Search results

Filters

  • Journals
  • Authors
  • Keywords
  • Date
  • Type

Search results

Number of results: 4
items per page: 25 50 75
Sort by:
Download PDF Download RIS Download Bibtex

Abstract

Due to urbanization, the population in the major cities in Malaysia is approximately 72.8% of its total population. The increase of population density has directly increased the amount of sewerage sludge waste that poses threat to the environment. In line with the green initiatives, alternative method to develop good quality concrete material from sewerage sludge waste can be further explored. Traditionally, sewerage sludge waste is processed using incinerator that require high energy and it is time consuming. In this study, microwave heating which require less energy consumption and less time consuming is used for sewerage sludge preparation. Prior to heating process, sewerage sludge waste is over dried at 105°C for 24 hours. Three types of microwave heating namely medium heating, medium high heating and high heating has been used. The chemical and physical properties microwaved sewerage sludge ash (MSSA) was tested using X-Ray Fluorescence (XRF), X-Ray Diffraction (XRD) and Scanning Electron Microscopy (SEM). Based on the result, the recommended temperature for the MSSA production for the concrete is High Mode Temperature. This is due to the result of MSSA for X-Ray Fluorescent test as its shows the highest in the content for pozzolanic element which are SiO2 and Fe2O3 that produce after the microwave burning process. The mineralogical composition and the crystalline phase of the High temperature MSSA due to X-Ray Diffraction test also shows high content of SiO2 as the major component as it is good for pozzolanic reaction in concrete. From the Scanning Electron Microscope test, it is observed that particle of High heated MSSAare slightly smaller than other temperature. Also, the densification occurs at High temperature MSSA. Hence, the optimal burning temperature mode for MSSA is High Mode temperature.
Go to article

Authors and Affiliations

Doh Shu Ing
1
ORCID: ORCID
Ramadhansyah Putra Jaya
1
ORCID: ORCID
Chia Min Ho
1
ORCID: ORCID
Siew Choo Chin
1
ORCID: ORCID
Marcin Nabiałek
2
ORCID: ORCID
Mohd Mustafa Al Bakri Abdullah
3
ORCID: ORCID
Sebastian Garus
4
ORCID: ORCID
Agata Śliwa
5
ORCID: ORCID

  1. College of Engineering, Universiti Malaysia Pahang, 26300 Gambang Kuantan Pahang, Malaysia
  2. Department of Physics, Czestochowa University of Technology, Poland
  3. Faculty of Chemical Engineering Technology, University Malaysia Perlis, Malaysia
  4. Faculty of Mechanical Engineering and Computer Science, Czestochowa University of Technology, Poland
  5. Division of Materials Processing Technology and Computer Techniques in Materials Science, Silesian 21 University of Technology, Poland
Download PDF Download RIS Download Bibtex

Abstract

Green roofs are increasingly popular in both new and modernised buildings. They significantly reduce the outflow of stormwater from buildings and change its composition. Wherever an urbanised area is equipped with a separate sewage system, usually stormwater goes directly to the receiver without treatment, which may affect the quality of water in the receiver. The article presents results of research carried out on the green roof of a building in Lodz, Poland. During rainfall, the flow rate from the roof was measured. With the use of the US EPA software Stormwater Management Model (SWMM) a model of the green roof was created and calibrated using rainfall data from the city’s pluviometric network. Based on the measurements of the roof runoff, as well as SWMM modelling, the degree of outfall reduction was determined. Samples of roof runoff were collected to study the characteristics of rainwater, including pH, electrical conductivity, organic compounds, nitrogen, phosphorus, and suspended solids. The results were compared with the quality of runoff from a traditional roof. Except ammonium nitrogen, values of the examined quality indicators was higher in the case of the green roof but the pollution load of almost all contaminants, except phosphorus, were lower due to a significant reduction in the volume of stormwater outflow (62–91%). The quality of stormwater discharged from the green roof improved with its age.
Go to article

Authors and Affiliations

Grażyna Sakson
1
ORCID: ORCID

  1. Lodz University of Technology, Institute of Environmental Engineering and Building Installations, Al. Politechniki 6, 90-924, Łódź, Poland

This page uses 'cookies'. Learn more