Search results

Filters

  • Journals
  • Authors
  • Keywords
  • Date
  • Type

Search results

Number of results: 289
items per page: 25 50 75
Sort by:
Download PDF Download RIS Download Bibtex

Abstract

Heating of steel or structural aluminum alloys at a speed of 2 to 50 K/min – characterizing the fire conditions – leads to a reduction in mechanical properties of the analyzed alloys. The limit of proportionality fp, real fy and proof f₀₂ yield limit, breaking strength fu and longitudinal limit of elasticity E decrease as the temperature increases. Quantitative evaluation of the thermal conversion in strengths of structural alloys is published in Eurocodes 3 and 9, in the form of dimensionless graphs depicting reduction coefficients and selected (tabulated) discrete values of mechanical properties. The author’s proposal for an analytical formulation of code curves describing thermal reduction of elasticity modulus and strengths of structural alloys recommended for an application in building structures is presented in this paper.

Go to article

Authors and Affiliations

M. Gwóźdź
Download PDF Download RIS Download Bibtex

Abstract

The aim of this document is to present the topic of modeling district heating systems in order to enable optimization of their operation, with special focus on thermal energy storage in the pipelines. Two mathematical models for simulation of transient behavior of district heating networks have been described, and their results have been compared in a case study. The operational optimization in a DH system, especially if this system is supplied from a combined heat and power plant, is a difficult and complicated task. Finding a global financial optimum requires considering long periods of time and including thermal energy storage possibilities into consideration. One of the most interesting options for thermal energy storage is utilization of thermal inertia of the network itself. This approach requires no additional investment, while providing significant possibilities for heat load shifting. It is not feasible to use full topological models of the networks, comprising thousands of substations and network sections, for the purpose of operational optimization with thermal energy storage, because such models require long calculation times. In order to optimize planned thermal energy storage actions, it is necessary to model the transient behavior of the network in a very simple way – allowing for fast and reliable calculations. Two approaches to building such models have been presented. Both have been tested by comparing the results of simulation of the behavior of the same network. The characteristic features, advantages and disadvantages of both kinds of models have been identified. The results can prove useful for district heating system operators in the near future.

Go to article

Authors and Affiliations

Michał Leśko
Wojciech Bujalski
Download PDF Download RIS Download Bibtex

Abstract

The analyzed heat accumulator is a key element in a hybrid heating system. In this paper, analytical and numerical models of the ceramic heat accumulator are presented.The accuracy of finite difference methods will be assessed by comparing the results with those obtained from the exact analytical solution.

Go to article

Authors and Affiliations

Dawid Taler
Piotr Cisek
Download PDF Download RIS Download Bibtex

Abstract

The article presents the results of surveys to assess the attractiveness of centralized heat supply systems in comparison with other heat sources. The heat source is an important element of the heat supply system which determines heating costs, comfort and environmental impact. The decision on the choice of the type of heat supply system is usually made by the investor or designer. Sometimes the equipment supplier or contractor has a part in this decision. The choice can be influenced by many different factors, also resulting from the specific location of the building. This is only partly determined by local law in the form of a local spatial development plan. the technical conditions (i.e. availability of heating or gas network), economic and financial, as well as much more subjective factors, such as the designer’s or contractor’s preference are also important. Aversion to district heating is growing, even when there are favorable conditions and the possibility of connecting the building to the heating network. Instead, a gas boiler or electrically powered heat pump is selected. This raises the question of whether such decisions are right and how they can be justified. As a research method, surveys were used, which were conducted among people who already have or will have an impact on design and investment decisions in the near future. The obtained results confirmed a large interest in district heating, appreciating their advantages in comparison with other methods of heat generation. The respondents also had the disadvantages that may lead to the use of an alternative methods of heat supplying in mind.

Go to article

Authors and Affiliations

Grzegorz Bartnicki
Bogdan Nowak
Download PDF Download RIS Download Bibtex

Abstract

The paper presents the methodology of designing a system for accumulating waste heat from industrial processes. The research aimed to analyse the fluid’s movement in the heat accumulator to unify the temperature field in the volume of water constituting the heat buffer. Using the computer program Ansys Fluent, a series of computational fluid dynamics simulations of the process of charging the heat storage with water at 60°C, 70°C, and 80°C was carried out. The selected temperatures correspond to the temperature range of unmanaged waste heat. In the presented solution, heat storage is loaded with water from the cooling systems of industrial equipment to store excess heat and use it at a later time. The results of numerical calculations were used to analyse the velocity and temperature fields in the selected structure of the modular heat storage. A novelty in the presented solution is the use of smaller modular heat storage units that allow any configuration of the heat storage system. This solution makes it possible to create heat storage with the required heat capacity.
Go to article

Authors and Affiliations

Piotr Górszczak
1
Marcin Rywotycki
1
Marcin Hojny
1
Grzegorz Filo
2

  1. AGH University of Krakow, Mickiewicza 30, 30-059 Kraków, Poland
  2. Cracow University of Technology, Jana Pawła II 37, 31-864 Kraków, Poland
Download PDF Download RIS Download Bibtex

Abstract

The article addresses the issues falling within the scope of the economic analysis of a detached building’s heating system with a direct evaporation ground source heat pump installation. The paper was elaborated based on the data made available by the investment’s contractor and the investor. The paper provides data on the investment expenditures and utility cost, calculations of the installation payback, internal return rate and the current net value.
Go to article

Authors and Affiliations

Karol Tucki
Michał Sikora
Magdalena Karlikowska
Wojciech Będkowski
Download PDF Download RIS Download Bibtex

Abstract

The article analyses selected aspects of the technology and logistics used to modernise a coal-fired heating plant to switch to woodchips, which is illustrated with a specific investment. The study presents characteristics of the investment’s heat economy before the modernisation, as well as the assumptions and program of the project. Finally, selected effects of the modernisation have been described
Go to article

Authors and Affiliations

Karol Tucki
Michał Sikora
Download PDF Download RIS Download Bibtex

Abstract

In the paper presented are experiences from operation of three different expansion devices for possible implementation in the domestic micro CHP. These were the modified scroll expander and two designs based on the variable working chamber volume pneumatic devices. Experiments showed the superiority of both "pneumatic devices" over the scroll expander, indicating the possible internal efficiencies in the range of 61 82Such efficiencies are very attractive, especially at the higher end of that range. The volume of these devices is much smaller than the scroll expander which makes it again more suitable for a domestic micro CHP. Small rotational velocities enable to conclude that connection to electricity grid will also be simpler in the case of "pneumatic devices". The "pneumatic devices" under scrutiny here could be an alternative to the typical vapour turbine in the ORC cycle, which is in the process of development at the IFFM.

Go to article

Authors and Affiliations

Dariusz Mikielewicz
Jarosław Mikielewicz
Jan Wajs
Download PDF Download RIS Download Bibtex

Abstract

Instantaneous acoustic heating of a viscous fluid flow in a boundary layer is the subject of investigation. The governing equation of acoustic heating is derived by means of a special linear combination of conservation equations in the differential form, which reduces all acoustic terms in the linear part of the final equation but preserves terms belonging to the thermal mode. The procedure of decomposition is valid in a weakly nonlinear flow, it yields the nonlinear terms responsible for the modes interaction. Nonlinear acoustic terms form a source of acoustic heating in the case of the dominative sound. This acoustic source reflects the thermoviscous and dispersive properties of a fluid flow. The method of deriving the governing equations does not need averaging over the sound period, and the final governing dynamic equation of the thermal mode is instantaneous. Some examples of acoustic heating are illustrated and discussed, and conclusions about efficiency of heating caused by different waveforms of sound are made.

Go to article

Authors and Affiliations

Anna Perelomova
Weronika Pelc-Garska
Download PDF Download RIS Download Bibtex

Abstract

In this study the authors minimise the total process cost for the heating of solid particles in a horizontal fluidised bed by an optimal choice of the inlet heating gas temperature profile and the total gas flow. Solid particles flowed along the apparatus and were heated by a hot gas entering from the bottom of the fluidised apparatus. The hydrodynamics of the fluidised bed is described by a two-phase Kunii - Levenspiel model. We assumed that the gas was flowing only vertically, whereas solid particles were flowing horizontally and because of dispersion they could be additionally mixed up in the same direction. The mixing rate was described by the axial dispersion coefficient. As any economic values of variables describing analysing process are subject to local and time fluctuations, the accepted objective function describes the total cost of the process expressed in exergy units. The continuous optimisation algorithm of the Maximum Principle was used for calculations. A mathematical model of the process, including boundary conditions in a form convenient for optimisation, was derived and presented. The optimization results are presented as an optimal profile of inlet gas temperature. The influence of heat transfer kinetics and dispersion coefficients on optimal runs of the heating process is discussed. Results of this discussion constitute a novelty in comparison to information presented in current literature.

Go to article

Authors and Affiliations

Zbigniew Szwast
Artur Poświata
Download PDF Download RIS Download Bibtex

Abstract

The numerical simulation of the heat transfer in the flow channels of the minichannel heat exchanger was carried out. The applied model was validated on the experimental stand of an air heat pump. The influence of louver heights was investigated in the range from 0 mm (plain fin) to 7 mm (maximum height). The set of simulations was prepared in Ansys CFX. The research was carried out in a range of air inlet velocities from 1 to 5 m/s. The values of the Reynolds number achieved in the experimental tests ranged from 93 to 486. The dimensionless factors, the Colburn factor and friction factor, were calculated to evaluate heat transfer and pressure loss, respectively. The effectiveness of each louver height was evaluated using the parameter that relates to the heat transfer and the pressure drop in the airflow. The highest value of effectiveness (1.53) was achieved by the louver height of 7 mm for the Reynolds number of around 290.
Go to article

Authors and Affiliations

Artur Romaniak
1
Michał Jan Kowalczyk
1
Marcin Łęcki
1
Artur Gutkowski
1
Grzegorz Górecki
1

  1. Lodz University of Technology, Zeromskiego 116, 90-924 Łódz, Poland
Download PDF Download RIS Download Bibtex

Abstract

Recent dynamic changes in global fossil fuels markets and the European carbon dioxide emission allowances system have significantly impacted the energy sectors. These fluctuations also influence district heating (DH) markets where coal and natural gas remain dominant energy vectors in numerous European countries. District heating markets are distinct from other commodity markets due to their local nature and distribution requirements. Consequently, they can operate under various market models and have different price design policies depending on the country and region. With these considerations, this study aims to review and analyse the current market models and regulations of price formulation in the context of final prices in selected district heating markets. The primary objective is to conduct an in-depth analysis of the key district heating markets in Poland and compare the outcomes with the markets of neighbouring countries, including the Czech Republic, Slovakia, Lithuania, Latvia, Estonia, and Germany. Poland is taken as an example due to its high dependence on fossil fuels and its vulnerability to current global price fluctuations. The results indicate that Poland has one of the most regulated district heating markets, and these regulations can impact the profitability of district heating companies with high prices of fuel and carbon certificates observed in global markets. To create incentives for potential investors and incumbent companies to develop more sustainable and low-emission district heating markets in Poland – where energy transition processes are still underway – it is recommended to increase the frequency of formulation and approval of tariffs.
Go to article

Authors and Affiliations

Aleksandra Komorowska
1
ORCID: ORCID
Tomasz Surma
2

  1. Mineral and Energy Economy Research Institute of the Polish Academy of Sciences, Kraków
  2. Veolia Energia Polska SA, Poland
Download PDF Download RIS Download Bibtex

Abstract

Adsorption refrigeration systems are able to work with heat sources of temperature starting with 50°C. The aim of the article is to determine whether in terms of technical and economic issues adsorption refrigeration equipment can work as elements that produce cold using hot water from the district heating network. For this purpose, examined was the work of the adsorption air conditioning equipment cooperating with drycooler, and the opportunities offered by the district heating network in Warsaw during the summer. It turns out that the efficiency of the adsorption device from the economic perspective is not sufficient for production of cold even during the transitional period. The main problem is not the low temperature of the water supply, but the large difference between the coefficients of performance, COPs, of adsorption device and a traditional compressor air conditioning unit. When outside air temperature is 25°C, the COP of the compressor type reaches a value of 4.49, whereas that of the adsorption device in the same conditions is 0.14. The ratio of the COPs is 32. At the same time ratio between the price of 1 kWh of electric power and 1 kWh of heat is only 2.85. Adsorption refrigeration equipment to be able to compete with compressor devices, should feature COPads efficiency to be greater than 1.52. At such a low driving temperature and even changing the drycooler into the evaporative cooler it is not currently possible to achieve.
Go to article

Authors and Affiliations

Artur Rusowicz
Andrzej Grzebielec
Maciej Jaworski
Rafał Laskowski
Download PDF Download RIS Download Bibtex

Abstract

In the paper a heating system with a vapour compressor heat pump and vertical U-tube ground heat exchanger for small residential house is considered. A mathematical model of the system: heated object - vapour compressor heat pump - ground heat exchanger is presented shortly. The system investigated is equipped, apart from the heat pump, with the additional conventional source of heat. The processes taking place in the analyzed system are of unsteady character. The model consists of three elements; the first containing the calculation model of the space to be heated, the second - the vertical U-tube ground heat exchanger with the adjoining area of the ground. The equations for the elements of vapour compressor heat pump form the third element of the general model. The period of one heating season is taken into consideration. The results of calculations for two variants of the ground heat exchanger are presented and compared. These results concern variable in time parameters at particular points of the system and energy consumption during the heating season. This paper presents the mutual influence of the ground heat exchanger subsystem, elements of vapour compressor heat pump and heated space.

Go to article

Authors and Affiliations

Małgorzata Hanuszkiewicz-Drapała
Jan Składzień
Download PDF Download RIS Download Bibtex

Abstract

Exergy analysis of low temperature geothermal heat plant with compressor and absorption heat pump was carried out. In these two concepts heat pumps are using geothermal water at 19.5°C with spontaneous outflow 24 m3/h as a heat source. The research compares exergy efficiency and exergy destruction of considered systems and its components as well. For the purpose of analysis, the heating system was divided into five components: geothermal heat exchanger, heat pump, heat distribution, heat exchanger and electricity production and transportation. For considered systems the primary exergy consumption from renewable and non-renewable sources was estimated. The analysis was carried out for heat network temperature at 50/40°C, and the quality regulation was assumed. The results of exergy analysis of the system with electrical and absorption heat pump show that exergy destruction during the whole heating season is lower for the system with electrical heat pump. The exergy efficiencies of total system are 12.8% and 11.2% for the system with electrical heat pump and absorption heat pump, respectively.

Go to article

Authors and Affiliations

Robert Sekret
Anna Nitkiewicz
Download PDF Download RIS Download Bibtex

Abstract

The article presents a numerical model of the concrete heat accumulator for solar heating systems. Model uses control volume finite element method with an explicit solution method for time integration. The use of an explicit method is an essential advantage in the simulation of time-dependent changes in temperature of the air at the accumulator inlet. The study compares the results of numerical model calculations of the accumulator heating with experimental measurements and with computational fluid dynamics modeling. The comparison shows a good correlation between the results of calculation using the model and the results of measurements.
Go to article

Authors and Affiliations

J. Sacharczuk
D. Taler
Download PDF Download RIS Download Bibtex

Abstract

This paper presents the results of thermodynamic analyses of a system using a horizontal ground heat exchanger to cool a residential building in summer and heat it in the autumn-winter period. The main heating device is a vapour compression heat pump with the ground as the lower heat source. The aim of the analyses is to examine the impact of heat supply to the ground in the summer period, when the building is cooled, on the operation of the heating system equipped with a heat pump in the next heating season, including electricity consumption. The processes occurring in cooling and heating systems have an unsteady nature. The main results of the calculations are among others the time-dependent values of heat fluxes extracted from or transferred to the ground heat exchanger, the fluxes of heat generated by the heat pump and supplied to the heated building by an additional heat source, the parameters in characteristic points of the systems, the temperature distributions in the ground and the driving electricity consumption in the period under analysis. The paper presents results of analysis of cumulative primary energy consumption of the analyzed systems and cumulative emissions of harmful substances.

Słowa kluczowe

Go to article

Authors and Affiliations

Małgorzata Hanuszkiewicz-Drapała
Tomasz Bury
Download PDF Download RIS Download Bibtex

Abstract

This study is devoted to the instantaneous acoustic heating of a shear-thinning fluid. Apparent viscosity of a shear-thinning fluid depends on the shear rate. That feature distinguishes it from a viscous Newtonian fluid. The special linear combination of conservation equations in the differential form makes it possible to derive dynamic equations governing both the sound and non-wave entropy mode induced in the field of sound. These equations are valid in a weakly nonlinear flow of a shear-thinning fluid over an unbounded volume. They both are instantaneous, and do not require a periodic sound. An example of a sound waveform with a piecewise constant shear rate is considered as a source of acoustic heating.

Go to article

Authors and Affiliations

Anna Perelomova
Download PDF Download RIS Download Bibtex

Abstract

This paper presents a mathematical model of a power controller for a high-frequency induction heating system based on a modified half-bridge series resonant inverter. The output real power is precise over the heating coil, and this real power is processed as a feedback signal that contends a closed-loop topology with a proportional-integral-derivative controller. This technique enables both control of the closed-loop power and determination of the stability of the high-frequency inverter. Unlike the topologies of existing power controllers, the proposed topology enables direct control of the real power of the high-frequency inverter.

Go to article

Authors and Affiliations

Palash Pal
Debabrata Roy
Avik Datta
Pradip K. Sadhu
Atanu Banerjee
Download PDF Download RIS Download Bibtex

Abstract

It can be expected that there is a considerable correlation between combustion air flow rate and the concentrations of carbon monoxide, hydrocarbons and nitrogen oxide in the flue gas. The influence of temperature and oxygen concentration in the combustion zone on the concentrations of carbon monoxide, hydrocarbons and nitrogen oxide in the flue gas, for high and low combustion air flow, was analysed. Oxygen concentration for which the concentration of carbon monoxide is the lowest was determined, as well as the mutual relation between carbon monoxide and nitrogen oxide concentration.

Go to article

Authors and Affiliations

Marek Juszczak
Download PDF Download RIS Download Bibtex

Abstract

The organo-inorganic commercial binder Albertine F/1 (Hüttenes-Albertus) constituting the starch-aluminosilicate mixture was directed to structural studies. The paper presents a detailed structural analysis of the binder before and after exposure to physical curing agents (microwaves, high temperature) based on the results of infrared spectroscopy studies (FTIR). An analysis of structural changes taking place in the binder system with the quartz matrix was also carried out. Based on the course of the obtained IR spectra, it was found that during the exposure on physical agents there are structural changes within the hydroxyl groups in the polymeric starch chains and silanol groups derived from aluminosilicate as well as in the quartz matrix (SiO2). The curing of the molding sand takes place due to the evaporation of the solvent water and the formation of intramolecular and intermolecular cross-linking hydrogen bonds. Type and amount of hydrogen bonds presence in cured molding sand have an impact on selected properties of molding sand. Results indicates that for molding sand with Albertine F/1 during conventional heating a more extensive network of hydrogen bonds is created.
Go to article

Authors and Affiliations

S. Żymankowska-Kumon
B. Grabowska
A. Bobrowski
K. Kaczmarska
S. Cukrowicz
Download PDF Download RIS Download Bibtex

Abstract

Detailed studies on the effects of pulsed laser interference heating on surface characteristics and subsurface microstructure of amorphous Fe80Si11B9 alloy are reported. Laser interference heating, with relatively low pulsed laser energy (90 and 120 mJ), but with a variable number (from 50-500) of consecutive laser pulses permitted to get energy accumulation in heated areas. Such treatment allowed to form two- Dimensional micro-islands of laser-affected material periodically distributed in amorphous matrix. The crystallization process of amorphous FeSiB ribbons was studied by means of scanning and transmission electron microscopy. Detailed microstructural examination showed that the use of laser beam, resulted in development of nanostructure in the heated areas of the amorphous ribbon. The generation of nanocrystalline seed islands created by pulsed laser interference was observed. This key result may evidently give new knowledge concerning the differences in microstructure formed during the conventional and lased induced crystallization the amorphous alloys. Further experiments are needed to clarify the effect of pulsed laser interference crystallization on magnetic properties of these alloys.
Go to article

Authors and Affiliations

J. Morgiel
R. Ostrowski
J. Kusiński
O. Czyż
A. Radziszewska
M. Strzelec
C. Czyż
A. Rycyk

This page uses 'cookies'. Learn more