Search results

Filters

  • Journals
  • Authors
  • Keywords
  • Type

Search results

Number of results: 3
items per page: 25 50 75
Sort by:
Download PDF Download RIS Download Bibtex

Abstract

The dynamic performance of cylindrical double-tube adsorption heat pump is numerically analysed using a non-equilibrium model, which takes into account both heat and mass transfer processes. The model includes conservation equations for: heat transfer in heating/cooling fluids, heat transfer in the metal tube, and heat and mass transfer in the adsorbent. The mathematical model is numerically solved using the method of lines. Numerical simulations are performed for the system water-zeolite 13X, chosen as the working pair. The effect of the evaporator and condenser temperatures on the adsorption and desorption kinetics is examined. The results of the numerical investigation show that both of these parameters have a significant effect on the adsorption heat pump performance. Based on computer simulation results, the values of the coefficients of performance for heating and cooling are calculated. The results show that adsorption heat pumps have relatively low efficiency compared to other heat pumps. The value of the coefficient of performance for heating is higher than for cooling

Go to article

Authors and Affiliations

Kinga Kowalska
Bogdan Ambrożek
Download PDF Download RIS Download Bibtex

Abstract

The results of bearing capacity, deformability and fracture toughness of reinforced concrete beams with the external reinforcement in the form of steel cut and stretchy sheet, obtained due to the conducting of the experiment and mathematical simulation which were made of concrete of C40/50 class are given in the article. Mathematical simulation of beam structures is done on the basis of the deformation model which allows to conduct calculations of the unified methodological positions of different elements with diverse configuration of cross section and reinforcement as well as take into consideration elastic and plastic properties of concrete and reinforcement, assessing the actual stress-strain state of sections of reinforced concrete elements at different loading levels, including ultimate one. The deformation model is based on the actual diagrams use of concrete and reinforcement materials deformation and conditions of efforts balance in the normal section and hypothesis of flat sections. The theoretical value of bearing capacity and deformability, obtained as a result of the mathematical simulation was compared to the experimental data. The satisfactory coincidence of the mathematical calculation of bearing capacity, deformability, fracture toughness and experimental data gives an opportunity to use the algorithm not only for beam structures with bar reinforcement but also for beam structures with the external reinforcement in the form of steel cut and stretchy sheet.
Go to article

Authors and Affiliations

Sofiya Burchenya
Shmyh Roman
Download PDF Download RIS Download Bibtex

Abstract

The aim of the study was to model the operation of a wastewater treatment plant using the Monte Carlo method and selected probability distributions of random variables. Pollutant indices in treated wastewater were analysed, such as: biological oxygen demand ( BOD 5), chemical oxygen demand ( COD Cr), total suspended solids ( TSS), total nitrogen (N tot), total phosphorus (P tot). The preliminary analysis of pollution indicators series included the: calculation of descriptive statistics and assessment of biological degradability of wastewater. The consistency of the theoretical distributions with the empirical ones was assessed using Anderson–Darling statistics. The best-fitting statistical distributions were selected using the percent bias criterion. Based on the calculations performed, it was found that the analysed indicators of pollution in treated wastewater were characterised by an average variability of composition for BOD 5, COD Cr and TSS, and a high variability of composition for N tot and P tot. The best fitted distribution was log-normal for BOD 5, TSS, N tot and P tot and general extreme values for COD Cr. The simulation carried out using the Monte-Carlo method confirmed that there may be problems associated with the reduction of nutrients (N tot and P tot) the analysed wastewater treatment plant. Results of values obtained of the risk values of negative control of wastewater treatment plant operation for biogenic compounds, different from 1, indicate that the number of exceedances at the outflow may be higher than the acceptable one.
Go to article

Authors and Affiliations

Karolina Migdał
1
ORCID: ORCID
Agnieszka Operacz
1
ORCID: ORCID
Iryna Vaskina
2
ORCID: ORCID
Paulina Śliz
3
ORCID: ORCID
Jorge Tavares
4 5
ORCID: ORCID
Adelaide Almeida
4 5 6
ORCID: ORCID
Michał Migdał
7

  1. University of Agriculture in Krakow, Faculty of Environmental Engineering and Land Surveying, Department of Sanitary Engineering and Water Management, al. Mickiewicza 24/28, 30-059 Kraków, Poland
  2. Sumy State University, Faculty of Technical System and Energy Efficient Technologies, Department of Applied Ecology, Sumy, Ukraine
  3. Cracow University of Economics, Institute of Spatial Management and Urban Studies, Department of Spatial Management, Kraków, Poland
  4. Polytechnic Institute of Beja, Department of Technology and Applied Sciences, Beja, Portugal
  5. University of Beira Interior, Faculty of Engineering, Research Unit Fiber Materials and Environmental Technologies (FibEnTech-UBI), Covilhã, Portugal
  6. University Nova of Lisbon, Faculty of Science and Technology, Center for Environmental and Sustainability Research (CENSE), Lisbon, Portugal
  7. Stalprodukt S.A., Bochnia, Poland

This page uses 'cookies'. Learn more