Search results

Filters

  • Journals
  • Authors
  • Keywords
  • Date
  • Type

Search results

Number of results: 4
items per page: 25 50 75
Sort by:
Download PDF Download RIS Download Bibtex

Abstract

The issue of air pollution, resulting to a large extent from the use of fossil fuels for energy purposes, is one of the most serious environmental threats in several Polish cities, but also outside of them. The amount of pollutants emitted into the atmosphere translates into the living conditions of the inhabitants. The utilization of geothermal energy, which is a renewable and ecological source of energy, brings noticeable improvement in the quality of atmospheric air, as evidenced by significant ecological effects achieved by working geothermal district heating plants. The paper presents results of comprehensive considerations focused on assessing the effects of utilization of geothermal water and energy in Poland. Issues related to the implementation of exploration works aimed at acquiring geothermal water resources, as well as environmental aspects of the use of geothermal waters and energy were discussed. The undertaken considerations have been directed at assessing whether the use of such a kind of renewable energy resources could have an impact on improving the living conditions of the local community.

Go to article

Authors and Affiliations

Anna Sowiżdżał
Anna Chmielowska
Barbara Tomaszewska
Agnieszka Operacz
Józef Chowaniec
Download PDF Download RIS Download Bibtex

Abstract

Geothermal energy is renewable and clean. Moreover, new geothermal technology offers the added environmental benefit of geological storage of CO2.
Go to article

Authors and Affiliations

Anna Sowiżdżał
1

  1. AGH University of Science and Technology in Kraków, Poland
Download PDF Download RIS Download Bibtex

Abstract

The paper presents precipitation results from cold thermal water deposits that are the main cause of clogging in absorbent geothermal wells and borehole areas. As a result of physical and chemical analysis, laboratory tests and observation of the operation of a geothermal installation, a new method was developed to prevent the precipitation of sludge from cooled thermal water. The method being a modification of soft acidising was tentatively named as a super soft acidising method

Go to article

Authors and Affiliations

Bogdan Noga
Jan Marjanowski
Henryk Biernat
Stanisław Kulik
Bogusław Zieliński
Arkadiusz Nalikowski
Download PDF Download RIS Download Bibtex

Abstract

This paper presents the experimental investigation of an earthto- air heat exchanger for heating purposes in the Patna region of India, using an experimental test rig. In the view of the author, real field experiments have several limitations such as lack of repeatability and uncontrolled conditions. It also takes more time for the response of parameters that depends on nature and climate. Moreover, earth-to-air heat exchangers may be expensive to fabricate and require more land area. Thus, in this work authors executed their experimental work in indoor controllable environments to investigate the thermal performance of an earth-to-air heat exchanger. The actual soil conditions were created and maintained the temperature at 26˚C throughout the soil in the vicinity of pipes. Three horizontal PVC pipes of equal lengths and diameters of 0.0285 m, 0.038 m and 0.0485 m were installed in the test rig. The experiments were performed for different inlet air velocities at ambient air temperature. This study acknowledges that the maximum rise in outlet temperature occurs at a lower speed for smaller pipes. Also, the maximum effectiveness of 0.83 was observed at 2 m/s for the smallest diameter pipe.
Go to article

Bibliography

[1] Uddin M.S., Ahmed R., Rahman M.: Performance evaluation and life cycle analysis of earth to air heat exchanger in a developing country. Energy Build. 128(2016), 254–261.
[2] Yusof T.M., Anuar S., Ibrahim H.: A review of ground heat exchangers for cooling application in the Malaysian climate. J. Mech. Eng. Sci. 8(2015), 1426–1439.
[3] Bisoniya T.S., Kumar A., Baredar P.: Heating potential evaluation of earth-air heat exchanger system for winter season. J. Build. Phys. 39(2015), 3, 242–260.
[4] Sehli A., Hasni A., Tamali M.: The potential of earth-air heat exchangers for low energy cooling of buildings in South Algeria. Energy Proced. 18(2012), 496–506.
[5] D’Agostino D., Marino C., Minichiello F.: Earth-to-air versus air-to-air heat exchangers: A numerical study on the energetic, economic, and environmental performances for Italian office buildings. Heat Transf. Eng. 41(2020), 12, 1040–1051.
[6] Benrachi N., Ouzzane M., Smaili A., Lamarche L., Badache M., Maref W.: Numerical parametric study of a new earth-air heat exchanger configuration designed for hot and arid climates. Int. J. Green Energy 17(2020), 2, 115–126.
[7] Abbaspour-Fard M.H., Gholami A., Khojastehpour M.: Evaluation of an earth-to-air heat exchanger for the north-east of Iran with semi-arid climate. Int. J. Green Energy 8(2011), 4, 499–510.
[8] Lin J., Nowamooz H., Braymand S.,Wolff P., Fond C.: Impact of soil moisture on the long-term energy performance of an earth-air heat exchanger system. Renew. Energy 147(2018), 2, 2676–2687.
[9] Agrawal K.K., Yadav T., Misra R., Agrawal G.D.: Effect of soil moisture contents on thermal performance of earth-air-pipe heat exchanger for winter heating in arid climate: In situ measurement. Geothermics 77 (2019), 12–23
[10] Abu-Hamdeh N.H.: Thermal properties of soils as affected by density and water content. Biosyst. Eng. 86(2003), 1, 97–102.
[11] Balghouthi M., Kooli S., Farhat A., Daghari H., Belghith A.: Experimental investigation of thermal and moisture behaviors of wet and dry soils with buried capillary heating system. Sol. Energy 79(2005), 6, 669–681.
[12] Mihalakakou G., Santamouris M., Asimakopoulos D.: Use of the ground for heat dissipation. Energy. 19(1994), 17–25.
[13] Gan G.: Simulation of dynamic interactions of the earth–air heat exchanger with soil and atmosphere for preheating of ventilation air. Appl. Energy 158(2015), 118–132.
[14] Abu-Hamdeh N.H., Reederb R.C.: Soil thermal conductivity effects of density, moisture, salt concentration, and organic matter. Soil Sci. Soc. Am. J. 64(2000), 1285–1290.
[15] Mei V.C.: Effect of backfilling material on ground coil performance. In: Proc. Ann. meeting of the ASHRAE, Nashville, 28 Jun, 1987, Oak Ridge Nat. Lab. 1987.
[16] Shojaee S.M.N., Malek K.: Earth-to-air heat exchangers cooling evaluation for different climates of Iran. Sustain. Energy Technol. Assess. 23(2017), 111–120.
[17] Mathur A., Srivastava A., Agrawal G.D., Mathur S., Mathur J.: CFD analysis of EATHE system under transient conditions for intermittent operation. Energy Build. 87(2015), 37–44.
[18] Serageldin A.A., Abdelrahman A.K., Ookawara S.: Earth-air heat exchanger thermal performance in Egyptian conditions: experimental results, mathematical model, and computational fluid dynamics simulation. Energy Convers. Manage. 122(2016), 25–38.
[19] Ahmad Sn., Prakash O.: Optimization of earth air tube heat exchanger for cooling application using Taguchi technique. Int. J. Heat Technol. 38(2020), 4, 854–862.
[20] Vargas J.V.C., Ordonez. J.C., Zamfirescu C., Campos M.C., Bejan A.: Optimal ground tube length for cooling of electronics shelters. Heat Transf. Eng. 26(2005), 10, 8–20.
[21] Ahmad S.N., Prakash O.: Optimization of ground heat exchanger of the ground source heat pump system based on exergetic analysis using Taguchi technique. Proc. Inst. Mech. Eng. C. J. Mech. Eng. Sci. 235(2021), 21, 5892–5901.
[22] Gao J., Li A., Xu X., Gang W., Yan T.: Ground heat exchangers: Applications, technology integration and potentials for zero energy buildings. Renew. Energy 128(2018), 337–349.
[23] Ahmad S.N., Prakash O.: A review on pre-installing investigations of earth air tube heat exchanger (EATHE). In Advances in Industrial Automation and Smart Manufacturing (A. Arockiarajan, M. Duraiselvam, Ramesh Raju, Eds.). Springer, Singapore 2020, 225–232.
[24] Yassine B., Ghali K., Ghaddar N., Chehab G., Srour I.: Effectiveness of the earth tube heat exchanger system coupled to a space model in achieving thermal comfort in rural areas. Int. J. Sustain. Energy 33(2014), 3, 567–586.
[25] Qi D., Li S., Zhao C., Xie W., Li A.: Structural optimization of multi-pipe earth to air heat exchanger in greenhouse. Geothermics 98(2022), 102288.
[26] Amanowicz A.: Influence of geometrical parameters on the flow characterictics of multi-pipe earth-to-air heat exchangers- experimental and CFD investigations. Appl. Energy 226(2018), 849–861.
[27] Amanowicz L., Wojtkowiak J.: Comparison of single- and multipipe earth-to-air heat exchangers in terms of energy gains and electricity consumption: A case study for the temperate climate of central europe. Energies 14(2021), 8217, 1–28.
[28] Hasan M.I., Noori S.W., Shkarah A.J.: Parametric study on the performance of the earth to air heat exchanger for cooling and heating applications. Heat Transf. – Asian Res. 48(2019), 4, 1805–1829.
[29] Wu H., Wang S., Zhu D.: Modelling and evaluation of cooling capacity of earthair- pipe systems. Energy Convers. Manage. 48(2007), 1462–1471.
[30] Ghosal M.K., Tiwari G.N.: Modeling and parametric studies for thermal performance of an earth to air heat exchanger integrated with a greenhouse. Energy Convers. Manage. 47(2006), 1779–1798.
[31] Ahmed S.F., Amanullah M.T.O., Khan M.M.K., Rasul M., Hassan N.M.S.: Parametric study on thermal performance of horizontal earth pipe cooling system in summer. Energy Convers. Manage. 114(2016), 324–337. [32] Singh B., Kumar R., Asati A.K.: Influence of parameters on performance of Earth-to-air heat exchanger in hot-dry climate. J. Mech. Sci. Technol. 32(2018), 5457–5463.
[33] Liu Z., Yu Z., Yang T., Roccamena L., Sun P., Li S., Zhang G., Mankibi M.: Numerical modeling and parametric study of a vertical earth-to-air heat exchanger system. Energy 172(2019), 220–231.
[34] Hasan M.I., Noori S.W.: Study the potential of using Earth to air heat exchanger for cooling and heating of the residential buildings in Iraq. Heat Transf. – Asian Res. 48(2019), 9, 1–26.
[35] Ahmad S.N., Prakash O.: Earth air tube heat exchanger - A parametric study. In: Theoretical, Computational, and Experimental Solutions to Thermo-Fluid Systems (M. Palanisamy, V. Ramalingam, M. Sivalingam, Eds.), Lecture Notes in Mechanical Engineering. Springer 2021, 53–62.
[36] Amanowicz L., Wojtkowiak J.: Thermal performance of multi-pipe earth-to-air heat exchangers considering the non-uniform distribution of air between parallel pipes. Geothermics 88(2020), 1–11.
[37] Amanowicz L., Wojtkowiak J.: Approximated flow characteristics of multi-pipe earth-to-air heat exchangers for thermal analysis under variable airflow conditions. Renew. Energy 158(2020), 585–597.
[38] Sakhri N., Menni Y., Chamkha A.J., Lorenzini G., Ameur H., Kaid N., Bensafi M.: Experimental study of an earth-to-air heat exchanger coupled to the solar chimney for heating and cooling applications in arid regions. J. Therm. Anal. Calorim. 145(2020), 3, 1–10.
[39] Chel A., Tiwari G.: Stand-alone photovoltaic (PV) integrated with earth to air heat exchanger (eahe) for space heating/cooling of adobe house in New Delhi (India). Energy Convers. Manage. 51(2010), 393–409.
[40] Li H., Yu Y., Niu F., Shafik M., Chen B.: Performance of a coupled cooling system with earth-to-air heat exchanger and solar chimney. Renew. Energy 62(2014), 468–77.
[41] Maerefat M., Haghighi A.: Passive cooling of buildings by using integrated earth to air heat exchanger and solar chimney. Renew. Energy 35(2010), 2316–24.
[42] Singh B, Asati A., Kumar R.: Evaluation of the cooling potential of earth-to-air heat exchanger using concrete pipes. Int. J. Thermophys. 42(2021), 2, 1–19.
[43] Lee K.H., Strand R.K.: The cooling and heating potential of an earth tube system in buildings. Energy Build. 40(2008), 486–494.
[44] Zhao Y., Li R., Ji C., Huan C., Zhang B., Liu L.: Parametric study and design of an earth-to-air heat exchanger using model experiment for memorial heating and cooling. Appl. Therm. Eng. 148(2019), 838–845.
[45] Rosa N., Soares N., Costa J.J., Santos P., Gervasio H.: Assessment of an earth-air heat exchanger (EAHE) system for residential buildings in warm summer Mediterranean climate. Sustain. Energy Technol. Assess. 38(2020), 1–11.
[46] Misra A.K., Gupta M., Lather M., Garg H.: Design and performance evaluation of low-cost Earth to air heat exchanger model suitable for small buildings in arid and semi-arid regions. KSCE J. Civ. Eng. 19(2015), 4, 853–856.
[47] Yoon S., Lee S.R., Go G.H.: Evaluation of thermal efficiency in different types of horizontal ground heat exchangers. Energy Build. 105(2015), 100–105.
[48] Molcrette V.F.A., Autier V.R.B.: New expression to calculate quantity of recovered heat in the earth-pipe-air heat-exchanger operating in winter heating mode. Arch. Thermodyn. 41(2020), 2, 103–117
[49] Yang W., Lu P., Chen Y.: Laboratory investigations of the thermal performance of an energy pile with spiral coil ground heat exchanger. Energy Build. 128(2016), 491–502.
[50] Elminshawy N.A.S., Siddiqui F.R., Farooq Q.U., Addas M.F.: Experimental investigation on the performance of earth-air pipe heat exchanger for different soil compaction levels. Appl. Therm. Eng. 124(2017), 1319–1327.
[51] Kim M.J., Lee S.R., Yoon S., Jeon J.S.: An applicable design method for horizontal spiral-coil-type ground heat exchangers. Geothermics 72(2018), 338–347.
[52] Yusof T.M., Ibrahim H., Azmi W.H., Rejab M.R.M.: Thermal analysis of earthto- air heat exchanger using laboratory simulator. Appl. Therm. Eng. 134(2018), 130–140.
[53] Agrawal K.K., Misra R., Agrawal G.D.: Improving the thermal performance of ground air heat exchanger system using sand-bentonite (in dry and wet condition) as backfilling material. Renew. Energy 146(2020), 2008–2023.
[54] Mazarron F.R., Cid-Falceto J., Canas I.: Ground thermal inertia for energy efficient building design: A case study on food industry. Energies 5(2012), 2, 227–242.
[55] Mihalakakou G., Santamouris M., Asimakopoulos D.: Modelling the thermal performance of earth-to-air heat exchangers. Sol. Energy 53(1994), 3, 301–305.
[56] Badescu V.: Simple and accurate model for the ground heat exchanger of a passive house. Renew. Energy 32(2007), 5, 845–855.
[57] Mathur A., Srivastava J., Mathur S., Agrawal G.D.: Transient effect of soil thermal diffusivity on performance of EATHE system. Energy Rep. 1(2015), 17–21.
[58] Zhang N., Wang Z.: Review of soil thermal conductivity and predictive models. Int. J. Therm. Sci. 117(2017), 172–183.
[59] Holman J.P.: Experimental Methods for Engineers (8th Edn.). Tata McGraw-Hill, New York 2007.
[60] Bansal V., Misra R., Agrawal G.D., Mathur J.: Performance analysis of earthpipe- air heat exchanger for winter heating. Energy Build. 41(2009), 11, 1151–1154.
Go to article

Authors and Affiliations

Saif Nawaz Ahmad
1
Om Prakash
1

  1. National Institute of Technology Patna, Bihar 800005, India

This page uses 'cookies'. Learn more