals
  • Authors
  • Keywords
  • Date
  • Type

Search results

Number of results: 11
items per page: 25 50 75
Sort by:
Download PDF Download RIS Download Bibtex

Abstract

In the paper, the method of a numerical simulation concerning diagonal crack propagation in con-crete beams was presented. Two beams reinforced longitudinally but without shear reinforcement were considered during the Finite Element Method analysis. In particular, a nonlinear method was used to simulate the crack evaluation in the beams. The analysis was performed using the commercial program ANSYS. In the numerical simulation, the limit surface for concrete described by Willam and Warnke was applied to model the failure of concrete. To solve the FEM-system of equations, the Newton-Raphson method was used. As the results of FEM calculations, the trajectories of total stains and numerical images of smeared cracks were obtained for two analyzed beams: the slender beam S5 of leff = 1.8 m and the short beam S3k of leff = 1.1 m. The applied method allowed to generate both flexural vertical cracks and diagonal cracks in the shear regions. Some differences in the evaluation of crack patterns in the beams were observed. The greater number of flexural vertical cracks which penetrated deeper in the beam S5 caused the lower stiffness and the greater deformation in the beam S5 compared to the short beam S3k. Numerical results were compared with the experimental data from the early tests performed by Słowik [3]. The numerical simulation yielded very similar results as the experiments and it confirmed that the character of failure process altered according to the effective length of the member. The proposed numerical procedure was successfully verified and it can be suitable for numerical analyses of diagonal crack propagation in concrete beams.

Go to article

Authors and Affiliations

M. Słowik
P. Smarzewski
Download PDF Download RIS Download Bibtex

Abstract

The application of used glazed waste in concrete production can improve the performance of the structure of the building. Flexural and shear behavior and action of reinforced HollowGlass Concrete Beams (HGCB) and Solid Glass Concrete Beams (SGCB) made with glass waste under a two-point load are studied in this paper. In this work, 6 reinforced concrete solid and hollow beams were tested under a four-point bending test to evaluate and calculate the flexural behavior of SGCB and HGCB. For that purpose, Beams were prepared with 1000 mm length, 230 mm height, and 120 mm. All beams were divided into groups and named according to the space stirrups steel bar. The experimental work investigates five main variables which are: first: the comparison between SGCB and HGCB with the concrete beams made with glass waste (Glass Concrete Beam GCB), second: comparison between Solid Concrete Beams for Normal Concrete Beams (NCB), and GCB, three: comparison between Hollow Concrete Beams for NCB and GCB, four: the comparison between HGCB and HCB, last: the comparison between SGCB and SCB. The test results indicated that GCB was offered higher strength than NCB, but the load–slip behavior of all specimens is similar for both types of concretes, and the bond strength is not influenced by steel specimens. Furthermore, the results of this study indicated that the contribution of GCB to the load is indicated to be considerable. The results indicate that the hollow opening affected the ultimate load capacity and deflection of HGCB.
Go to article

Authors and Affiliations

Salam Salman Chiad Alharishawi
1
ORCID: ORCID
Nagham Rajaa
2
ORCID: ORCID
Aqeel Raheem Jabur
3
ORCID: ORCID

  1. Mustansiriyah University, College of Engineering, Environmental Engineering Department, Baghdad
  2. Mustansiriyah University, College of Engineering, Highway and Transportation Engineering Department, Baghdad, Iraq
  3. Mustansiriyah University, College of Engineering, Civil Engineering Department, Baghdad, Iraq
Download PDF Download RIS Download Bibtex

Abstract

“Polyurea coatings as a possible structural reinforcement system” is a research project aimed at exploring possible applications of polyurea coatings for improving structural performance (including steel, concrete, wooden and other structures used in the construction industry). As part of the project, this paper focuses on evaluating the performance of bent reinforced concrete (RC) beams covered with a polyurea coating system. Easy polyurea application and its numerous advantages can prove very useful when existing RC structural elements are repaired or retrofitted. Laboratory tests of three types of RC beams with three different longitudinal reinforcement ratios were performed for the purposes of this paper. The tests were designed to determine the bending strength, performance and cracking patterns of the coated RC beams. In addition, a theoretical model was developed to predict the impact of the polyurea coating on the bending strength of the RC beams. On this basis, the effect of the coating on the bending strength and the performance of the coated beams at the ultimate limit state (ULS) was examined and analyzed. The results showed that the use of the polyurea coating has a positive impact on the cracking state of the RC beams subject to bending and little effect on their bending strength.
Go to article

Authors and Affiliations

Jacek Szafran
1
ORCID: ORCID
Artur Matusiak
1
Katarzyna Rzeszut
2
ORCID: ORCID
Iwona Jankowiak
3

  1. Department of Structural Mechanics, Faculty of Civil Engineering, Architecture and Environmental Engineering, Lodz University of Technology, Aleja Politechniki 6, 90-924 Łódź, Poland
  2. Institute of Building Engineering, Faculty of Civil and Transport Engineering, Poznan University of Technology, Piotrowo 5, 60-965 Poznan, Poland
  3. Institute of Civil Engineering, Faculty of Civil and Transport Engineering, Poznan University of Technology, Piotrowo 5, 60-965 Poznan, Poland
Download PDF Download RIS Download Bibtex

Abstract

The aim of this paper is a comparative analysis of the experimental test results of twenty T-section beams reinforced with glass fiber reinforced polymer (GFRP) bars without stirrups with predicted values of the shear capacity according to the following design guidelines: draft Eurocode 2, Japanese JSCE, American ACI 440, Italian CNR- DT-203/2006, British BS according to fib Bulletin 40, Canadian CSA-S806-12 and ISIS-M03-07. Standard procedures for FRP reinforced beams based on traditional steel reinforced concrete guidelines. The longitudinal FRP reinforcement has been taken into account by its stiffness reduction related to the steel reinforcement. A basis of this modification is the assumption that the FRP-to-concrete bond behaviour is the same as it is for steel reinforcement. To assess the compatibility of predicted values (Vcal) with the experimental shear forces (Vtest) the safety coefficient η = Vtest / Vcal was used. The results corresponding to values η < 1 indicates overestimation of the shear capacity, but η > 1 means that shear load capacity is underestimated. The most conservative results of the calculated shear capacity are obtained from the ACI 440 standard. In contrast to them the best compatibility of the calculated shear values to the experimental ones indicated British BS standard, fib Bulletin 40 and Canadian CSA-S806-12 standard.

Go to article

Authors and Affiliations

Monika Kaszubska
ORCID: ORCID
Renata Kotynia
Download PDF Download RIS Download Bibtex

Abstract

The paper presents results of experimental tests carried out on concrete beams reinforced with glass fibre polymer reinforced (GFRP) bars, which have become recently one of the main substitutes for traditional steel reinforcement. GFRP bars were used in this research as the longitudinal and transverse reinforcement. An objective of the study was to investigate the influence of the shear reinforcement ratio on the shear capacity of GFRP reinforced concrete beams in comparison with the corresponding beam without shear reinforcement. Single-span, simply-supported T-section beams reinforced in flexure with 5 GFRP bars of 25 mm diameter were reinforced in shear with closed GFRP stirrups of 8 mm diameter applied in three variable spacings: 250 mm, 200 mm and 120 mm. The analysis of test results, failure modes and shear capacity is discussed in the paper in respect to investigated parameters.
Go to article

Authors and Affiliations

Damian Szczech
1
Renata Kotynia
1

  1. Lodz University of Technology, Faculty of Civil Engineering, Architecture and Environmental Engineering, al. Politechniki 6, 90-924 Łódź, Poland
Download PDF Download RIS Download Bibtex

Abstract

This paper presents probabilistic assessment of load-bearing capacity and reliability for different STM of beams loaded with a torsional and bending moment. Three beams having different reinforcement arrangement obtained on the basis of STM but the same overall geometry and loading pattern were analysed. Stochastic modelling of this beams were performed in order to assess probabilistic load-bearing capacity. In the analysis, the random character of input data - concrete and steel was assumed. During the randomization of variables the Monte Carlo simulation with the reduce the number of simulations the Latin Hypercube Sampling (LHS) method was applied. The use of simulation methods allows for approximation of implicit response functions for complex in description and non-linear reinforced concrete structures. On the basis of the analyses and examples presented in the paper, it has been shown that the adoption of different ST models determines the different reliability of the analysed systems and elements.

Go to article

Authors and Affiliations

Lidia Buda-Ożóg
ORCID: ORCID
Katarzyna Sieńkowska
ORCID: ORCID
Izabela Skrzypczak
ORCID: ORCID
Download PDF Download RIS Download Bibtex

Abstract

The scope of the paper is to investigate analytically and determine experimentally the shear resistance of low height reinforced precast concrete lintels. The chosen procedures included in national and international standards applied for the design of structural concrete elements to an estimation of shear behaviour of reinforced concrete elements are described. The characteristic and designed shear strength of precast concrete lintels are determined and compared with experimentally obtained results. The shear resistance for precast concrete lintels was determined by laboratory tests according to a European standard. The assessment of the in-situ compressive strength of concrete in precast concrete lintel is specified. The designed compressive strength class is confirmed. The real reinforcement distribution is verified to assess the wide scatter of experimentally obtained failure forces. A short literature outlook of the papers concerning investigations on lintels and shear resistance of concrete is given also. The paper can provide scientists, engineers, and designers a theoretical and experimental basis in the field of precast concrete lintels shear resistance.

Go to article

Authors and Affiliations

Andrzej Ambroziak
ORCID: ORCID
Jarosław Kondrat
Marek Wesołowski
Download PDF Download RIS Download Bibtex

Abstract

Damage occurring on a reinforced concrete beam (e.g. spalling) can reduce beam’s capacity to withstand external loads. The damage becomes more critical if it is occurred in the shear span since it may lead to shear failure. Patching to the damage zone by suitable patch repair material could be the best option in restoring the shear capacity of the beam. This research investigates the shear recovery of patched reinforced concrete beams with web reinforcement. The patching material used is unsaturated polyester resin mortar. The shear recovery is assessed on the basis of the patched beam’s behavior under flexure-shear load in comparison with those of normal beams. The behavior observed include cracking failure mode, strains of the reinforcements, and load-deflection behavior. The results indicate that the UPR mortar is capable to restore the strength of the damage reinforced concrete beam. The characteristic of UPR mortar (low elastic modulus and high strength) can be the origin of the overall behavior of the patched reinforced concrete beams.
Go to article

Authors and Affiliations

Stefanus Adi Kristiawan
1
ORCID: ORCID
Agus Supriyadi
1
ORCID: ORCID
Halwan Alfisa Saifullah
1
ORCID: ORCID

  1. University of Sebelas Maret, Civil Engineering Department, SMART Crete Research Group, Jl. Ir.Sutami No. 36A Surakarta 57126, Indonesia
Download PDF Download RIS Download Bibtex

Abstract

The paper presents the method of simplified parametric analysis of the sensitivity of a pre-tensioned concrete beam. The presented approach is based on the DOE (design of experiments) data collection which is simulation technique allowing for identification of variables deciding about the effectiveness and costs of designed structures. Additionally, application of the hyper-surface of the construction response allows designers to the development of multi-dimensional trade-off graphs to facilitate, the assessment of the scope of changes in random state variables permitted due to the adequate criteria and selection of their values close to optimum. Design basics, procedures and results of the presented considerations of sensitivity assessment and reliability of the structure has been shown on the example of a pre-stressed concrete beam designed in accordance with the requirements and procedures of Eurocode 2.

Go to article

Authors and Affiliations

Sz. Woliński
T. Pytlowany
Download PDF Download RIS Download Bibtex

Abstract

In this paper, based on the feasible method and sensors for the full-scale prestressed monitor, the novel optical fiber sensors and the traditional monitoring sensors will be set up into two prestressed concrete beams with the same geometrical dimensions, material properties, and construction conditions, etc. to investigate the working state of the novel sensors and obtain the evolution law of prestress loss of the prestressed feature component under the static load. The results show that the evolution law of prestress loss of the loaded beam under the condition of no damage state and initial crack is the same as the non-loaded one; however, the prestress loss increases with the increase of time under the situation with the limit crack. The total loss of the prestressed beam with the limit crack is 36.4% without damage. The prestress loss of the prestressed beam under the static load increase with the development of the crack (injury).
Go to article

Authors and Affiliations

Jinbo Wang
1
ORCID: ORCID
Guodong Li
1
ORCID: ORCID
Chunguang Lan
2
ORCID: ORCID
Nan Guo
1
ORCID: ORCID

  1. Northeast Forestry University, School of Civil Engineering, Al. Harbin City, Heilongjiang Province, China
  2. Beijing Building Construction Research Institute Co., Ltd, A1. Beijing, China
Download PDF Download RIS Download Bibtex

Abstract

Early detection of damage is necessary for the safe and reliable use of civil engineering structures made of concrete. Recently, the identification of micro-cracks in concrete has become an area of growing interest, especially when it comes to using wave-based techniques. In this paper, a non-destructive testing approach for the characterization of the fracture process was presented. Experimental tests were performed on concrete beams subjected to mechanical degradation in a 3-point bending test. Ultrasonic waves were registered on a specimen surface by piezoelectric transducers located at several points. Then, the signals were processed taking advantage of wave scattering due to micro-crack disturbances. For early-stage damage detection, coda wave interferometry was used. The novelty of the work concerns the application of the complex decorrelation matrix and the moving reference trace approach for better distinguishment of sensors located in different parts of a crack zone. To enhance coda wave-based damage identification results, optical imaging of crack development was performed by means of digital image correlation measurement. The results obtained showed that the coda wave interferometry technique can be successfully used as a quantitative measure of changes in the structure of concrete. The results also indicated that the course of decorrelation coefficient curves enabled the identification of three stages during degradation, and it depended on the location of acquisition points versus the crack zone.
Go to article

Authors and Affiliations

Magdalena Knak
1
ORCID: ORCID
Erwin Wojtczak
1
ORCID: ORCID
Magdalena Rucka
1
ORCID: ORCID

  1. Department of Mechanics of Materials and Structures, Faculty of Civil and Environmental Engineering, Gdańsk University of Technology,Narutowicza 11/12, 80-233, Gdańsk, Poland

This page uses 'cookies'. Learn more