Search results

Filters

  • Journals
  • Authors
  • Keywords
  • Date
  • Type

Search results

Number of results: 2
items per page: 25 50 75
Sort by:
Download PDF Download RIS Download Bibtex

Abstract

Capacitive leakage and adjacent interference are the main influence sources of the measuring error in the traditional series step-up method. To solve the two problems, a new algorithm was proposed in this study based on a three-ports network. Considering the two influences, it has been proved that response of this three-ports network still has characteristics of linear superposition with this new algorithm. In this threeport network, the auxiliary series voltage transformers use a two-stage structure that can further decrease measurement uncertainty. The measurement uncertainty of this proposed method at 500/√3 kV is 6.8 ppm for ratio error and 7 μrad for phase displacement ( k = 2). This new method has also been verified by comparing its results with measurement results of the PTB in Germany over the same 110/√3 kV standard voltage transformer. According to test results, the error between the two methods was less than 2.7 ppm for ratio error and 2.9 μrad for phase displacement.
Go to article

Authors and Affiliations

Hao Liu
1 2
Lixue Chen
1
Xue Wang
2
Teng Yao
2
Xiong Gu
2

  1. State Key Laboratory of Advanced Electromagnetic Engineering and Technology, School of Electrical and Electronic Engineering, Huazhong University of Science and Technology, No. 1037 Luoyu Road Hongshan District, Wuhan, China
  2. China Electric Power Research Institute, Wuhan, China
Download PDF Download RIS Download Bibtex

Abstract

The objective of the paper is to analyse traceability issues in real-life gas flow measurements in complex distribution systems. The initial aim is to provide complete and traceable measurement results and calibration certificates of gas-flow meters, which correspond to specific installation conditions. Extensive work has been done to enable a more credible decision on how to deal in particular situations with the measurement uncertainty which is always subject of a flow meter’s calibration as a quantitative parameter value obtained in laboratory, and with the qualitative statement about the error of an outdoor meter. The laboratory simulation of a complex, real-life distributed system has been designed to achieve the initial aim. As an extension of standardized procedures that refer to the laboratory conditions, the proposed methods introduce additional “installation-specific” error sources. These sources could be either corrected (if identified) or considered as an additional “installation-specific” uncertainty contribution otherwise. The analysis and the results of the experimental work will contribute to more precise and accurate measurement results, thus assuring proper measurements with a known/estimated uncertainty for a specific gas flow installation. Also, the analysis will improve the existing normative documents by here presented findings, as well as fair trade in one of the most important and growing energy consumption areas regarding the legal metrology aspects. These facts will enable comparing the entire quantity of gas at the input of a complex distributed system with the cumulative sum of all individual gas meters in a specific installation.

Go to article

Authors and Affiliations

Zijad Džemić
Brane Širok
Janko Drnovšek

This page uses 'cookies'. Learn more