Search results

Filters

  • Journals
  • Authors
  • Keywords
  • Date
  • Type

Search results

Number of results: 7
items per page: 25 50 75
Sort by:
Download PDF Download RIS Download Bibtex

Abstract

In this work microbiological air pollution at several commune sewage treatment plants (capacity up to 15,000 PE) was investigated. The bioreactors in all plants had a covered construction. The air samples were taken indoors as well as outdoors (both on the windward and leeward side) during different seasons. The samples were collected using the collision method. The presence of indicator organisms in the samples was determined according to the Polish Standards. Identification of individual indicators was performed on solid selective-differentiating substrates. To verify the presence of bacteria from Salmonella, Shigella, coliforms and enterococci species, the colonies observed on the MacConkey substrate were then sifted onto SS and Endo substrates. At all facilities (with one exception) the average CFU for the total number of bacteria and fungi did not exceed 1000/m3, which is the limit set by the Polish Standards for a pollution-free atmospheric air. Bacteria and fungi concentrations, observed at windward and leeward sides of all plants, were relatively low (<100 CFU/m3 and <1000 CFU/m3, respectively) and comparable. A sewage collection point had only a slight impact on the bioaerosol emission. The concentration of microorganisms in the immediate vicinity of covered reactors (aeration chambers) was rather low and remained below the limits sets by the Polish Standards at three facilities. The CFU of individual indicators, measured in rooms accessible for the personnel, was comparable to the CFU in technological rooms. However some indicators, e.g. a number of Actinomycetes, were significantly higher and reached >100 CFU/m3, which means significant air pollution. Similarly, the CFU of hemolytic bacteria had nonzero values. The only place where higher concentrations of bioaerosol were found was the centrifuge room, where digested sludge was dewatered. The number of fungi stayed below the limits there, but the amount of heterotrophic and hemolytic bacteria exceeded the limits and reached the values of ~10000 CFU/m3 and 800 CFU/m3, respectively; it means that the personnel working in this area is exposed to microbiological agents.

Go to article

Authors and Affiliations

Michał Polus
Zbigniew Mucha
Download PDF Download RIS Download Bibtex

Abstract

FA discharged from the wastewater treatment plant were extracted from purifi ed effl uents for the quantitative

and qualitative analysis. The treated sewage from municipal treatment plants was acidifi ed to pH <2 and extracted

with ion exchange resins in a laboratory column. After desorption with NH4

OH, the fulvic acids were condensed

under vacuum and tested for mass performance, UV-VIS light spectra, IR absorption spectra, elementary composition

and other elements. Their structure was analysed and compared to FA present in surface waters and in sewage treated

in other sewage treatment plants based on the authors’ own research and the literature data. The concentration of

FA in the treated sewage was 5.2 mg/L. There is a high interdependence between the IR spectrum analysis in the

visible light and the elementary composition of FA extracted from different environments, confi rming the conclusions

pertaining to the structure and properties of the acids being tested. The longer sewage is subjected to a biological

treatment process, the greater the degree of aromatic condensation and humus maturity of the FA contained within it.

FA contained in the sewage treated in the three biological sewage treatment plants have the ratio A2

/A3

(the ratio of the

absorbance of light with the wavelength of 250 and 300 nm) equal to the value 1.7. There is a high interdependence

between the IR spectrum analysis in the visible light and the elementary composition of FA extracted from different

environments, confi rming the conclusions pertaining to the structure and properties of the acids being tested.

Go to article

Authors and Affiliations

Anna Maria Anielak
Małgorzata Kryłów
Dominika Łomińska-Płatek
Download PDF Download RIS Download Bibtex

Abstract

Due to insufficient operation efficiency, the studied treatment plant has undergone modernization. The aim of this study was to assess whether this modernization improved quality of the STP effluent and water quality in the receiver. The research period of fifty months covered time before and after the modernization. Samples were collected in four sites – upstream and downstream of the STP and by the sewage discharge. Electrolytic conductivity, water temperature and pH were measured onsite. Chemical analyzes were based on ion chromatography and determined the concentration of NH4+, NO3-, NO2-, PO43-, TDS. Microbiological analysis comprised serial dilutions to assess the number of mesophilic and psychrophilic bacteria and membrane filtration to enumerate E. faecalis, total and fecal coliforms as well as total and fecal E. coli. Values of most analyzed parameters did not improve after the modernization, or improved for a very short period of time (NH4+), while some of them even increased, such as PO43-, total and thermotolerant coliforms and E. coli. The maximum value of thermotolerant E. coli reached nearly 7 million CFU/100 ml and was observed after modernization. Also at the sites situated downstream of the STP some of analyzed parameters increased. The conducted modernization did not improve the quality of treated sewage and even a further deterioration was observed. It could have been a result of rapidly growing number of tourists visiting the studied area, thus generating large amounts of sewage causing STP overload coupled with poor water and wastewater management. Significant percentage of unregistered tourists hinders proper assessment of the STP target efficiency.

Go to article

Authors and Affiliations

Anna Lenart-Boroń
Anna Bojarczuk
Łukasz Jelonkiewicz
Mirosław Żelazny
Download PDF Download RIS Download Bibtex

Abstract

The aim of the research was to determine the microbiological quality of atmospheric air in the Tuchów Sewage Treatment Plant, based on the presence of mesophilic bacteria, α- and β-hemolytic bacteria, actinomycetes and fungi. Bioaerosol measurements were made at four points (raw sewage inlet, aeration chamber, purifi ed sewage outlet and 150 m from the treatment plant, at the background point) in the period from January to December 2018. Bioaerosol samples were collected using Andersen’s 6-stage cascade impactor. The tested atmospheric air was characterized by a qualitatively and quantitatively diverse microfl ora. The highest amounts of all the studied groups of microorganisms were found at the raw sewage inlet, and in the case of actinomycetes, also twice in the place of biological purification. However, there were analyzes in which a higher concentration of microorganisms was observed outside the treatment plant at the control point constituting the background. This applies to bacteria and fungi. The largest source of emission of microorganisms to the atmosphere was the mechanical part of the sewage treatment plant (raw sewage inlet). The tested treatment plant may therefore contribute to the deterioration of the quality of the atmospheric air.

Go to article

Authors and Affiliations

Iwona B. Paśmionka
Download PDF Download RIS Download Bibtex

Abstract

Badania nad poziomym rozmieszczeniem makrozoobentosu piaszczystego dna w okolicach Jastarni i Juraty prowadzone były jednorazowo latem 2004 roku. Wyznaczono 15 stanowisk w okolicach Juraty dzieląc stanowiska na cztery promienie oddalone od siebie o 100 m oraz 4 stanowiska w pobliżu portu w Jastarni. Bezkręgowce denne na tym obszarze reprezentowane były przez 18 gatunków i 3 grupy ponadgatunkowe, które w pobliżu Juraty osiągały zagęszczenie X = 1840 osobn. · nr' i masę mokrą X = 121,8 g,,,,;m·', a w okolicach Jastarni x = 638 osobn.im? i x = 376,6 g,,,,,,·m·'. Najczęściej spotykanymi gatunkami były Hediste diversicolor, Cerastoderma g!aucum i Hydrobia u/vae. Większą bioróżnorodnością wyznaczoną wskaźnikiem ShannonaWienera charakteryzowały się stanowiska najbardziej oddalone od brzegu w Juracie. Skład gatunkowy oraz struktura jakościowo-ilościowa fauny dennej w tej części Zatoki Puckiej świadczy o niezadowalającym stanie środowiska oraz niskiej wartości tych obszarów jako miejsca żerowania ryb.
Go to article

Authors and Affiliations

Krystian Obolewski
Anna Jarosiewicz
Download PDF Download RIS Download Bibtex

Abstract

The aim of the research was the evaluation of wastewater management in terms of stability and efficiency of wastewater treatment, using statistical quality control. For this purpose, the analysis of the operation and operation of the “Kujawy” Sewage Treatment Plant was made, which is one of the most important and largest sewage management facilities in the city of Cracow. This assessment was done using control charts x for 59 observations. The analysed research period covered the multi-year from 2012 to 2016. Five key pollutant indicators were used to evaluate the work of the tested object: BOD5, CODCr, total suspension, total nitrogen and total phosphorus. In the case of the majority of them, based on the analysis of control charts, full stability of their removal was found in the tested sewage management facility. The exception was total nitrogen, for which periods of disturbed stability of its disposal processes were noted. Analysis of the effectiveness of wastewater treatment showed each time that the required efficiency of reduction of the analysed pollution indicators in the “Kujawy” Sewage Treatment Plant was achieved.

Go to article

Authors and Affiliations

Paulina Śliz
Download PDF Download RIS Download Bibtex

Abstract

The aim of the study was to model the operation of a wastewater treatment plant using the Monte Carlo method and selected probability distributions of random variables. Pollutant indices in treated wastewater were analysed, such as: biological oxygen demand ( BOD 5), chemical oxygen demand ( COD Cr), total suspended solids ( TSS), total nitrogen (N tot), total phosphorus (P tot). The preliminary analysis of pollution indicators series included the: calculation of descriptive statistics and assessment of biological degradability of wastewater. The consistency of the theoretical distributions with the empirical ones was assessed using Anderson–Darling statistics. The best-fitting statistical distributions were selected using the percent bias criterion. Based on the calculations performed, it was found that the analysed indicators of pollution in treated wastewater were characterised by an average variability of composition for BOD 5, COD Cr and TSS, and a high variability of composition for N tot and P tot. The best fitted distribution was log-normal for BOD 5, TSS, N tot and P tot and general extreme values for COD Cr. The simulation carried out using the Monte-Carlo method confirmed that there may be problems associated with the reduction of nutrients (N tot and P tot) the analysed wastewater treatment plant. Results of values obtained of the risk values of negative control of wastewater treatment plant operation for biogenic compounds, different from 1, indicate that the number of exceedances at the outflow may be higher than the acceptable one.
Go to article

Authors and Affiliations

Karolina Migdał
1
ORCID: ORCID
Agnieszka Operacz
1
ORCID: ORCID
Iryna Vaskina
2
ORCID: ORCID
Paulina Śliz
3
ORCID: ORCID
Jorge Tavares
4 5
ORCID: ORCID
Adelaide Almeida
4 5 6
ORCID: ORCID
Michał Migdał
7

  1. University of Agriculture in Krakow, Faculty of Environmental Engineering and Land Surveying, Department of Sanitary Engineering and Water Management, al. Mickiewicza 24/28, 30-059 Kraków, Poland
  2. Sumy State University, Faculty of Technical System and Energy Efficient Technologies, Department of Applied Ecology, Sumy, Ukraine
  3. Cracow University of Economics, Institute of Spatial Management and Urban Studies, Department of Spatial Management, Kraków, Poland
  4. Polytechnic Institute of Beja, Department of Technology and Applied Sciences, Beja, Portugal
  5. University of Beira Interior, Faculty of Engineering, Research Unit Fiber Materials and Environmental Technologies (FibEnTech-UBI), Covilhã, Portugal
  6. University Nova of Lisbon, Faculty of Science and Technology, Center for Environmental and Sustainability Research (CENSE), Lisbon, Portugal
  7. Stalprodukt S.A., Bochnia, Poland

This page uses 'cookies'. Learn more