Abstract

The paper presents four 1-dimensional models of thermal resistance of walls in a heat exchanger with rectangular minichannels. The first model is the simplest one, with a single wall separating two fluids. The second model of the so called equivalent wall takes into account total volume of intermediate walls between layers of minichannels and of side walls of minichannels. The next two more complicated models take separately into account thermal resistance of these walls. In these two models side walls are treated as fins. The results of models comparison are presented. It is shown that thermal resistance may be neglected for metal walls but it should be taken into account for the walls made of plastics. For the case of non-neglected wall thermal resistance the optimum wall thickness was derived. Minichannel heat exchangers made of plastic are larger than those built of metal, but are significantly cheaper. It makes possible to use of such exchangers in inexpensive microscale ORC installations.

Go to article

Authors and Affiliations

Jarosław Mikielewicz
Witold Rybiński
Download PDF Download RIS Download Bibtex

Abstract

The image analysis consists in extracting from the information which is available to the observer of the part that is important from the perspective of the investigated process. This process usually accompanies a considerable reduction in the amount of information from the image. In the field of two-phase flows, computer image analysis can be used to determine flow and geometric parameters of flow patterns. This article presents the possibilities of using this method to determine the void fraction, vapor quality, bubble velocity and the geometric dimensions of flow patterns. The use of computer image analysis methods is illustrated by the example of HFE 7100 refrigerant methoxynonafluorobutane condensation in a glass tubular minichannel. The high speed video camera was used for the study, and the films and individual frames received during the study were analyzed.

Go to article

Authors and Affiliations

Małgorzata Sikora
Tadeusz Bohdal
Download PDF Download RIS Download Bibtex

Abstract

The numerical simulation of the heat transfer in the flow channels of the minichannel heat exchanger was carried out. The applied model was validated on the experimental stand of an air heat pump. The influence of louver heights was investigated in the range from 0 mm (plain fin) to 7 mm (maximum height). The set of simulations was prepared in Ansys CFX. The research was carried out in a range of air inlet velocities from 1 to 5 m/s. The values of the Reynolds number achieved in the experimental tests ranged from 93 to 486. The dimensionless factors, the Colburn factor and friction factor, were calculated to evaluate heat transfer and pressure loss, respectively. The effectiveness of each louver height was evaluated using the parameter that relates to the heat transfer and the pressure drop in the airflow. The highest value of effectiveness (1.53) was achieved by the louver height of 7 mm for the Reynolds number of around 290.
Go to article

Authors and Affiliations

Artur Romaniak
1
Michał Jan Kowalczyk
1
Marcin Łęcki
1
Artur Gutkowski
1
Grzegorz Górecki
1

  1. Lodz University of Technology, Zeromskiego 116, 90-924 Łódz, Poland
Download PDF Download RIS Download Bibtex

Abstract

The results of experimental investigations of heat transfer and a friction factor in an air channel of the minichannel heat exchanger are presented. The main aim of the analysis was to examine an influence of geometrical parameters of the fin shape with two geometries on heat transfer and flow characteristics of the air channel. The test rig was designed to monitor the parameters of the airflow during cooling by the minichannel heat exchanger. The analysis was conducted with the airflow in the range of 1–5 m/s. The temperature of the evaporation in a refrigeration system was set at 288.15 K. The energy balance of the refrigeration system was carried out. A numerical model describes the airflow through a part of the heat exchanger. Numerical simulations were validated with the experimental data. Numerical methods were used to evaluate the performance of the system and possibilities to improve the fin geometry. The characteristics of the friction factor (a measure of the pressure loss in the airflow) and the Colburn j-factor (heat transfer performance) were calculated. For the maximal velocity of the airflow, the Colburn factor was equal to 0.048 and the evaporator capacity equaled 1914 W.
Go to article

Bibliography

[1] Islam S., Islam M.S., Abedin M.Z.: Review on heat transfer enhancement by louvered fin. Int. J. Eng. Mater. Manufact. 6(2021), 60–80.
[2] Muszynski T., Kozieł S.M.: Parametric study of fluid flow and heat transfer over louvered fins of air heat pump evaporator. Arch. Thermodyn. 37(2016), 3, 45–62.
[3] Dodiya K., Bhatt N., Lai F.: Louvered fin compact heat exchanger: a comprehensive review. Int. J. Amb. Energ. (2020).
[4] Wan R., Wang Y., Kavtaradze R., Ji H., He X.: Research on the air-side thermal hydraulic performance of louvered fin and flat tube heat exchangers under low-pressure environment. Exp. Heat Transfer 33(2020), 1, 81–99.
[5] Gunnasegaran P., Shuaib N.H., Abdul Jalal M.F.: The effect of geometrical parameters on heat transfer characteristics of compact heat exchanger with louvered fins. ISRN Thermodyn. (2012), 1–10.
[6] Djamal H.D., Woon Q.Y., Suzairin M.S., Hisham Amirnordin S.: Effects of geometrical parameters to the performance of louvered fin heat exchangers. Appl. Mech. Mater. 773-774(2015), 398–402.
[7] Amirnordin S.H., Didane H.D., Norani Mansor M., Khalid A, Suzairin M.S., Raghavan V.R.: Pressure drop and heat transfer characteristics of louvered fin heat exchangers. Appl. Mech. Mater. 465-466(2014), 500–504.
[8] Chan Kang H., Jun G.W.: Heat transfer and flow resistance characteristics of louver fin geometry for automobile applications. J. Heat Transfer. 133(2011), 1–6.
[9] Okbaz A., Olcay A.B., Cellek M.S., Pinarbasi A.: Computational investigation of heat transfer and pressure drop in a typical louver fin-and-tube heat exchanger for various louver angles and fin pitches. EPJ Web Conf. 143(2017), 02084.
[10] Park J.S., Kim J., Lee K.S.: Thermal and drainage performance of a louvered fin heat exchanger according to heat exchanger inclination angle under frosting and defrosting conditions. Int. J. Heat Mass Transf. 108(2017), 1335–1339.
[11] Liu X., Chen H., Wang X., and Kefayati G.: Study on surface condensate water removal and heat transfer performance of a minichannel heat exchanger. Energies 13(2020), 5, 1065
[12] Saleem A., Kim M.H.: CFD analysis on the air-side thermal-hydraulic performance of multi-louvered fin heat exchangers at low Reynolds numbers. Energies 10(2017), 6, 1–24.
[13] Bohdal T., Charun H., Sikora M.: Heat transfer during condensation of refrigerants in tubular minichannels. Arch. Thermodyn. 33(2012), 2, 3–22.
[14] ASHRAE: ANSI/ASHRAE Standard 41.2-1987: Standard Methods for Air Velocity and Airflow Measurement (2018).
[15] Manual Ansys-CFX, Release 2020 R2. http://www.ansys.com (accessed 15 July 2020).
[16] Jasinski P.B., Kowalczyk M.J., Romaniak A., Warwas B., Obidowski D., Gutkowski A.: Investigation of thermal-flow characteristics of pipes with helical micro-fins of variable height. Energies 14(2021), 8, 2048.
[17] Kang, Hie-Chan & Jun, Gil.: Heat transfer and flow resistance characteristics of louver fin geometry for automobile applications. J. Heat Transf. 133 (2011), 101802.
Go to article

Authors and Affiliations

Michał Jan Kowalczyk
1
Marcin Łęcki
1
Artur Romaniak
1
Bartosz Warwas
1
Artur Gutkowski
1

  1. Lodz University of Technology, Institute of Turbomachinery, Wólczanska 217/221, 93-005 Łódz, Poland
Download PDF Download RIS Download Bibtex

Abstract

The paper describes issues related to pressure drop that accompanies the phenomenon of maldistribution of working fluid between the channels of a model minichannel plate heat exchanger. The research concerns a single exchanger’s plate containing 51 (in every geometry) parallel rectangular minichannels of hydraulic diameters 461 μm, 571 μm, 750 μm, and 823 μm. In addition, more complex geometry has been investigated, equipped with additional diagonal channels (so called extended geometry). The moment of the liquid phase transition through the heat exchanger was recorded at the flow rates ranging from 0.83 g/s to 13.33 g/s in the inlet manifold. The paper discusses the total pressure drop as a function of the flow rate and the characteristic dimension of minichannels, as well as the pressure drop as a function of the time of the fluid passage through the main part of the measuring section in which measurements were done. The resulting profiles correlate with the images of the flow distribution between channels recorded using the fast shutter speed camera, that allows to draw a further conclusions about the specifics of the maldistribution process. The impact of the total pressure drop on the actual range of optimum operating conditions of the heat exchanger was analyzed.
Go to article

Authors and Affiliations

Michał Klugmann
Paweł Dąbrowski
Dariusz Mikielewicz
Download PDF Download RIS Download Bibtex

Abstract

Gas-liquid two-phase flow in minichannels has been the subject of increased research interest in the past few years. Evaluation, however, of today's state of the art regarding hydrodynamics of flow in minichannels shows significant differences between existing test results. In the literature there is no clear information regarding: defining the boundary between minichannels and conventional channels, labelling of flow patterns. The review of literature on the hydrodynamics of gas-liquid flow in minichannels shows that, despite the fact that many research works have been published, the problem of determining the effect of diameter of the minichannel on the hydrodynamics of the flow is still at an early stage. Therefore, the paper presents the results of research concerning determination of flow regime map for the vertical upward flow in minichannels. The research is based on a comprehensive analysis of the literature data and on the research that has been carried out. Such approach to the mentioned above problems concerning key issues of the two-phase flow in minichannels allowed to determine ranges of occurrence of flow structures with a relatively high accuracy.

Go to article

Authors and Affiliations

Monika Wengel
Barbara Miłaszewicz
Roman Ulbrich
Download PDF Download RIS Download Bibtex

Abstract

Technology advancements entail a necessity to remove huge amounts of heat produced by today’s electronic devices based on highly integrated circuits, major generators of heat. Heat transfer to boiling liquid flowing through narrow minichannels is a modern solution to the problem of heat transfer enhancement. The study was conducted for FC-72 boiling in a rectangular, vertical and asymmetrically heated minichannel that had depths of 0.5-1.5 mm, a width of 20 mm and a length of 360 mm. The heat flux increased and decreased within the range of 58.3-132.0 kWm−2, the absolute pressure ranged from 0.116 to 0.184 MPa and the mass flux was 185-1139.2 kgm−2s−1. The boiling process took place on a flat vertical heating surface made of Haynes-230 0.1 mm thick acid-proof rolled plate with the surface roughness of 121 μm.

Go to article

Authors and Affiliations

Robert Kaniowski
Mieczysław Poniewski
Download PDF Download RIS Download Bibtex

Abstract

Analysis of the state of-the-art in research of minichannel heat exchangers, especially on the topic of flow maldistribution in multiple channels, has been accomplished. Studies on minichannel plate heat exchanger with 51 parallel minichannels with four hydraulic diameters, i.e., 461 μm, 574 μm, 667 μm, and 750 μm have been presented. Flow at the instance of filling the microchannel with water at low flow rates has been visualized. The pressure drop characteristics for single minichannel plate have been presented along with the channels blockage, which occurred in several cases. The impact of the mass flow rate and channels’ cross-section dimensions on the flow maldistribution were illustrated.

Go to article

Authors and Affiliations

Paweł Dąbrowski
Dariusz Mikielewicz
Michał Klugmann
Download PDF Download RIS Download Bibtex

Abstract

The aim of the study was the implementation of a numerical simulation of the air-water two-phase flow in the minichannel and comparing results obtained with the values obtained experimentally. To perform the numerical simulations commercial software ANSYS FLUENT 12 was used. The first step of the study was to reproduce the actual research installation as a three-dimensional model with appropriate and possible simplifications - future computational domain. The next step was discretisation of the computational domain and determination of the types of boundary conditions. ANSYS FLUENT 12 has three built-in basic models with which a two-phase flow can be described. However, in this work Volume-of-Fluid (VOF) model was selected as it meets the established requirements of research. Preliminary calculations were performed for a simplified geometry. The calculations were later verified whether or not the simplifications of geometry were chosen correctly and if they affected the calculation. The next stage was validation of the chosen model. After positive verification, a series of calculations was performed, in which the boundary conditions were the same as the starting conditions in laboratory experiments. A satisfactory description of the experimental data accuracy was attained.

Go to article

Authors and Affiliations

Jarosław Sowiński
Marek Krawczyk
Marek Dziubiński

This page uses 'cookies'. Learn more