Search results

Number of results: 8
items per page: 25 50 75
Sort by:
Download PDF Download RIS Download Bibtex

Abstract

This paper describes a fault-tolerant controller (FTC) of induction motor (IM) with inter-turn short circuit in stator phase winding. The fault-tolerant controller is based on the indirect rotor field oriented control (IRFOC) and an observer to estimate the motor states, the amount of turns involved in short circuit and the current in the short circuit. The proposed fault controller switches between the control of the two components of measured stator current in the synchronously rotating reference frame and the control of the two components of estimated current in the case of faulty condition when the estimated current in the short circuit is not destructive of motor winding. This technique is used to eliminate the speed and the rotor flux harmonics and to assure the decoupling between the rotor flux and torque controls. The results of the simulation for controlling the speed and rotor flux of the IM demonstrate the applicability of the proposed FTC.

Go to article

Authors and Affiliations

Djilali Toumi
Mohamed Boucherit
Mohamed Tadjine
Download PDF Download RIS Download Bibtex

Abstract

The paper presents a solution for sensorless field oriented control (FOC) system for five-phase induction motors with improved rotor flux pattern. In order to obtain the advantages of a third harmonic injection with a quasi-trapezoidal flux shape, two vector models, α1–β1 and α3–β3, were transformed into d1–q1, d3–q3 rotating frames, which correlate to the 1st and 3rd harmonic plane respectively. A linearization approach of the dual machine model in dq coordinate frames is proposed by introducing a new additional variable “x” which is proportional to the electromagnetic torque. By applying the static feedback control law, a dual mathematical model of the five-phase induction motor was linearized to synthesize a control system in which the electromagnetic torque and the rotor flux can be independently controlled. The results shows the air gap flux shape in steady as well transient states under various load conditions. Moreover, the implemented control structure acquires fault tolerant properties and leads to possible emergency running with limited operation capabilities. The fault-tolerant capability of the analyzed machine was guaranteed by a special implemented control system with a dedicated speed observer, which is insensitive to open-phase fault situation. The experimental tests have been performed with single and double-open stator phase fault. A torque measurement was implemented to present the mechanical characteristics under healthy and faulty conditions of the drive system.

Go to article

Authors and Affiliations

F. Wilczyński
P. Strankowski
J. Guziński
M. Morawiec
A. Lewicki
Download PDF Download RIS Download Bibtex

Abstract

Wind energy has achieved prominence in renewable energy production. There fore, it is necessary to develop a diagnosis system and fault-tolerant control to protect the system and to prevent unscheduled shutdowns. The presented study aims to provide an experimental analysis of a speed sensor fault by hybrid active fault-tolerant control (AFTC) for a wind energy conversion system (WECS) based on a permanent magnet synchronous generator (PMSG). The hybrid AFTC switches between a traditional controller based on proportional integral (PI) controllers under normal conditions and a robust backstepping controller system without a speed sensor to avoid any deterioration caused by the sensor fault. A sliding mode observer is used to estimate the PMSG rotor position. The proposed controller architecture can be designed for performance and robustness separately. Finally, the proposed methodwas successfully tested in an experimental set up using a dSPACE 1104 platform. In this experimental system, the wind turbine with a generator connection via a mechanical gear is emulated by a PMSM engine with controled speed through a voltage inverter. The obtained experimental results show clearly that the proposed method is able to guarantee service production continuity for the WECS in adequate transition.

Go to article

Authors and Affiliations

Ahmed Tahri
Said Hassaine
Sandrine Moreau
Download PDF Download RIS Download Bibtex

Abstract

This paper presents a fault-tolerant control scheme for a 2 DOF helicopter. The 2 DOF helicopter is a higher-order multi-input multi-output system featuring non-linearity, cross-coupling, and unstable behaviour. The impact of sensor, actuator, and component faults on such highly complex systems is enormous. This work employs sliding mode control, which is based on reaching and super-twisting laws, to handle the problem of fault control. Simulation tests are carried out to show the effectiveness of the algorithms. Various performance metrics are analyzed and the results show SMC based on super-twisting law provides better control with less chattering. The stability of the closed-loop system is mathematically assured, in the presence of faults, which is a key contribution of this research.
Go to article

Authors and Affiliations

M. Raghappriya
1
S. Kanthalakshmi
2

  1. Department of Electronics and Instrumentation Engineering, Government College of Technology, Coimbatore, India
  2. Department of Electrical and Electronics Engineering, PSG College of Technology, Coimbatore, India
Download PDF Download RIS Download Bibtex

Abstract

Three-level T-type inverters have lower total harmonic distortion in output voltage, higher power density and lower voltage stress of power switches compared with conventional two-level inverters and have been widely used in applications with a wide-power range. Reliability improvement is particularly important for the T-type inverters because of the increased number of power switches and high system complexity. This paper proposes a fault-tolerant topology, which is constructed by adding a redundant leg including halfbridge switches and neutral-point switches connected between the DC bus capacitors and the DC-link midpoint of the conventional T-type inverter. In addition, an after-fault control strategy is proposed based on the results of a fault diagnosis method using bridge voltage. The fault-tolerant control of the open-circuit fault of the power switches and the phase-leg fault can both be achieved by the proposed method. Experimental results are given to verify that the proposed fault-tolerant three-level T-type inverter can output the full voltage level and power during the fault-tolerant operation based on the proposed control strategy.
Go to article

Authors and Affiliations

Danjiang Chen
1
ORCID: ORCID
Liyuan Zheng
1
ORCID: ORCID

  1. College of Information and Intelligence Engineering, Zhejiang Wanli University, No. 8, South Qian Hu Road, Ningbo, Zhejiang, China 315100
Download PDF Download RIS Download Bibtex

Abstract

The iterative learning fault-tolerant control strategies with non-strict repetitive initial state disturbances are studied for the linear discrete networked control systems (NCSs) and the nonlinear discrete NCSs. In order to reduce the influence of the initial state disturbance in iteration, for the linear NCSs, considering the external disturbance and actuator failure, the iterative learning fault-tolerant control strategy with impulse function is proposed. For the nonlinear NCSs, the external disturbance, packet loss and actuator failure are considered, the iterative learning fault-tolerant control strategy with random Bernoulli sequence is provided. Finally, the proposed control strategies are used for simulation research for the linear NCSs and the nonlinear NCSs. The results show that both strategies can reduce the influence of the initial state disturbance on the tracking effect, which verifies the effectiveness of the given method.
Go to article

Authors and Affiliations

Fu Xingjian
1
Zhao Qianjun
1

  1. School of Automation, Beijing Information Science and Technology University, Beijing 100192, China
Download PDF Download RIS Download Bibtex

Abstract

Modern induction motor (IM) drives with a higher degree of safety should be equipped with fault-tolerant control (FTC) solutions. Current sensor (CS) failures constitute a serious problem in systems using vector control strategies for IMs because these methods require state variable reconstruction, which is usually based on the IM mathematical model and stator current measurement. This article presents an analysis of the operation of the direct torque control (DTC) for IM drive with stator current reconstruction after CSs damage. These reconstructed currents are used for the stator flux and electromagnetic torque estimation in the DTC with space-vector-modulation (SVM) drive. In this research complete damage to both stator CSs is assumed, and the stator current vector components in the postfault mode are reconstructed based on the DC link voltage of the voltage source inverter (VSI) and angular rotor speed measurements using the so-called virtual current sensor (VCS), based on the IM mathematical model. Numerous simulation and experimental tests results illustrate the behavior of the drive system in different operating conditions. The correctness of the stator current reconstruction is also analyzed taking into account motor parameter uncertainties, especially stator and rotor resistances, which usually are the main parameters that determine the proper operation of the stator flux and torque estimation in the DTC control structure.
Go to article

Authors and Affiliations

Michal Adamczyk
1
ORCID: ORCID
Teresa Orlowska-Kowalska
1
ORCID: ORCID

  1. Department of Electrical Machines, Drives and Measurements, Wroclaw University of Science and Technology, ul. Wybrzeze Wyspianskiego 27, 50-370 Wroclaw, Poland
Download PDF Download RIS Download Bibtex

Abstract

The paper presents the analysis of different fault states in drive systems with multiphase induction motors. The mathematical models of a five-phase and six-phase induction motor and the MRASCC estimator have been presented and the description of the Space Vector Modulation has been shown. The Direct Field-Oriented Control (DFOC) system is analyzed. Results of the simulation and experimental studies of the Direct Field-Oriented Control systems in the fault conditions are presented. The author’s original contribution includes analysis and studies of the DFOC control method of a five-phase induction motor resistant to the motor speed sensor fault with the use of the MRASCC estimator.

Go to article

Authors and Affiliations

Jacek Jan Listwan