This paper presents a finite element investigation into the proximity losses in a high-speed permanent magnet (PM) machine for traction applications. A three-dimensional (3D) finite element analysis (FEA) is employed to evaluate and identify the endwinding contribution into the overall winding power loss generated. The study is focused on the end-winding effects that have not been widely reported in the literature. The calculated results confirm that the end-winding copper loss can significantly affect the eddycurrent loss within copper and it should be taken into account to provide reasonable prediction of total losses. Several structures of the end-winding are analyzed and compared in respect to the loss and AC resistance. The results clearly demonstrate that the size of the end-winding has a significant impact on the power loss. The calculated results are validated experimentally on the high-speed permanent magnet synchronous machine (PMSM) prototype for selected various winding arrangements.
The purpose of this paper is to focus on the loss separation of non-grain-oriented electrical steels used for speed-variable rotating electrical machines. The impact of laser-cutting, used in prototype manufacturing and of flux density harmonics, occurring locally in the lamination, on the loss distribution is studied in detail. Iron losses occurring under operation can physically be separated in different loss components. In this paper, a frequency-based loss model with parameters identified for single-sheet tester specimens, cut in strips of different widths, is therefore used. Moreover, a time-domain approach considers loss distributions occurring from higher harmonics. Hysteresis losses having high sensitivity to cut edge effects are calculated by the well-known Jiles-Atherton model adapting the frequency-based loss parameters. The model is validated by free-curve measurements at a single-sheet tester. It has been shown that the studied elliptical hysteresis model becomes inaccurate particularly for specimens with small strip widths with similar dimensions as teeth of electrical machine laminations. The incorrect mapping of losses occurring from minor hysteresis loops due to higher harmonics is concluded. The results showconsequently that both, the impact of a cut edge effect and local distributions of flux density harmonics need to be considered in terms of accurate iron loss prediction of electrical machine design.
The male protagonists of Barbey’s Norman novel cycle are characterized by a strong, even steadfast will. Despite this, regardless of the circumstances, each of them is defeated, contributing to the misfortune of others. They fail to achieve happiness, fulfill even the most noble mission or achieve a goal. This is because their fate is inseparably connected with Barbey's vision of the world and the philosophy of history.
Szargut proposed the algorithm for determination of the influence of irreversibility of components of thermal process on the emission of CO2 [6]. In the presented paper, basing on Szargut's proposal, the example of analysis of influence of operational parameters of coal fired power plant on the local increase of CO2 emission is presented. The influence of operational parameters on the local exergy losses appearing in components of investigated power plant are simulating making use of the semi-empirical model of power plant.
The aim of study was to investigate the effect of nutrient solution leakage during plant cultivation in greenhouse on soil pollution. Investigations were conducted in horticultural farms in the Wielkopolskie province (Greater Poland), specializing in soilless plant cultivation in greenhouse. In the first farm located on sandy soil tomato has been grown since its establishment (Object A). Prior to the beginning of crop culture soil samples were collected for analyses at every 0.2 m layer, to the depth of one meter. Successive samples were taken also in autumn after the completion of 1, 2, 3 and 7 culture cycles. For comparison, research was also conducted in a greenhouse located on loamy sand/sandy loam soil used for 8 years for tomato culture (Object B). In all these facilities plants in rockwool were grown and the fertigation in an open system was provided. Chemical analyzes showed the dynamics of soil properties changes and vertical distribution of cations and anions within the soil profile. Increased content of almost all nutrients and particularly of S-SO4, P, K, Zn, N-NH4, N-NO3 in the soil profile in object A and S-SO4, K, P, N-NO3 in the soli profile in object B were recorded. The results showed that the degradation rate of the soil environment as a result of open fertigation system application depends primarily on the duration of greenhouse operation. However, explicit changes in the chemical properties of soils were observed already after the first growth cycle. Smaller doses of fertilizers and water, and in consequence reduction of nutrients losses may be achieved by closed fertigation systems.
The paper presents the problem of sensorless control of a permanent magnets synchronous motor (PMSM) without a damping cage for fan applications. Frequency control was used according to the principle of v/f = const. In order to reduce the power consumption of the drive system, the optimal voltage to the motor frequency characteristics was tested in the laboratory. The experimental studies was performed on a laboratory set of a drive consisting of two coupled PMSM machines, where one machine was supplied by a transistor inverter and the other was a passive load. A new criterion based on minimizing the module of stator current vector was proposed and an optimization algorithm in steady states was tested. The results of laboratory tests confirmed the validity of the applied solution for the fan drive.
The primary evaluation of the economic losses caused by water pollution in Shanghai in the year 2009 is made by classification approach in order to provide basis for decision of the relative water management policy. The result shows that the portion of water pollution losses in GDP of Shanghai was 2.7%, which was still lower than the average level of whole China despite of the local high population density and the scale of industry, suggesting to some extent the continuous attention in water protection paid by Shanghai government.
The aim of this paper is presentation and comparison of calculation methods of the inductance matrix of a 3-column multi-winding autotransformer. Main and leakage autotransformer inductance was obtained using finite elements method. Static calculations were made at the current supply for 2D and 3D models, and mono-harmonic calculations were made at the voltage supply. In the mono-harmonic calculations the eddy current losses were taken into account, this made it possible to study relationship between the autotransformer parameters and the frequency. Calculations were made using Ansys and the authors' own programs in Matlab.
The 15-winding and 3-column autotransformer supplying an 18-pulse rectifier circuit was developed. Presented methods can be used also for the autotransformers of other topologies supplying different kinds of converters. Presented methods make it possible to exactly calculate main and leakage inductances of the multi-winding autotransformer. The presented analysis of the eigenvalues and eigenvectors of the inductance matrix makes it possible to identify the influence nature of individual modes on the inductance matrix, and to compare the calculation results obtained using the presented methods. Frequency dependence of autotransformer parameters was shown. Also modes of the impedance matrix of the multi-winding autotransformer was investigated, this made it possible to identify the influence nature of individual modes on the inductance matrix. Using presented methods one can exactly calculate main and leakage inductances of the autotransformer. Thanks to this, one can design in optimal way autotransformers for supplying, for example, rectifier circuits, THD coefficients. The results of the measurements and simulations were also shortly presented at the end of the article.
The results of the eddy currents losses calculations with using electrodynamics scaling were presented in this paper. Scaling rules were used for obtain the values of the eddy currents losses. For the calculations Finite Element Method was used. Numerical calculations were verified by measurements and a good agreement was obtained.
High distribution system power-losses are predominantly due to lack of investments in R&D for improving the efficiency of the system and improper planning during installation. Outcomes of this are un-designed extensions of the distributing power lines, the burden on the system components like transformers and overhead (OH) lines/conductors and deficient reactive power supply leading to drop in a system voltage. Distributed generation affects the line power flow and voltage levels on the system equipment. These impacts of distributed generation (DG) may be to improve system efficiency or reduce it depending on the operating environment/conditions of the distribution system and allocation of capacitors. For this purpose, allocating of distributed generation optimally for a given radial distribution system can be useful for the system outlining and improve efficiency. In this paper, a new method is used for optimally allocating the DG units in the radial distribution system to curtail distribution system losses and improve voltage profile. Also, the variation in active power load in the system is considered for effective utilization of DG units. To evidence the effectiveness of the proposed algorithm, computer simulations are carried out in MATLAB software on the IEEE-33 bus system and Vastare practical 116 bus system.
This paper contains the result of the comparison of photogrammetric records of the state of the front zone of the Werenskiold Glacier over the period 1957-1978. Two 1:5000 maps were compared. The ice volume loss at 20 m altitude intervals (only as far up as 200 m over the sea level) and changes in the ice thickness were analysed with a network of basic squares with a 50 m side in the field, using an Odra 1305 computer. This permitted a map of the altitude changes in the glacier front to be plotted with isolines every 2.5 m. The results of the photogrammetric investigations were compared with ablation observations using ablations stakes. Taking account of the motion of the lobe the total and the mean annual ice volume loss in the front zone of the Werenskiold Glacier was evaluated for the period in question.
The aim of this study was to evaluate the hearing status of call centre operators in relation to their noise exposure. Conventional pure-tone audiometry and extended high-frequency audiometry were performed in 49 workers, aged 22–47 years (mean ± SD: 32.0 ± 6.0 years), working in call centre from 1.0 to 16.5 years (mean ± SD: 4.7 ± 2.9 years).
Questionnaire inquiry aimed at collecting personal data, the information on ommunication headset usage habits, self-assessment of hearing ability and identification of risk factors for noise-induced hearing loss were also carried out. Sound pressure levels generated by the communication headset were determined using the artificial ear technique specified in CSA Z107.56-13 (2013) standard. The background noise prevailing in offices was also measured according to PN-N-01307 (1994) and PN-EN ISO 9612 (2011).
Personal daily noise exposure levels in call centre operators varied from 66 to 86 dB (10–90th percentile). About half of the study subjects had normal hearing in the standard frequencies (from 250 to 8000 Hz) in both ears, while only 27.1% in the extended high-frequencies (9–16 kHz). Moreover, both high-frequency and speech-frequency hearing losses were observed in less than 10% of audiograms, while the extended high-frequency threshold shift was noted in 37.1% of analysed ears. The hearing threshold
levels of call centre operators in the frequency of 0.25–11.2 kHz were higher (worse) than the expected median values for equivalent (due to age and gender) highly screened population specified in ISO 7029 (2017). Furthermore, they were also higher than predicted for 500–4000 Hz according to ISO 1999 (2013) based on the results of noise exposure evaluation.
The head loss is a decrease in compressive height caused by friction and direction changes of flow at the sliced bend. This method expected to provide is easy, fast, and economical. The elements of influence are the velocity of flow, the num-ber of slices, average length of sliced walls, angle changes of the sliced, coefficient of friction, acceleration of gravity, and slope of the pipe. Equation for coefficient of head loss (Kb) is an analysis method for the head loss (hL) calculation. The analysis results that have obtained are the larger diameter of the pipe, and the more slices with a fixed discharge, the coefficient of hL becomes small. Conversely, if the diameter of the pipe is getting smaller, and the slice is getting less, then the coefficient of hL becomes bigger. This method, expected to give new knowledge in pipeline network applications, especially for the large diameter of pipelines.
The increased power density, reduced switching losses with minimum electromagnetic interference (EMI), and high efficiency are essential requirements of power converters. To achieve these characteristics, soft power converters employing soft switching techniques are indispensable. In this paper, a ZCS/ZVS PWM AC/DC converter topology has been emphasized, which finds applications in high power systems such as automobile battery charging and renewable energy systems. This converter scheme maintains zero current and zero voltage switching conditions at turn on and turn off moments of semiconductor switches, respectively and soft operation of rectifier diodes that lead to negligible switching and diode reverse recovery losses. Moreover, it improves power quality and presents high input power factor, low total harmonic distortion of the input current (THDI) and improved efficiency. The validity of theoretical analysis of the proposed converter has been carried out experimentally on a 10 kW laboratory prototype. Experimental results prove that the soft switching operation of the semiconductor switches and diodes is maintained at 98.6% rated load efficiency. In addition, the performance evaluation has been performed by comparative analysis of the proposed converter with some prior art high power AC/DC converters. Efficiencies of the proposed and prior art high power topologies have been determined for different load conditions. The highest efficiency, power factor and lower THDI of the proposed converter topology complies with international standards.
The paper presents equations of a mathematical model to calculate flow parameters in characteristic cross-sections in the steam-water injector. In the model, component parts of the injector (steam nozzle, water nozzle, mixing chamber, condensation wave region, diffuser) are treated as a series of connected control volumes. At first, equations for the steam nozzle and water nozzle are written and solved for known flow parameters at the injector inlet. Next, the flow properties in two-phase flow comprising mixing chamber and condensation wave region are determined from mass, momentum and energy balance equations. Then, water compression in diffuser is taken into account to evaluate the flow parameters at the injector outlet. Irreversible losses due to friction, condensation and shock wave formation are taken into account for the flow in the steam nozzle. In two-phase flow domain, thermal and mechanical nonequilibrium between vapour and liquid is modelled. For diffuser, frictional pressure loss is considered. Comparison of the model predictions with experimental data shows good agreement, with an error not exceeding 15% for discharge (outlet) pressure and 1 K for outlet temperature.