Search results

Filters

  • Journals
  • Authors
  • Keywords
  • Date
  • Type

Search results

Number of results: 8
items per page: 25 50 75
Sort by:
Download PDF Download RIS Download Bibtex

Abstract

Detailed studies have suggested that the critical heat flux in the form of dryout in minichannels occurs when the combined effects of entrainment, deposition, and evaporation of the film make the film flow rate go gradually and smoothly to zero. Most approaches so far used the mass balance equation for the liquid film with appropriate formulations for the rate of deposition and entrainment respectively. It must be acknowledged that any discrepancy in determination of deposition and entrainment rates, together with cross-correlations between them, leads to the loss of accuracy of model predictions. Conservation equations relating the primary parameters are established for the liquid film and vapor core. The model consists of three mass balance equations, for liquid in the film as well as two-phase core and the gas phase itself. These equations are supplemented by the corresponding momentum equations for liquid in the film and the two-phase core. Applicability of the model has been tested on some experimental data.

Go to article

Authors and Affiliations

Dariusz Mikielewicz
Jan Wajs
Download PDF Download RIS Download Bibtex

Abstract

In the paper presented is the analysis of the results of calculations using a model to predict flow boiling of refrigerants such as R134a, R600a and R290. The latter two fluids were not used in the development of the model semiempirical correction. For that reason the model was verified with present experimental data. The experimental research was conducted for a full range of quality variation and a relatively wide range of mass velocity. The aim of the present study was also to test the sensitivity of developed model to a selection of the model of two-phase flow multiplier and the nonadiabatic effects. For that purpose two models have been analysed namely the one due to Müller-Steinhagen and Heck, and Friedel. In addition, the work shows the importance of taking surface tension into account in the calculation of the flow structure.
Go to article

Authors and Affiliations

Dariusz Mikielewicz
Blanka Jakubowska
Download PDF Download RIS Download Bibtex

Abstract

In the paper the experimental analysis of dryout in small diameter channels is presented. The investigations were carried out in vertical pipes of internal diameter equal to 1.15 mm and 2.3 mm. Low-boiling point fluids such as SES36 and R123 were examined. The modern experimental techniques were applied to record liquid film dryout on the wall, among the others the infrared camera. On the basis of experimental data an empirical correlation for predictions of critical heat flux was proposed. It shows a good agreement with experimental data within the error band of 30%. Additionally, a unique approach to liquid film dryout modeling in annular flow was presented. It led to the development of the three-equation model based on consideration of liquid mass balance in the film, a two-phase mixture in the core and gas. The results of experimental validation of the model exhibit improvement in comparison to other models from literature.

Go to article

Authors and Affiliations

Jan Wajs
Dariusz Mikielewicz
Michał Gliński
ORCID: ORCID
Download PDF Download RIS Download Bibtex

Abstract

The paper presents experimental studies on boiling heat transfer in rectangular minichannels. The investigations focus on the transition from single phase forced convection to nucleate boiling, i.e., in the zone of boiling incipience. The experiment has been carried out with FC-72, R-123 and R-11 at the Reynolds number below 4700, corresponding to mass flow rate range 95-710 kg/(m s). The main part of the test section is a minichannel of pre-set depth from 0.7 to 2 mm and width (20, 40 and 60 mm), with different spatial orientations from vertical to horizontal and 30% inclination angle adjustment. The objective of the paper includes the impact of selected parameters (liquid flow velocity, pressure and inlet liquid subcooling, channel dimensions and spatial orientation) on the boiling incipience in minichannels. The investigations are intended to develop a correlation for the calculations of the Nusselt number under the conditions of boiling incipience in the minichannel as a function of changeable parameters.
Go to article

Authors and Affiliations

Magdalena Piasecka
Download PDF Download RIS Download Bibtex

Abstract

In the paper presented are the results of calculations using authors own model to predict heat transfer coefficient during flow boiling of carbon dioxide. The experimental data from various researches were collected. Calculations were conducted for a full range of quality variation and a wide range of mass velocity. The aim of the study was to test the sensitivity of the in-house model. The results show the importance of taking into account the surface tension as the parameter exhibiting its importance in case of the flow in minichannels as well as the influence of reduced pressure. The calculations were accomplished to test the sensitivity of the heat transfer model with respect to selection of the appropriate two-phase flow multiplier, which is one of the elements of the heat transfer model. For that purpose correlations due to Müller-Steinhagen and Heck as well as the one due to Friedel were considered. Obtained results show a good consistency with experimental results, however the selection of two-phase flow multiplier does not significantly influence the consistency of calculations.

Go to article

Authors and Affiliations

Dariusz Mikielewicz
Blanka Jakubowska
Download PDF Download RIS Download Bibtex

Abstract

Miniature heat exchangers are used to provide higher cooling capacity for new technologies. This means a reduction in their size and cost but the identical power. The paper presents the method for determination of boiling heat transfer coefficient for a rectangular minichannel of 0.1 mm depth, 40 mm width and 360 mm length with asymmetric heating. Experimental research has focused on the transition from single phase forced convection to nucleate boiling, i.e., the zone of boiling incipience. The ‘boiling front’ location has been determined from the temperature distribution of the heated wall obtained from liquid crystal thermography. The experiment has been carried out with R-123, mass flux 220 kg/(m2s), pressure at the channel inlet 340 kPa. Local values of heat transfer coefficient were calculated on the basis of empirical data from the experiment following the solution of the two-dimensional inverse heat transfer problem. This problem has been solved with the use of the finite element method in combination with Trefftz functions. Temperature approximates (linear combinations of Trefftz functions) strictly fulfill the governing equations. In presented method the inverse problem is solved in the same way as the direct problem. The results confirmed that considerable heat transfer enhancement takes place at boiling incipience in the minichannel flow boiling. Moreover, under subcooling boiling, local heat coefficients exhibit relatively low values.

Go to article

Authors and Affiliations

Magdalena Piasecka
Beata Maciejewska
Download PDF Download RIS Download Bibtex

Abstract

In the present research, an experimental investigation was conducted to assess the heat transfer coefficient of aqueous citric acid mixtures. The experimental facility provides conditions to assess the influence of various operating conditions such as the heat flux (0–190 kW/m2), mass flux (353–1059 kg/m2s) and the concentration of citric acid in water (10%– 50% by volume) with a view to measure the subcooled flow boiling heat transfer coefficient of the mixture. The results showed that two main heat transfer mechanisms can be identified including the forced convective and nucleate boiling heat transfer. The onset point of nucleate boiling was also identified, which separates the forced convective heat transfer domain from the nucleate boiling region. The heat transfer coefficient was found to be higher in the nucleate boiling regime due to the presence of bubbles and their interaction. Also, the influence of heat flux on the heat transfer coefficient was more pronounced in the nucleate boiling heat transfer domain, which was also attributed to the increase in bubble size and rate of bubble formation. The obtained results were also compared with those theoretically obtained using the Chen type model and with some experimental data reported in the literature. Results were within a fair agreement of 22% against the Chen model and within 15% against the experimental data.

Go to article

Authors and Affiliations

Mohammad Amin Abdolhossein Zadeh
Shima Nakhjavani
Download PDF Download RIS Download Bibtex

Abstract

In this work we investigate the present capabilities of computational fluid dynamics for wall boiling. The computational model used combines the Euler/Euler two-phase flow description with heat flux partitioning. This kind of modeling was previously applied to boiling water under high pressure conditions relevant to nuclear power systems. Similar conditions in terms of the relevant non-dimensional numbers have been realized in the DEBORA tests using dichlorodifluoromethane (R12) as the working fluid. This facilitated measurements of radial profiles for gas volume fraction, gas velocity, bubble size and liquid temperature as well as axial profiles of wall temperature. After reviewing the theoretical and experimental basis of correlations used in the ANSYS CFX model used for the calculations, we give a careful assessment of the necessary recalibrations to describe the DEBORA tests. The basic CFX model is validated by a detailed comparison to the experimental data for two selected test cases. Simulations with a single set of calibrated parameters are found to give reasonable quantitative agreement with the data for several tests within a certain range of conditions and reproduce the observed tendencies correctly. Several model refinements are then presented each of which is designed to improve one of the remaining deviations between simulation and measurements. Specifically we consider a homogeneous MUSIG model for the bubble size, modified bubble forces, a wall function for turbulent boiling flow and a partial slip boundary condition for the liquid phase. Finally, needs for further model developments are identified and promising directions discussed.
Go to article

Authors and Affiliations

Roland Rzehak